openhab-docs/_addons_bindings/zwave/doc/philio/pan061a_1_13.md

7.5 KiB

layout title
documentation PAN06 - ZWave

{% include base.html %}

PAN06 In Wall Dual Relay (1 Way) Switch Module 2x 1.5kW

This describes the Z-Wave device PAN06, manufactured by Philio Technology Corp with the thing type UID of philio_pan061a_01_013. This version of the device is limited to firmware versions above 1.13

The PAN06 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the PAN06 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Alarm alarm_general alarm_general Alarm Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Switch 2 switch_binary2 switch_binary Switch Switch
Switch 3 switch_binary3 switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Switch 1

Switch the power on and off.

The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Switch 2

Switch the power on and off.

The switch_binary2 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Switch 3

Switch the power on and off.

The switch_binary3 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 6 configuration parameters available in the PAN06. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Selected endpoint If Controller not using Multi_Channel command class to access the endpoint of PAN06, you may configure the endpoint value to react the Basic Command Class
2 Switch mode Change the external switch mode
3 Restore switch state mode
4 Auto Off Timer
5 RF Off command mode
6 Endpoint 3 Exists
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Selected endpoint

If Controller not using Multi_Channel command class to access the endpoint of PAN06, you may configure the endpoint value to react the Basic Command Class

The following option values may be configured -:

Value Description
1 Relay 1
2 Relay 2
3 Relay 1 + 2

The manufacturer defined default value is 3 (Relay 1 + 2).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Switch mode

Change the external switch mode

The following option values may be configured -:

Value Description
1 Edge mode
2 Pulse mode
3 Edge-Toggle mode

The manufacturer defined default value is 1 (Edge mode).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Restore switch state mode

The following option values may be configured -:

Value Description
0 Switch Off
1 Last State
2 Switch On

The manufacturer defined default value is 1 (Last State).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Auto Off Timer

Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: RF Off command mode

The following option values may be configured -:

Value Description
0 Switch Off
1 Ignore
2 Switch Toggle
3 Switch On

The manufacturer defined default value is 0 (Switch Off).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Endpoint 3 Exists

The following option values may be configured -:

Value Description
1 Yes
2 No

The manufacturer defined default value is 0.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PAN06 supports 3 association groups.

Group 1: Relay 1 + 2

Association group 1 supports 1 node.

Group 2: Relay 1

Association group 2 supports 1 node.

Group 3: Relay 2

Association group 3 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.