Trane XR524 Touchscreen Comfort Control Thermostat
This describes the Z-Wave device Trane XR524, manufactured by Trane Corporation with the thing type UID of trane_xr524_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The Trane XR524 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
The Trane 524 Touchscreen Comfort Control is compatible with single and multistage forced air systems, including:
- Gas furnace systems
- Oil furnace systems
- Electric furnace systems
- Heat pump systems
- Air conditioning systems
Inclusion Information
- Press MENU on the 524 Control.
- Press NEXT to advance to the Z-WAVE menu.
- Press SELECT
Exclusion Information
- Press MENU on the 524 Control.
- Press NEXT to scroll to Z-WAVE screen then press SELECT.
- Press YES to exclude the control
Channels
The following table summarises the channels available for the Trane XR524 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | thermostat_state | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Thermostat fan mode | thermostat_fanmode | thermostat_fanmode | ||
Thermostat fan state | thermostat_fanstate | thermostat_fanstate |
Sensor (temperature)
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Thermostat mode
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Operating State
Sets the thermostat operating state.
The thermostat_state
channel is of type thermostat_state
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Setpoint (heating)
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Setpoint (cooling)
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Thermostat fan mode
Channel type information on this channel is not found.
Thermostat fan state
Channel type information on this channel is not found.
Device Configuration
The following table provides a summary of the 59 configuration parameters available in the Trane XR524. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | System Type | System Type |
2 | Fan Type | Fan Type |
3 | Change Over Type | Change Over Type |
4 | Units | Units |
9 | Display Lock | Display Lock |
10 | Minimum Off Time | Minimum Off Time |
11 | Minimum Run Time | Minimum Run Time |
12 | Heating Delta Stage 1 ON | Heating Delta Stage 1 ON |
13 | Heating Delta Stage 1 OFF | Heating Delta Stage 1 OFF |
14 | Heating Delta Stage 2 ON | Heating Delta Stage 2 ON |
15 | Heating Delta Stage 2 OFF | Heating Delta Stage 2 OFF |
16 | Heating Delta Stage 3 ON | Heating Delta Stage 3 ON |
17 | Heating Delta Stage 3 OFF | Heating Delta Stage 3 OFF |
18 | Cooling Delta Stage 1 ON | Cooling Delta Stage 1 ON |
19 | Cooling Delta Stage 1 OFF | Cooling Delta Stage 1 OFF |
20 | Cooling Delta Stage 2 ON | Cooling Delta Stage 2 ON |
21 | Cooling Delta Stage 2 OFF | Cooling Delta Stage 2 OFF |
24 | H/C Delta | H/C Delta |
25 | SetBack Mode | SetBack Mode |
29 | ESM Setpoint--Heating | ESM Setpoint--Heating |
30 | ESM Setpoint--Cooling | ESM Setpoint--Cooling |
75 | Fan ON Time | Fan ON Time |
76 | Fan OFF Time | Fan OFF Time |
77 | 2nd Stage Heat Enable | 2nd Stage Heat Enable |
78 | Aux Heat Enable | Aux Heat Enable |
79 | 2nd Stage Cool Enable | 2nd Stage Cool Enable |
132 | Run Schedule | Run Schedule |
137 | Backlight Timeout | Backlight Timeout |
141 | Screen Timeout | Screen Timeout |
143 | Sensor (Internal) Offset | Sensor (Internal) Offset |
148 | Screen Contrast | Screen Contrast |
185 | Schedule Enable | Schedule Enable |
228 | Schedule Sun-1 | Schedule Sun-1 |
229 | Schedule Sun-2 | Schedule Sun-2 |
230 | Schedule Sun-3 | Schedule Sun-3 |
231 | Schedule Sun-4 | Schedule Sun-4 |
232 | Schedule Mon-1 | Schedule Mon-1 |
233 | Schedule Mon-2 | Schedule Mon-2 |
234 | Schedule Mon-3 | Schedule Mon-3 |
235 | Schedule Mon-4 | Schedule Mon-4 |
236 | Schedule Tue-1 | Schedule Tue-1 |
237 | Schedule Tue-2 | Schedule Tue-2 |
238 | Schedule Tue-3 | Schedule Tue-3 |
239 | Schedule Tue-4 | Schedule Tue-4 |
240 | Schedule Wed-1 | Schedule Wed-1 |
241 | Schedule Wed-2 | Schedule Wed-2 |
242 | Schedule Wed-3 | Schedule Wed-3 |
243 | Schedule Wed-4 | Schedule Wed-4 |
244 | Schedule Thu-1 | Schedule Thu-1 |
246 | Schedule Thu-3 | Schedule Thu-3 |
247 | Schedule Thu-4 | Schedule Thu-4 |
248 | Schedule Fri-1 | Schedule Fri-1 |
249 | Schedule Fri-2 | Schedule Fri-2 |
250 | Schedule Fri-3 | Schedule Fri-3 |
251 | Schedule Fri-4 | Schedule Fri-4 |
252 | Schedule Sat-1 | Schedule Sat-1 |
253 | Schedule Sat-2 | Schedule Sat-2 |
254 | Schedule Sat-3 | Schedule Sat-3 |
255 | Schedule Sat-4 | Schedule Sat-4 |
Parameter 1: System Type
System Type This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Gas/Electric |
1 | HeatPump |
The manufacturer defined default value is 0
(Gas/Electric).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Fan Type
Fan Type This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Gas |
1 | Electric |
The manufacturer defined default value is 0
(Gas).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Change Over Type
Change Over Type This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | w/Cool |
1 | w/Heat |
The manufacturer defined default value is 0
(w/Cool).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Units
Units
The following option values may be configured -:
Value | Description |
---|---|
0 | Celsius |
1 | Fahrenheit |
The manufacturer defined default value is 1
(Fahrenheit).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 9: Display Lock
Display Lock
The following option values may be configured -:
Value | Description |
---|---|
0 | Unlocked |
1 | Locked |
The manufacturer defined default value is 0
(Unlocked).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Parameter 10: Minimum Off Time
Minimum Off Time Sets the minimum off time before another heating/cooling cycle can begin to provide compressor short cycle protection. The thermostat screen will display WAIT when minimum off time is being enforced.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 5 to 9 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Parameter 11: Minimum Run Time
Minimum Run Time Sets the minimum run time before a heating/cooling cycle can turn off to prevent rapid cycling. Thermostat screen will display "Cool ON" or "Heat ON" while the minimum run time is being enforced.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 9 may be set.
The manufacturer defined default value is 6
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Parameter 12: Heating Delta Stage 1 ON
Heating Delta Stage 1 ON Sets the delta from setpoint that stage 1 heating starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Parameter 13: Heating Delta Stage 1 OFF
Heating Delta Stage 1 OFF Sets the delta from setpoint that stage 1 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 1.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 8 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Parameter 14: Heating Delta Stage 2 ON
Heating Delta Stage 2 ON Sets the delta from setpoint that stage 2 heating starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
Parameter 15: Heating Delta Stage 2 OFF
Heating Delta Stage 2 OFF Sets the delta from setpoint that stage 2 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 2.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 8 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Parameter 16: Heating Delta Stage 3 ON
Heating Delta Stage 3 ON Sets the delta from setpoint that stage 3 heating starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
Parameter 17: Heating Delta Stage 3 OFF
Heating Delta Stage 3 OFF Sets the delta from setpoint that stage 3 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 3This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 8 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
Parameter 18: Cooling Delta Stage 1 ON
Cooling Delta Stage 1 ON Sets the delta from setpoint that stage 1 cooling starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Parameter 19: Cooling Delta Stage 1 OFF
Cooling Delta Stage 1 OFF Sets the delta from setpoint that stage 1 cooling stops. Stage 1 turns off at setpoint minus (-) Delta Stage 1.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 8 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
Parameter 20: Cooling Delta Stage 2 ON
Cooling Delta Stage 2 ON Sets the delta from setpoint that stage 2 cooling starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Parameter 21: Cooling Delta Stage 2 OFF
Cooling Delta Stage 2 OFF Sets the delta from setpoint that stage 2 cooling stops. Stage 1 turns off at setpoint minus (-) Delta Stage 2. Values in the range 0 to 8 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
Parameter 24: H/C Delta
H/C Delta
Sets the minimum separation between the heating and cooling setpoints. Attempts to lower the cooling below the heating setpoint by this amount will PUSH the heating setpoint down to maintain this separation. Same for setting the heating setpoint above the cooling setpoint, it will PUSH the cooling setpoint up to maintain this separation.
Settings in F.
Values in the range 3 to 15 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_24_1
and is of type INTEGER
.
Parameter 25: SetBack Mode
SetBack Mode 0 = No Setback, 1 = Setback, 2 if ESM The following option values may be configured -:
Value | Description |
---|---|
0 | No Setback |
1 | Setback |
2 | ESM |
The manufacturer defined default value is 0
(No Setback).
This parameter has the configuration ID config_25_1
and is of type INTEGER
.
Parameter 29: ESM Setpoint--Heating
ESM Setpoint--Heating
Energy Saving Mode (ESM) Setpoints are the setpoints used when the Energy Saving Mode schedule is selected in the Schedule Mode screen (or via Z-Wave control).
Setting in F.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 65
.
This parameter has the configuration ID config_29_1
and is of type INTEGER
.
Parameter 30: ESM Setpoint--Cooling
ESM Setpoint--Cooling Energy Saving Mode (ESM) Setpoints are the setpoints used when the Energy Saving Mode schedule is selected in the Schedule Mode screen (or via Z-Wave control). Values in the range 0 to 100 may be set.
The manufacturer defined default value is 80
.
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Parameter 75: Fan ON Time
Fan ON Time The fan cycler function cycles the HVAC system fan for an ON period followed by an OFF period continuously. Used to provide minimum air ventilation requirements.
When the Fan ON time is set to a value greater than 0, an additional Cycler Fan mode is present when pressing the FAN button on the thermostat. Values in the range 0 to 120 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_75_1
and is of type INTEGER
.
Parameter 76: Fan OFF Time
Fan OFF Time The fan cycler function cycles the HVAC system fan for an ON period followed by an OFF period continuously. Used to provide minimum air ventilation requirements.
When the Fan ON time is set to a value greater than 0, an additional Cycler Fan mode is present when pressing the FAN button on the thermostat. Values in the range 10 to 120 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_76_1
and is of type INTEGER
.
Parameter 77: 2nd Stage Heat Enable
2nd Stage Heat Enable
The following option values may be configured -:
Value | Description |
---|---|
0 | no 2nd stage heat |
1 | 2nd stage heat |
The manufacturer defined default value is 0
(no 2nd stage heat).
This parameter has the configuration ID config_77_1
and is of type INTEGER
.
Parameter 78: Aux Heat Enable
Aux Heat Enable
The following option values may be configured -:
Value | Description |
---|---|
0 | no aux heat |
1 | aux heat enabled |
The manufacturer defined default value is 0
(no aux heat).
This parameter has the configuration ID config_78_1
and is of type INTEGER
.
Parameter 79: 2nd Stage Cool Enable
2nd Stage Cool Enable
The following option values may be configured -:
Value | Description |
---|---|
0 | no 2nd stage cool |
1 | 2nd stage cool |
The manufacturer defined default value is 0
(no 2nd stage cool).
This parameter has the configuration ID config_79_1
and is of type INTEGER
.
Parameter 132: Run Schedule
Run Schedule Set to 1 if running schedule (RUN is displayed on the thermostat screen). The following option values may be configured -:
Value | Description |
---|---|
0 | not running schedule |
1 | running schedule |
The manufacturer defined default value is 0
(not running schedule).
This parameter has the configuration ID config_132_1
and is of type INTEGER
.
Parameter 137: Backlight Timeout
Backlight Timeout Backlight Timeout is the time (in seconds) from the last button press to the backlight going out.
The time-out can be set between 0 and 120 seconds.
When set to 0, the backlight will remain always on. Values in the range 0 to 120 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_137_1
and is of type INTEGER
.
Parameter 141: Screen Timeout
Screen Timeout This is the time before any screen reverts to the Minimized Screen (temperature display only), after you stop pushing buttons.
Minimized Screen feature is disabled by setting this time to 0 Values in the range 0 to 120 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_141_1
and is of type INTEGER
.
Parameter 143: Sensor (Internal) Offset
Sensor (Internal) Offset The internal temperature sensor can be calibrated to report values different from its actual reading. The offset can range from -7 degrees to +7 degrees.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range -7 to 7 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_143_1
and is of type INTEGER
.
Parameter 148: Screen Contrast
Screen Contrast The Screen Contrast sets the contrast level of the LCD display.
The contrast can be set between 0 and 20. If the display is too light, use a higher number. If dark lines appear on the screen, use a lower number Values in the range 0 to 20 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_148_1
and is of type INTEGER
.
Parameter 185: Schedule Enable
Schedule Enable When enabled (set to 1), the local thermostat's scheduler function is enabled.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_185_1
and is of type INTEGER
.
Parameter 228: Schedule Sun-1
Schedule Sun-1 This value holds information about the first schedule setpoints for Sundays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x06004643 06:00AM 70F / 67F
0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_228_4
and is of type INTEGER
.
Parameter 229: Schedule Sun-2
Schedule Sun-2 This value holds information about the second schedule setpoints for Sundays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x08003e55 08:00AM 62F / 85F
0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_229_4
and is of type INTEGER
.
Parameter 230: Schedule Sun-3
Schedule Sun-3 This value holds information about the third schedule setpoints for Sundays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x1200464e 06:00PM 70F / 78F
0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_230_4
and is of type INTEGER
.
Parameter 231: Schedule Sun-4
Schedule Sun-4 This value holds information about the fourth schedule setpoints for Sundays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_231_4
and is of type INTEGER
.
Parameter 232: Schedule Mon-1
Schedule Mon-1 This value holds information about the first schedule setpoints for Mondays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x06004643 06:00AM 70F / 67F
0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_232_4
and is of type INTEGER
.
Parameter 233: Schedule Mon-2
Schedule Mon-2 This value holds information about the second schedule setpoints for Mondays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x08003e55 08:00AM 62F / 85F
0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_233_4
and is of type INTEGER
.
Parameter 234: Schedule Mon-3
Schedule Mon-3 This value holds information about the third schedule setpoints for Mondays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x1200464e 06:00PM 70F / 78F
0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_234_4
and is of type INTEGER
.
Parameter 235: Schedule Mon-4
Schedule Mon-4 This value holds information about the fourth schedule setpoints for Mondays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_235_4
and is of type INTEGER
.
Parameter 236: Schedule Tue-1
Schedule Tue-1 This value holds information about the first schedule setpoints for Tuesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x06004643 06:00AM 70F / 67F
0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_236_4
and is of type INTEGER
.
Parameter 237: Schedule Tue-2
Schedule Tue-2 This value holds information about the second schedule setpoints for Tuesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x08003e55 08:00AM 62F / 85F
0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_237_4
and is of type INTEGER
.
Parameter 238: Schedule Tue-3
Schedule Tue-3 This value holds information about the third schedule setpoints for Tuesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x1200464e 06:00PM 70F / 78F
0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_238_4
and is of type INTEGER
.
Parameter 239: Schedule Tue-4
Schedule Tue-4 This value holds information about the fourth schedule setpoints for Tuesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_239_4
and is of type INTEGER
.
Parameter 240: Schedule Wed-1
Schedule Wed-1 This value holds information about the first schedule setpoints for Wednesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x06004643 06:00AM 70F / 67F
0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_240_4
and is of type INTEGER
.
Parameter 241: Schedule Wed-2
Schedule Wed-2 This value holds information about the second schedule setpoints for Wednesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x08003e55 08:00AM 62F / 85F
0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_241_4
and is of type INTEGER
.
Parameter 242: Schedule Wed-3
Schedule Wed-3 This value holds information about the third schedule setpoints for Wednesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x1200464e 06:00PM 70F / 78F
0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_242_4
and is of type INTEGER
.
Parameter 243: Schedule Wed-4
Schedule Wed-4 This value holds information about the fourth schedule setpoints for Wednesdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_243_4
and is of type INTEGER
.
Parameter 244: Schedule Thu-1
Schedule Thu-1 This value holds information about the second schedule setpoints for Thursdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x08003e55 08:00AM 62F / 85F
0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_244_4
and is of type INTEGER
.
Parameter 246: Schedule Thu-3
Schedule Thu-3 This value holds information about the third schedule setpoints for Thursdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x1200464e 06:00PM 70F / 78F
0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_246_4
and is of type INTEGER
.
Parameter 247: Schedule Thu-4
Schedule Thu-4 This value holds information about the fourth schedule setpoints for Thursdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_247_4
and is of type INTEGER
.
Parameter 248: Schedule Fri-1
Schedule Fri-1 This value holds information about the first schedule setpoints for Fridays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x06004643 06:00AM 70F / 67F
0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_248_4
and is of type INTEGER
.
Parameter 249: Schedule Fri-2
Schedule Fri-2 This value holds information about the second schedule setpoints for Fridays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x08003e55 08:00AM 62F / 85F
0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_249_4
and is of type INTEGER
.
Parameter 250: Schedule Fri-3
Schedule Fri-3 This value holds information about the fourth schedule setpoints for Fridays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_250_4
and is of type INTEGER
.
Parameter 251: Schedule Fri-4
Schedule Fri-4 This value holds information about the fourth schedule setpoints for Fridays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_251_4
and is of type INTEGER
.
Parameter 252: Schedule Sat-1
Schedule Sat-1 This value holds information about the first schedule setpoints for Saturdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x06004643 06:00AM 70F / 67F
0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_252_4
and is of type INTEGER
.
Parameter 253: Schedule Sat-2
Schedule Sat-2 This value holds information about the second schedule setpoints for Saturdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x08003e55 08:00AM 62F / 85F
0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_253_4
and is of type INTEGER
.
Parameter 254: Schedule Sat-3
Schedule Sat-3 This value holds information about the third schedule setpoints for Saturdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x1200464e 06:00PM 70F / 78F
0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_254_4
and is of type INTEGER
.
Parameter 255: Schedule Sat-4
Schedule Sat-4 This value holds information about the fourth schedule setpoints for Saturdays.
- Byte 1: Hour (0-23)
- Byte 2: Minute (0-59)
- Byte 3: Heat Setpoint (degrees)
- Byte 4: Cool Setpoint (degrees)
Default: 0x16003e52 10:00PM 62F / 82F
0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_255_4
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V2 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_MULTI_CMD_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.