openhab-docs/_addons_bindings/zwave/doc/popp/009501_1_6.md

4.6 KiB

layout title
documentation 009501 - ZWave

{% include base.html %}

009501 Popp 09501 Flow Stop

This describes the Z-Wave device 009501, manufactured by Popp & Co with the thing type UID of popp_009501_01_006. This version of the device is limited to firmware versions above 1.6

The device is in the category of HVAC, defining Air condition devices, Fans.

009501 product image

The 009501 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the 009501 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the 009501. Detailed information on each parameter can be found in the sections below.

Param Name Description
0 LED Status No help available, self explanatory....
1 Shut-off controller behavior The parameter defines how to control the shut-off controller.
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 0: LED Status

No help available, self explanatory.... 0: LED always ON (Only on operation OFF)
1: LED always OFF (Only on operation ON) Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_0_1 and is of type INTEGER.

Parameter 1: Shut-off controller behavior

The parameter defines how to control the shut-off controller. 0: Remote and manually open/close
1: Remote open/close only
2: Only remote open; only manually closing
3: Only manually open; only remote closing
4: Manually open/close only Values in the range 0 to 4 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 009501 supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 10 nodes.

Group 2: Local Valve Operation

Association group 2 supports 10 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.