SHMK10000 Magnetic Contact

This describes the Z-Wave device SHMK10000, manufactured by *ABUS Security-Center GmbH & Co. KG * with the thing type UID of abus_shmk10000_00_000.

The device is in the category of Door, defining Door sensors.

SHMK10000 product image

The SHMK10000 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The SHMK10000 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

The ABUS Z-Wave SHMK10000...

  • is a battery-operated radio magnetic contact
  • is Z-Wave PLUS compatible & certified
  • supports the Z-Wave S2 Standard (Security 2)
  • detects opening/closing by removing sensor and magnet
  • detects tampering when the housing is opened
  • has a battery-empty warning function
  • was developed for indoor installation

Inclusion Information

  • Slide the base unit from the mounting plate and remove the safety strip from the battery compartment
  • Click the + (Add) button in your Z-Wave App and follow the further instructions
  • Press the Tamper-button 3 times within 1.5 seconds and the Status-LED on the base unit front will flash 3 times

The App will show if the Add device process was successful and the Status-LED will turn off Repeat the inclusion process from step B if it was not successful.

Exclusion Information

  • Click the - (Remove) button in your Z-Wave App and follow the further instructions Press the Tamper-button 3 times within 1.5 seconds and the Status-LED on the base unit front will flash 3 times

The App will show if the Remove device process was successful and the Status-LED on device will flash 6 times Repeat the exclusion process from step A if it was not successful.

Wakeup Information

The SHMK10000 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Press the Tamper-button 3 times within 1.5 seconds and the Status-LED on the base unit front will flash 3 times

General Usage Information

Channels

The following table summarises the channels available for the SHMK10000 -:

Channel Name Channel ID Channel Type Category Item Type
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Door Sensor sensor_door sensor_door Door Contact
Battery Level battery-level system.battery_level Battery Number

Alarm (burglar)

Indicates if the burglar alarm is triggered.

The alarm_burglar channel is of type alarm_burglar and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Door Sensor

Indicates if the door/window is open or closed.

The sensor_door channel is of type sensor_door and supports the Contact item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Contact item type -:

Value Label
OPEN Open
CLOSED Closed

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The SHMK10000 supports 5 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline association group includes command classes: Battery report, Notification report, Device Reset Locally notification and Binary report.

Association group 1 supports 5 nodes.

Group 2: Binary Sensor (Door)

Binary Sensor Command Class Root Device group(Binary Sensor) Binary Sensor Command Class:Compatible with 300 series

  1. Binary Sensor reports status of open or close door via Lifeline.
  2. When the sensor detects status change between close door and open door, the device will be triggered.

Association group 2 supports 5 nodes.

Group 3: Binary Sensor (Tamper)

Binary Sensor Command Root Device group(Binary Sensor) Binary Sensor Command Class:Compatible with 300 series 

  1. Binary Sensor reports the removed status of door sensor. 
  2. When the sensor detects status change of tamper, the device will be triggered

Association group 3 supports 5 nodes.

Group 4: Notification 1

Notification report open door or close status via Lifeline Root Device group(Notification)

  1. Notification report open door or close status via Lifeline.
  2. When the sensor detects status change between close
    door and open door, the device will be triggered.

Association group 4 supports 5 nodes.

Group 5: Notification 2

Binary Sensor reports the removed status of door sensor Root Device group(Notification) 

  1. Binary Sensor reports the removed status of door sensor. 
  2. When the sensor detects status change of tamper, the device will be triggered.

Association group 5 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V1 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V2