5.9 KiB
layout | title |
---|---|
documentation | ZW4005 / GE12722 - ZWave |
{% include base.html %}
ZW4005 / GE12722 On/Off Relay Switch
This describes the Z-Wave device ZW4005 / GE12722, manufactured by Jasco Products with the thing type UID of ge_zw4005_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZW4005 / GE12722 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Key Features
- Turn the connected device On/Off manually or via Z-Wave remote control
- May be used in single pole installation or with up to four GE model 12723 Add-on switches in 3, 4, 5 or 6-way wiring configurations
- Blue LED indicates switch location in a dark room
- Can be Included in multiple Groups and Scenes
- Supports Advanced Configuration; LED status, Invert switch (if unit is installed upside down)
- Screw Terminal installation; requires wiring connections for Line (Hot), Load, Neutral, and Ground.
- Traveler wire required for multi pole installation
- Use a standard-size wall plate for single gang installations (wall plate not included); Multi-gang box option available (removable ‘side wings’)
- Interchangeable Paddle switch: White & light almond paddle included in package
- LED can be enabled/disabled manually
- Inline traveler circuit protection
SPECIFICATIONS
- Power: 120 VAC, 60 Hz.
- Signal (Frequency): 908.42 MHz.
- Load ratings:
- Incandescent - Minimum Load: 40W, Maximum Load: 960W
- Motor – 1/2HP
- Resistive – 1800W
- Range: Up to 100 feet line of sight between the Wireless Controller and the closest Z-Wave receiver module.
Inclusion Information
Once the controller is ready to include your smart switch, press and release the top or bottom button on the smart switch to include it in the network.
Exclusion Information
Once the controller is ready to exclude your device, press and release the top or bottom button on the smart switch to exclude it from the network.
General Usage Information
Channels
The following table summarises the channels available for the ZW4005 / GE12722 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Switch
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Device Configuration
The following table provides a summary of the 2 configuration parameters available in the ZW4005 / GE12722. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | Night Light | Night Light |
4 | Invert Switch | Invert Switch |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 3: Night Light
Night Light Defines the behavior of the blue LED.
Default is Night Light mode where LED is on when switch is off. The following option values may be configured -:
Value | Description |
---|---|
0 | LED on when switch is OFF |
1 | LED on when switch is ON |
2 | LED always off |
The manufacturer defined default value is 0
(LED on when switch is OFF).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Invert Switch
Invert Switch Invert the ON/OFF Switch State. Setting this parameter to Yes will change the top of the switch to OFF and the bottom to ON.
Note: If you invert the switches and also install the product upside down, the load will now be control The following option values may be configured -:
Value | Description |
---|---|
0 | No |
1 | Yes |
The manufacturer defined default value is 0
(No).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_NODE_NAMING_V1 | |
COMMAND_CLASS_VERSION_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.