openhab-docs/_addons_bindings/zwave/doc/vision/zl7431_0_0.md

4.0 KiB

layout title
documentation ZL7431 - ZWave

{% include base.html %}

ZL7431 In Wall Relay Switch

This describes the Z-Wave device ZL7431, manufactured by Vision Security with the thing type UID of vision_zl7431_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZL7431 product image

The ZL7431 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Vision ZL7431US In-wall 1 relay switch

Inclusion Information

  • Turn on and turn off the wall switch that connects with ZL 7431 module 4 times to be included
  • (or press the Program SW 4 times within 2 seconds to be included),

then LED shall stop flashing. 

Exclusion Information

  • Turn on and turn off the wall switch that connects with ZL 7431 module 4 times to be excluded
  • (or press the Program SW 4 times within 2 seconds to be excluded),

then LED shall start flashing

Channels

The following table summarises the channels available for the ZL7431 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the ZL7431. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Indicator Light Indicator Light
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Indicator Light

Indicator Light

The following option values may be configured -:

Value Description
1 without Indicator Light
2 with Indicator Light

The manufacturer defined default value is 1 (without Indicator Light ).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZL7431 supports 1 association group.

Group 1: Update Controller

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.