SHHA10000 Smart Plug, Power Switch

This describes the Z-Wave device SHHA10000, manufactured by *ABUS Security-Center GmbH & Co. KG * with the thing type UID of abus_shhm10000_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

SHHA10000 product image

The SHHA10000 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The SHHA10000 was developed for use in home automation systems that use the Z-Wave wireless standard. The power outlet enables you to switch a large number of your electronic devices - conveniently and directly via the gateway's app or automatically according to an individual schedule. In conjunction with configurable scenes, a large number of smart functions can be initiated, e.g. a presence simulation or you can preheat the coffee machine before getting up.

The ABUS Z-Wave SHHA10000...:

  • is a wireless socket
  • is Z-Wave PLUS compatible & certified
  • supports the Z-Wave S2 Standard (Security 2)
  • measures your (current) consumption values reliably over any period of time
  • detects applied mains voltage, wattage consumption, kWh and ampere
  • can be switched on and off via app or manually
  • was developed for indoor installation

Inclusion Information

  1. Plug the Wireless-Socket into an outlet. The StatusLED is flashing.
  2. Click the + (Add) button in your Z-Wave App and follow the further instructions
  3. Press the Network-Button on the Socket once The App will show if the Add device process was successful The Status LED does not flash anymore but indicates if device is switched on or off Repeat the inclusion process if it was not successful.

Exclusion Information

  1. Click the - (Remove) button in your Z-Wave App and follow the further instructions
  2. Press the Button on the socket 3 times The App will show if the Remove Device process was successful. The Status-LED will now flash continuously Repeat the exclusion process if it was not successful.

General Usage Information

Switch the Wireless Socket either via the integrated button or once connected to a Z-Wave Gateway via App Status-LED is on = Wireless Socket is switched on Status-LED is off = Wireless Socket is switched off Never connect wireless Sockets in series! The Wireless-Socket must be easily accessible

Channels

The following table summarises the channels available for the SHHA10000 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 12 configuration parameters available in the SHHA10000. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Overvoltage protection Enable / Disable overvoltage protection.
2 Device status after power failure Set which device status should be present after a power failure.
3 Device status report Device status report when device status changes.
4 LED indicator Behaviour of the LED display with device status "On".
16 Power report (Threshold) The threshold value serves as an additional condition for the time-based report.
17 Power report (Threshold value in percent) The threshold value serves as an additional condition for the time-based report.
100 Reset 101 104 Resets parameter 101 - 104 to factory setting.
101 Power report (Time) The interval time of the power report (W).
102 Consumption report (Time) The interval time of the consumption report (kWh).
103 Voltage report (Time) The interval time of the voltage report (V).
104 Current report (Time) The interval time of the current report (A).
254 Enable / Disable Configuration Enables / Disables the configuration.

Parameter 1: Overvoltage protection

Enable / Disable overvoltage protection. Enable / Disable overvoltage protection.

  • 0 = Disabled
  • 1 = Enabled

(Hexadecimal: 0x00 0x01) The following option values may be configured -:

Value Description
0 disable
1 enable

The manufacturer defined default value is 1 (enable).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Device status after power failure

Set which device status should be present after a power failure. Set which device status should be present after a power failure.

  • 0 = Status before power failure
  • 1 = Status “on”
  • 2 = Status “off”

(Hexadezimal: 0x00 0x02) The following option values may be configured -:

Value Description
0 Status before power failure
1 Status “on”
2 Status “off”

The manufacturer defined default value is 0 ( Status before power failure).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Device status report

Device status report when device status changes. Device status report when device status changes.

  • 0 = Disabled
  • 1 = Send report
  • 2 = Send report only with manual change

(Hexadezimal: 0x00 0x02) The following option values may be configured -:

Value Description
0 Disabled
1 Send report
2 Send report only with manual change

The manufacturer defined default value is 1 (Send report).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: LED indicator

Behaviour of the LED display with device status "On". Behaviour of the LED display with device status "On".

  • 0 = LED is permanently active with device status "On
  • 1 = LED is active for 5 seconds when changing to device status "On" and then extinguishes

(Hexadezimal: 0x00 0x01) The following option values may be configured -:

Value Description
0 LED is permanently active with device status "On"
1 LED is active for 5 seconds

The manufacturer defined default value is 0 (LED is permanently active with device status "On").

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 16: Power report (Threshold)

The threshold value serves as an additional condition for the time-based report. The threshold value serves as an additional condition for the time-based report.
If the threshold value was not exceeded, the time-based report is not sent.
The value 0 deactivates the power report threshold.

  • Adjustable from 0 65535 in Watt

(Hexadecimal: 0x00 0xFFFF) Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_16_2 and is of type INTEGER.

Parameter 17: Power report (Threshold value in percent)

The threshold value serves as an additional condition for the time-based report. The threshold value serves as an additional condition for the time-based report.
If the threshold value was not exceeded, the time-based report is not sent.
The value 0 deactivates the power report threshold.

  • Adjustable from 0 127 in Watt

(Hexadecimal: 0x00 0x7F) Values in the range 0 to 127 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_17_1 and is of type INTEGER.

Parameter 100: Reset 101 104

Resets parameter 101 - 104 to factory setting. 84 = Resets parameter 101 - 104 to factory setting. Values in the range 84 to 84 may be set.

The manufacturer defined default value is 84.

This parameter has the configuration ID config_100_1 and is of type INTEGER.

Parameter 101: Power report (Time)

The interval time of the power report (W). The interval time of the power report (W).
The value 0 disables the report.

  • Adjustable from 5 - 2678400 in seconds

(Hexadecimal: 0x00 - 0x28DE80) Values in the range 5 to 2678400 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_101_4 and is of type INTEGER.

Parameter 102: Consumption report (Time)

The interval time of the consumption report (kWh). The interval time of the consumption report (kWh).
The value 0 disables the report.

  • Adjustable from 5 - 2678400 in seconds

(Hexadecimal: 0x00 - 0x28DE80) Values in the range 5 to 2678400 may be set.

The manufacturer defined default value is 3600.

This parameter has the configuration ID config_102_4 and is of type INTEGER.

Parameter 103: Voltage report (Time)

The interval time of the voltage report (V). The interval time of the voltage report (V).
The value 0 disables the report.

  • Adjustable from 5 - 2678400 in seconds

(Hexadecimal: 0x00 - 0x28DE80) Values in the range 5 to 2678400 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_103_4 and is of type INTEGER.

Parameter 104: Current report (Time)

The interval time of the current report (A). The interval time of the current report (A).
The value 0 disables the report.

  • Adjustable from 5 - 2678400 in seconds

(Hexadecimal: 0x00 - 0x28DE80) Values in the range 5 to 2678400 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_104_4 and is of type INTEGER.

Parameter 254: Enable / Disable Configuration

Enables / Disables the configuration. Enables / Disables the configuration.

  • 0 = Configuration is enabled
  • 1 = Configuration is disabled

(Hexadecimal: 0x00 - 0x01) The following option values may be configured -:

Value Description
0 Configuration enabled
1 Configuration disabled

The manufacturer defined default value is 0 (Configuration enabled).

This parameter has the configuration ID config_254_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The SHHA10000 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Sending Meter Report When the state of Smart Plug (turn on or off the load) is changed:

  1. Set Configuration parameter 3 to 0 (0x00): Do not send Basic Report
  2. Set Configuration parameter 3 to 1 (0x00): Send Basic Report
  3. Set Configuration parameter 3 to 2 (0x00): Send Basic Report only when Load condition is changed not by Z-WAVE Command, such as short pressing.

Sending Meter Report.

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SECURITY_V1