SHHA10000 Smart Plug, Power Switch
This describes the Z-Wave device SHHA10000, manufactured by *ABUS Security-Center GmbH & Co. KG * with the thing type UID of abus_shhm10000_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The SHHA10000 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
The SHHA10000 was developed for use in home automation systems that use the Z-Wave wireless standard. The power outlet enables you to switch a large number of your electronic devices - conveniently and directly via the gateway's app or automatically according to an individual schedule. In conjunction with configurable scenes, a large number of smart functions can be initiated, e.g. a presence simulation or you can preheat the coffee machine before getting up.
The ABUS Z-Wave SHHA10000...:
- is a wireless socket
- is Z-Wave PLUS compatible & certified
- supports the Z-Wave S2 Standard (Security 2)
- measures your (current) consumption values reliably over any period of time
- detects applied mains voltage, wattage consumption, kWh and ampere
- can be switched on and off via app or manually
- was developed for indoor installation
Inclusion Information
- Plug the Wireless-Socket into an outlet. The StatusLED is flashing.
- Click the + (Add) button in your Z-Wave App and follow the further instructions
- Press the Network-Button on the Socket once The App will show if the Add device process was successful The Status LED does not flash anymore but indicates if device is switched on or off Repeat the inclusion process if it was not successful.
Exclusion Information
- Click the - (Remove) button in your Z-Wave App and follow the further instructions
- Press the Button on the socket 3 times The App will show if the Remove Device process was successful. The Status-LED will now flash continuously Repeat the exclusion process if it was not successful.
General Usage Information
Switch the Wireless Socket either via the integrated button or once connected to a Z-Wave Gateway via App Status-LED is on = Wireless Socket is switched on Status-LED is off = Wireless Socket is switched off Never connect wireless Sockets in series! The Wireless-Socket must be easily accessible
Channels
The following table summarises the channels available for the SHHA10000 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Scene Number | scene_number | scene_number | Number | |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Switch
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Electric meter (amps)
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (volts)
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (kWh)
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (watts)
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Device Configuration
The following table provides a summary of the 12 configuration parameters available in the SHHA10000. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Overvoltage protection | Enable / Disable overvoltage protection. |
2 | Device status after power failure | Set which device status should be present after a power failure. |
3 | Device status report | Device status report when device status changes. |
4 | LED indicator | Behaviour of the LED display with device status "On". |
16 | Power report (Threshold) | The threshold value serves as an additional condition for the time-based report. |
17 | Power report (Threshold value in percent) | The threshold value serves as an additional condition for the time-based report. |
100 | Reset 101 – 104 | Resets parameter 101 - 104 to factory setting. |
101 | Power report (Time) | The interval time of the power report (W). |
102 | Consumption report (Time) | The interval time of the consumption report (kWh). |
103 | Voltage report (Time) | The interval time of the voltage report (V). |
104 | Current report (Time) | The interval time of the current report (A). |
254 | Enable / Disable Configuration | Enables / Disables the configuration. |
Parameter 1: Overvoltage protection
Enable / Disable overvoltage protection. Enable / Disable overvoltage protection.
- 0 = Disabled
- 1 = Enabled
(Hexadecimal: 0x00 – 0x01) The following option values may be configured -:
Value | Description |
---|---|
0 | disable |
1 | enable |
The manufacturer defined default value is 1
(enable).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Device status after power failure
Set which device status should be present after a power failure. Set which device status should be present after a power failure.
- 0 = Status before power failure
- 1 = Status “on”
- 2 = Status “off”
(Hexadezimal: 0x00 – 0x02) The following option values may be configured -:
Value | Description |
---|---|
0 | Status before power failure |
1 | Status “on” |
2 | Status “off” |
The manufacturer defined default value is 0
( Status before power failure).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Device status report
Device status report when device status changes. Device status report when device status changes.
- 0 = Disabled
- 1 = Send report
- 2 = Send report only with manual change
(Hexadezimal: 0x00 – 0x02) The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Send report |
2 | Send report only with manual change |
The manufacturer defined default value is 1
(Send report).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: LED indicator
Behaviour of the LED display with device status "On". Behaviour of the LED display with device status "On".
- 0 = LED is permanently active with device status "On
- 1 = LED is active for 5 seconds when changing to device status "On" and then extinguishes
(Hexadezimal: 0x00 – 0x01) The following option values may be configured -:
Value | Description |
---|---|
0 | LED is permanently active with device status "On" |
1 | LED is active for 5 seconds |
The manufacturer defined default value is 0
(LED is permanently active with device status "On").
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 16: Power report (Threshold)
The threshold value serves as an additional condition for the time-based report.
The threshold value serves as an additional condition for the time-based report.
If the threshold value was not exceeded, the time-based report is not sent.
The value 0 deactivates the power report threshold.
- Adjustable from 0 – 65535 in Watt
(Hexadecimal: 0x00 – 0xFFFF) Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_16_2
and is of type INTEGER
.
Parameter 17: Power report (Threshold value in percent)
The threshold value serves as an additional condition for the time-based report.
The threshold value serves as an additional condition for the time-based report.
If the threshold value was not exceeded, the time-based report is not sent.
The value 0 deactivates the power report threshold.
- Adjustable from 0 – 127 in Watt
(Hexadecimal: 0x00 – 0x7F) Values in the range 0 to 127 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
Parameter 100: Reset 101 – 104
Resets parameter 101 - 104 to factory setting. 84 = Resets parameter 101 - 104 to factory setting. Values in the range 84 to 84 may be set.
The manufacturer defined default value is 84
.
This parameter has the configuration ID config_100_1
and is of type INTEGER
.
Parameter 101: Power report (Time)
The interval time of the power report (W).
The interval time of the power report (W).
The value 0 disables the report.
- Adjustable from 5 - 2678400 in seconds
(Hexadecimal: 0x00 - 0x28DE80) Values in the range 5 to 2678400 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_101_4
and is of type INTEGER
.
Parameter 102: Consumption report (Time)
The interval time of the consumption report (kWh).
The interval time of the consumption report (kWh).
The value 0 disables the report.
- Adjustable from 5 - 2678400 in seconds
(Hexadecimal: 0x00 - 0x28DE80) Values in the range 5 to 2678400 may be set.
The manufacturer defined default value is 3600
.
This parameter has the configuration ID config_102_4
and is of type INTEGER
.
Parameter 103: Voltage report (Time)
The interval time of the voltage report (V).
The interval time of the voltage report (V).
The value 0 disables the report.
- Adjustable from 5 - 2678400 in seconds
(Hexadecimal: 0x00 - 0x28DE80) Values in the range 5 to 2678400 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_103_4
and is of type INTEGER
.
Parameter 104: Current report (Time)
The interval time of the current report (A).
The interval time of the current report (A).
The value 0 disables the report.
- Adjustable from 5 - 2678400 in seconds
(Hexadecimal: 0x00 - 0x28DE80) Values in the range 5 to 2678400 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_104_4
and is of type INTEGER
.
Parameter 254: Enable / Disable Configuration
Enables / Disables the configuration. Enables / Disables the configuration.
- 0 = Configuration is enabled
- 1 = Configuration is disabled
(Hexadecimal: 0x00 - 0x01) The following option values may be configured -:
Value | Description |
---|---|
0 | Configuration enabled |
1 | Configuration disabled |
The manufacturer defined default value is 0
(Configuration enabled).
This parameter has the configuration ID config_254_1
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The SHHA10000 supports 1 association group.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Sending Meter Report When the state of Smart Plug (turn on or off the load) is changed:
- Set Configuration parameter 3 to 0 (0x00): Do not send Basic Report
- Set Configuration parameter 3 to 1 (0x00): Send Basic Report
- Set Configuration parameter 3 to 2 (0x00): Send Basic Report only when Load condition is changed not by Z-WAVE Command, such as short pressing.
Sending Meter Report.
Association group 1 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 |