RF9537 1000W Dimmer Light Switch
This describes the Z-Wave device RF9537, manufactured by Cooper Wiring Devices with the thing type UID of cooper_rf9537_00_000
.
This version of the device is limited to firmware versions below 3.4
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The RF9537 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
RF SMART DIMMER, for Incandescent/MLV Lighting Fixtures
Inclusion Information
Press the device switch one time to include it in the network, LED will stop blinking.
Exclusion Information
Press the device switch one time to exclude it in the network, LED will start blinking.
Channels
The following table summarises the channels available for the RF9537 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number | |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Alarm
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Device Configuration
The following table provides a summary of the 10 configuration parameters available in the RF9537. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Delayed OFF time | time in seconds to delay OFF |
2 | Panic ON time | Time in seconds for panic mode ON |
3 | Panic OFF time | time in seconds for OFF in panic mode |
4 | Basic Set Value | Send value to association group on trigger |
5 | Power Up State | Power Up State of the switch |
6 | Panic mode enable | Enables this switch to participate in panic mode |
7 | Dimmer Ramp Time | Time in seconds to reach desired level |
8 | Kickstart / Rapid Start | Turn on or off rapid start feature |
11 | Minimum Dimmer Level | The minimum dim level the switch will allow |
12 | Maximum Dimmer Level | The maximum dim level the switch will allow |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 1: Delayed OFF time
time in seconds to delay OFF The amount of time in seconds the switch will delay when trigger the delayed off feature Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Panic ON time
Time in seconds for panic mode ON The amount of time in seconds the switch will turn on for when panic mode is triggered Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Panic OFF time
time in seconds for OFF in panic mode The amount of time in seconds the switch will turn off for when panic mode is triggered Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Basic Set Value
Send value to association group on trigger Setting this to anything other than 0 will cause the value to be transmitted to devices in the association group when the switch is triggered. A setting other than 0 will likely result in undesired operation Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: Power Up State
Power Up State of the switch
The following option values may be configured -:
Value | Description |
---|---|
1 | Off |
2 | On |
3 | Last State |
The manufacturer defined default value is 1
(OFF).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 6: Panic mode enable
Enables this switch to participate in panic mode
The following option values may be configured -:
Value | Description |
---|---|
1 | Off |
2 | On |
The manufacturer defined default value is 1
(OFF).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Parameter 7: Dimmer Ramp Time
Time in seconds to reach desired level The amount of time in seconds the switch will take to reach the desired dim level Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Parameter 8: Kickstart / Rapid Start
Turn on or off rapid start feature Ensures that LED / CFL bulbs turn on when the preset dim level is low. Enabling this feature may cause the lights brightness to momentarily be bright when the switch is turned on before reducing in brightness to desired level The following option values may be configured -:
Value | Description |
---|---|
1 | Off |
2 | On |
The manufacturer defined default value is 1
(OFF).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Parameter 11: Minimum Dimmer Level
The minimum dim level the switch will allow
Values in the range 4 to 99 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Parameter 12: Maximum Dimmer Level
The maximum dim level the switch will allow
Values in the range 4 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The RF9537 supports 2 association groups.
Group 1: Group 1
Association group 1 supports 5 nodes.
Group 255: Group 255
Life line to the controller
Association group 255 supports 1 node.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_NODE_NAMING_V1 | |
COMMAND_CLASS_HAIL_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 |