4.6 KiB
layout | title |
---|---|
documentation | 009501 - ZWave |
{% include base.html %}
009501 Popp 09501 Flow Stop
This describes the Z-Wave device 009501, manufactured by Popp & Co with the thing type UID of popp_009501_01_006
.
This version of the device is limited to firmware versions above 1.6
The device is in the category of HVAC, defining Air condition devices, Fans.
The 009501 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
No device information is provided in the database. Consider updating the database to improve the documentation.
Channels
The following table summarises the channels available for the 009501 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Switch
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Device Configuration
The following table provides a summary of the 2 configuration parameters available in the 009501. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
0 | LED Status | No help available, self explanatory.... |
1 | Shut-off controller behavior | The parameter defines how to control the shut-off controller. |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 0: LED Status
No help available, self explanatory....
0: LED always ON (Only on operation OFF)
1: LED always OFF (Only on operation ON)
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_0_1
and is of type INTEGER
.
Parameter 1: Shut-off controller behavior
The parameter defines how to control the shut-off controller.
0: Remote and manually open/close
1: Remote open/close only
2: Only remote open; only manually closing
3: Only manually open; only remote closing
4: Manually open/close only
Values in the range 0 to 4 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 009501 supports 2 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 10 nodes.
Group 2: Local Valve Operation
Association group 2 supports 10 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |