ZMNHVD Flush Dimmer 0-10V
This describes the Z-Wave device ZMNHVD, manufactured by Goap with the thing type UID of qubino_zmnhvd_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZMNHVD supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Universal dimmer module with a standard 0-10V output and a multi-function input, which may be a push button / switch, a potentiometer or 0-10V signal
Inclusion Information
- press service button S for more than 2 second or
- press push button I1 three times within 3s (3 times change switch state within 3 seconds)
Exclusion Information
- press service button S for more than 6 second or
- press push button I1 five times within 3s ( 5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply
Channels
The following table summarises the channels available for the ZMNHVD -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Temperature Sensor | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Input I1 | sensor_general | sensor_general | Number |
Switch
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Temperature Sensor
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Input I1
The sensor_general
channel is of type sensor_general
and supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
Device Configuration
The following table provides a summary of the 24 configuration parameters available in the ZMNHVD. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Input 1 Switch Type | Input 1 Switch Type |
11 | Automatic turning off output after set time | |
12 | Automatic turning on output after set time | |
21 | Enable/Disable Double click function | |
30 | Saving the state after a power failure | |
52 | Auto or manual selection | |
53 | PID value inside deadband | |
54 | PID deadband | |
55 | Integral sampling time | |
56 | P parameter | |
57 | I parameter | |
58 | D parameter | Available config. parameters (data type is2 Byte DEC): |
60 | Minimum dimming value | |
61 | Maximum dimming value | |
65 | Dimming time (soft on/off) | |
66 | Dimming time when key pressed | |
67 | Ignore start level | |
68 | Dimming duration | |
110 | Temperature sensor offset settings | |
120 | Digital temperature sensor reporting | |
140 | Input I1 Sensor reporting | |
141 | Input I1 0-10V reporting threshold | |
143 | Minimum sensor range value | |
144 | Maximum sensor range value | |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 1: Input 1 Switch Type
Input 1 Switch Type By this parameter the user can set input based on device type (switch, potentiometer, 0-10V sensor,...) The following option values may be configured -:
Value | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | Bi-stable switch type |
2 | Potentiometer |
3 | Temperature sensor |
4 | Illumination sensor |
5 | General purpose sensor |
The manufacturer defined default value is 0
(mono-stable switch type (push button)).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 11: Automatic turning off output after set time
Values in the range 0 to 32536 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_2
and is of type INTEGER
.
Parameter 12: Automatic turning on output after set time
Values in the range 0 to 32535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_12_2
and is of type INTEGER
.
Parameter 21: Enable/Disable Double click function
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
Parameter 30: Saving the state after a power failure
The following option values may be configured -:
Value | Description |
---|---|
0 | Module saves it state |
1 | Module turns OFF |
The manufacturer defined default value is 0
(Module saves it state).
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Parameter 52: Auto or manual selection
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_52_1
and is of type INTEGER
.
Parameter 53: PID value inside deadband
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_53_1
and is of type INTEGER
.
Parameter 54: PID deadband
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_54_1
and is of type INTEGER
.
Parameter 55: Integral sampling time
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_55_1
and is of type INTEGER
.
Parameter 56: P parameter
Values in the range 0 to 1000 may be set.
The manufacturer defined default value is 100
.
This parameter has the configuration ID config_56_2
and is of type INTEGER
.
Parameter 57: I parameter
Values in the range 0 to 1000 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_57_2
and is of type INTEGER
.
Parameter 58: D parameter
Available config. parameters (data type is2 Byte DEC):
Values in the range 0 to 1000 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_58_2
and is of type INTEGER
.
Parameter 60: Minimum dimming value
Values in the range 1 to 98 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_60_1
and is of type INTEGER
.
Parameter 61: Maximum dimming value
Values in the range 2 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_61_1
and is of type INTEGER
.
Parameter 65: Dimming time (soft on/off)
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 100
.
This parameter has the configuration ID config_65_2
and is of type INTEGER
.
Parameter 66: Dimming time when key pressed
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_66_1
and is of type INTEGER
.
Parameter 67: Ignore start level
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_67_1
and is of type INTEGER
.
Parameter 68: Dimming duration
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_68_1
and is of type INTEGER
.
Parameter 110: Temperature sensor offset settings
Values in the range 1 to 32536 may be set.
The manufacturer defined default value is 32536
.
This parameter has the configuration ID config_110_2
and is of type INTEGER
.
Parameter 120: Digital temperature sensor reporting
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_120_1
and is of type INTEGER
.
Parameter 140: Input I1 Sensor reporting
Values in the range 0 to 140 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_140_2
and is of type INTEGER
.
Parameter 141: Input I1 0-10V reporting threshold
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_141_1
and is of type INTEGER
.
Parameter 143: Minimum sensor range value
Values in the range 0 to 20000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_143_2
and is of type INTEGER
.
Parameter 144: Maximum sensor range value
Values in the range 0 to 20000 may be set.
The manufacturer defined default value is 1000
.
This parameter has the configuration ID config_144_2
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZMNHVD supports 6 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Reserved for communication with the main controller
Association group 1 supports 1 node.
Group 2: basic on/off
triggered at change of the input I1 state and reflecting its state
Association group 2 supports 16 nodes.
Group 3: start level change/stop level change
triggered at change of the input I1 state and reflecting its state) up to 16 nodes. Working only when the Parameter no. 1 is set to mono stable switch type.
Association group 3 supports 16 nodes.
Group 4: multilevel set
triggered at changes of state/value of the Flush Dimmer 0-10V
Association group 4 supports 16 nodes.
Group 5: multilevel sensor report - analogue sensor
triggered at change of analogue sensor
Association group 5 supports 16 nodes.
Group 6: multilevel sensor report - temperature sensor
triggered at change of temperature sensor
Association group 6 supports 16 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1 |