Trane XR524 Touchscreen Comfort Control Thermostat

This describes the Z-Wave device Trane XR524, manufactured by Trane Corporation with the thing type UID of trane_xr524_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

Trane XR524 product image

The Trane XR524 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The Trane 524 Touchscreen Comfort Control is compatible with single and multistage forced air systems, including:

  • Gas furnace systems
  • Oil furnace systems
  • Electric furnace systems
  • Heat pump systems
  • Air conditioning systems

Inclusion Information

  1. Press MENU on the 524 Control.
  2. Press NEXT to advance to the Z-WAVE menu.
  3. Press SELECT

Exclusion Information

  1. Press MENU on the 524 Control.
  2. Press NEXT to scroll to Z-WAVE screen then press SELECT.
  3. Press YES to exclude the control

Channels

The following table summarises the channels available for the Trane XR524 -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Operating State thermostat_state thermostat_state Temperature Number
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (cooling) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Thermostat fan mode thermostat_fanmode thermostat_fanmode
Thermostat fan state thermostat_fanstate thermostat_fanstate

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State

Sets the thermostat operating state.

The thermostat_state channel is of type thermostat_state and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (cooling)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Thermostat fan mode

Channel type information on this channel is not found.

Thermostat fan state

Channel type information on this channel is not found.

Device Configuration

The following table provides a summary of the 59 configuration parameters available in the Trane XR524. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 System Type System Type
2 Fan Type Fan Type
3 Change Over Type Change Over Type
4 Units Units
9 Display Lock Display Lock
10 Minimum Off Time Minimum Off Time
11 Minimum Run Time Minimum Run Time
12 Heating Delta Stage 1 ON Heating Delta Stage 1 ON
13 Heating Delta Stage 1 OFF Heating Delta Stage 1 OFF
14 Heating Delta Stage 2 ON Heating Delta Stage 2 ON
15 Heating Delta Stage 2 OFF Heating Delta Stage 2 OFF
16 Heating Delta Stage 3 ON Heating Delta Stage 3 ON
17 Heating Delta Stage 3 OFF Heating Delta Stage 3 OFF
18 Cooling Delta Stage 1 ON Cooling Delta Stage 1 ON
19 Cooling Delta Stage 1 OFF Cooling Delta Stage 1 OFF
20 Cooling Delta Stage 2 ON Cooling Delta Stage 2 ON
21 Cooling Delta Stage 2 OFF Cooling Delta Stage 2 OFF
24 H/C Delta H/C Delta
25 SetBack Mode SetBack Mode
29 ESM Setpoint--Heating ESM Setpoint--Heating
30 ESM Setpoint--Cooling ESM Setpoint--Cooling
75 Fan ON Time Fan ON Time
76 Fan OFF Time Fan OFF Time
77 2nd Stage Heat Enable 2nd Stage Heat Enable
78 Aux Heat Enable Aux Heat Enable
79 2nd Stage Cool Enable 2nd Stage Cool Enable
132 Run Schedule Run Schedule
137 Backlight Timeout Backlight Timeout
141 Screen Timeout Screen Timeout
143 Sensor (Internal) Offset Sensor (Internal) Offset
148 Screen Contrast Screen Contrast
185 Schedule Enable Schedule Enable
228 Schedule Sun-1 Schedule Sun-1
229 Schedule Sun-2 Schedule Sun-2
230 Schedule Sun-3 Schedule Sun-3
231 Schedule Sun-4 Schedule Sun-4
232 Schedule Mon-1 Schedule Mon-1
233 Schedule Mon-2 Schedule Mon-2
234 Schedule Mon-3 Schedule Mon-3
235 Schedule Mon-4 Schedule Mon-4
236 Schedule Tue-1 Schedule Tue-1
237 Schedule Tue-2 Schedule Tue-2
238 Schedule Tue-3 Schedule Tue-3
239 Schedule Tue-4 Schedule Tue-4
240 Schedule Wed-1 Schedule Wed-1
241 Schedule Wed-2 Schedule Wed-2
242 Schedule Wed-3 Schedule Wed-3
243 Schedule Wed-4 Schedule Wed-4
244 Schedule Thu-1 Schedule Thu-1
246 Schedule Thu-3 Schedule Thu-3
247 Schedule Thu-4 Schedule Thu-4
248 Schedule Fri-1 Schedule Fri-1
249 Schedule Fri-2 Schedule Fri-2
250 Schedule Fri-3 Schedule Fri-3
251 Schedule Fri-4 Schedule Fri-4
252 Schedule Sat-1 Schedule Sat-1
253 Schedule Sat-2 Schedule Sat-2
254 Schedule Sat-3 Schedule Sat-3
255 Schedule Sat-4 Schedule Sat-4

Parameter 1: System Type

System Type This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 Gas/Electric
1 HeatPump

The manufacturer defined default value is 0 (Gas/Electric).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Fan Type

Fan Type This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 Gas
1 Electric

The manufacturer defined default value is 0 (Gas).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Change Over Type

Change Over Type This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 w/Cool
1 w/Heat

The manufacturer defined default value is 0 (w/Cool).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Units

Units

The following option values may be configured -:

Value Description
0 Celsius
1 Fahrenheit

The manufacturer defined default value is 1 (Fahrenheit).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 9: Display Lock

Display Lock

The following option values may be configured -:

Value Description
0 Unlocked
1 Locked

The manufacturer defined default value is 0 (Unlocked).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Minimum Off Time

Minimum Off Time Sets the minimum off time before another heating/cooling cycle can begin to provide compressor short cycle protection. The thermostat screen will display WAIT when minimum off time is being enforced.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 5 to 9 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Minimum Run Time

Minimum Run Time Sets the minimum run time before a heating/cooling cycle can turn off to prevent rapid cycling. Thermostat screen will display "Cool ON" or "Heat ON" while the minimum run time is being enforced.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 9 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Heating Delta Stage 1 ON

Heating Delta Stage 1 ON Sets the delta from setpoint that stage 1 heating starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Heating Delta Stage 1 OFF

Heating Delta Stage 1 OFF Sets the delta from setpoint that stage 1 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 1.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 8 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Heating Delta Stage 2 ON

Heating Delta Stage 2 ON Sets the delta from setpoint that stage 2 heating starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Heating Delta Stage 2 OFF

Heating Delta Stage 2 OFF Sets the delta from setpoint that stage 2 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 2.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 8 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 16: Heating Delta Stage 3 ON

Heating Delta Stage 3 ON Sets the delta from setpoint that stage 3 heating starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 17: Heating Delta Stage 3 OFF

Heating Delta Stage 3 OFF Sets the delta from setpoint that stage 3 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 3This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 8 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_17_1 and is of type INTEGER.

Parameter 18: Cooling Delta Stage 1 ON

Cooling Delta Stage 1 ON Sets the delta from setpoint that stage 1 cooling starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_18_1 and is of type INTEGER.

Parameter 19: Cooling Delta Stage 1 OFF

Cooling Delta Stage 1 OFF Sets the delta from setpoint that stage 1 cooling stops. Stage 1 turns off at setpoint minus (-) Delta Stage 1.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 8 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Parameter 20: Cooling Delta Stage 2 ON

Cooling Delta Stage 2 ON Sets the delta from setpoint that stage 2 cooling starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 21: Cooling Delta Stage 2 OFF

Cooling Delta Stage 2 OFF Sets the delta from setpoint that stage 2 cooling stops. Stage 1 turns off at setpoint minus (-) Delta Stage 2. Values in the range 0 to 8 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Parameter 24: H/C Delta

H/C Delta Sets the minimum separation between the heating and cooling setpoints. Attempts to lower the cooling below the heating setpoint by this amount will PUSH the heating setpoint down to maintain this separation. Same for setting the heating setpoint above the cooling setpoint, it will PUSH the cooling setpoint up to maintain this separation.
Settings in F. Values in the range 3 to 15 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_24_1 and is of type INTEGER.

Parameter 25: SetBack Mode

SetBack Mode 0 = No Setback, 1 = Setback, 2 if ESM The following option values may be configured -:

Value Description
0 No Setback
1 Setback
2 ESM

The manufacturer defined default value is 0 (No Setback).

This parameter has the configuration ID config_25_1 and is of type INTEGER.

Parameter 29: ESM Setpoint--Heating

ESM Setpoint--Heating Energy Saving Mode (ESM) Setpoints are the setpoints used when the Energy Saving Mode schedule is selected in the Schedule Mode screen (or via Z-Wave control).
Setting in F. Values in the range 0 to 100 may be set.

The manufacturer defined default value is 65.

This parameter has the configuration ID config_29_1 and is of type INTEGER.

Parameter 30: ESM Setpoint--Cooling

ESM Setpoint--Cooling Energy Saving Mode (ESM) Setpoints are the setpoints used when the Energy Saving Mode schedule is selected in the Schedule Mode screen (or via Z-Wave control). Values in the range 0 to 100 may be set.

The manufacturer defined default value is 80.

This parameter has the configuration ID config_30_1 and is of type INTEGER.

Parameter 75: Fan ON Time

Fan ON Time The fan cycler function cycles the HVAC system fan for an ON period followed by an OFF period continuously. Used to provide minimum air ventilation requirements.

When the Fan ON time is set to a value greater than 0, an additional Cycler Fan mode is present when pressing the FAN button on the thermostat. Values in the range 0 to 120 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_75_1 and is of type INTEGER.

Parameter 76: Fan OFF Time

Fan OFF Time The fan cycler function cycles the HVAC system fan for an ON period followed by an OFF period continuously. Used to provide minimum air ventilation requirements.

When the Fan ON time is set to a value greater than 0, an additional Cycler Fan mode is present when pressing the FAN button on the thermostat. Values in the range 10 to 120 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_76_1 and is of type INTEGER.

Parameter 77: 2nd Stage Heat Enable

2nd Stage Heat Enable

The following option values may be configured -:

Value Description
0 no 2nd stage heat
1 2nd stage heat

The manufacturer defined default value is 0 (no 2nd stage heat).

This parameter has the configuration ID config_77_1 and is of type INTEGER.

Parameter 78: Aux Heat Enable

Aux Heat Enable

The following option values may be configured -:

Value Description
0 no aux heat
1 aux heat enabled

The manufacturer defined default value is 0 (no aux heat).

This parameter has the configuration ID config_78_1 and is of type INTEGER.

Parameter 79: 2nd Stage Cool Enable

2nd Stage Cool Enable

The following option values may be configured -:

Value Description
0 no 2nd stage cool
1 2nd stage cool

The manufacturer defined default value is 0 (no 2nd stage cool).

This parameter has the configuration ID config_79_1 and is of type INTEGER.

Parameter 132: Run Schedule

Run Schedule Set to 1 if running schedule (RUN is displayed on the thermostat screen). The following option values may be configured -:

Value Description
0 not running schedule
1 running schedule

The manufacturer defined default value is 0 (not running schedule).

This parameter has the configuration ID config_132_1 and is of type INTEGER.

Parameter 137: Backlight Timeout

Backlight Timeout Backlight Timeout is the time (in seconds) from the last button press to the backlight going out. 

The time-out can be set between 0 and 120 seconds. 

When set to 0, the backlight will remain always on. Values in the range 0 to 120 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_137_1 and is of type INTEGER.

Parameter 141: Screen Timeout

Screen Timeout This is the time before any screen reverts to the Minimized Screen (temperature display only), after you stop pushing buttons. 

Minimized Screen feature is disabled by setting this time to 0 Values in the range 0 to 120 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_141_1 and is of type INTEGER.

Parameter 143: Sensor (Internal) Offset

Sensor (Internal) Offset The internal temperature sensor can be calibrated to report values different from its actual reading.  The offset can range from -7 degrees to +7 degrees.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range -7 to 7 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_143_1 and is of type INTEGER.

Parameter 148: Screen Contrast

Screen Contrast The Screen Contrast sets the contrast level of the LCD display.

The contrast can be set between 0 and 20.  If the display is too light, use a higher number.  If dark lines appear on the screen, use a lower number Values in the range 0 to 20 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_148_1 and is of type INTEGER.

Parameter 185: Schedule Enable

Schedule Enable When enabled (set to 1), the local thermostat's scheduler function is enabled.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_185_1 and is of type INTEGER.

Parameter 228: Schedule Sun-1

Schedule Sun-1 This value holds information about the first schedule setpoints for Sundays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  •  Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x06004643 06:00AM 70F / 67F

      0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_228_4 and is of type INTEGER.

Parameter 229: Schedule Sun-2

Schedule Sun-2 This value holds information about the second schedule setpoints for Sundays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x08003e55 08:00AM 62F / 85F

      0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_229_4 and is of type INTEGER.

Parameter 230: Schedule Sun-3

Schedule Sun-3 This value holds information about the third schedule setpoints for Sundays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x1200464e 06:00PM 70F / 78F

      0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_230_4 and is of type INTEGER.

Parameter 231: Schedule Sun-4

Schedule Sun-4 This value holds information about the fourth schedule setpoints for Sundays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x16003e52 10:00PM 62F / 82F

      0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_231_4 and is of type INTEGER.

Parameter 232: Schedule Mon-1

Schedule Mon-1 This value holds information about the first schedule setpoints for Mondays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x06004643 06:00AM 70F / 67F

      0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_232_4 and is of type INTEGER.

Parameter 233: Schedule Mon-2

Schedule Mon-2 This value holds information about the second schedule setpoints for Mondays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x08003e55 08:00AM 62F / 85F

      0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_233_4 and is of type INTEGER.

Parameter 234: Schedule Mon-3

Schedule Mon-3 This value holds information about the third schedule setpoints for Mondays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x1200464e 06:00PM 70F / 78F

      0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_234_4 and is of type INTEGER.

Parameter 235: Schedule Mon-4

Schedule Mon-4 This value holds information about the fourth schedule setpoints for Mondays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x16003e52 10:00PM 62F / 82F

      0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_235_4 and is of type INTEGER.

Parameter 236: Schedule Tue-1

Schedule Tue-1 This value holds information about the first schedule  setpoints for Tuesdays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x06004643 06:00AM 70F / 67F

      0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_236_4 and is of type INTEGER.

Parameter 237: Schedule Tue-2

Schedule Tue-2 This value holds information about the second schedule setpoints for Tuesdays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

 Default:  0x08003e55 08:00AM 62F / 85F

      0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_237_4 and is of type INTEGER.

Parameter 238: Schedule Tue-3

Schedule Tue-3 This value holds information about the third schedule setpoints for Tuesdays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x1200464e 06:00PM 70F / 78F

      0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_238_4 and is of type INTEGER.

Parameter 239: Schedule Tue-4

Schedule Tue-4 This value holds information about the fourth schedule setpoints for Tuesdays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x16003e52 10:00PM 62F / 82F

      0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_239_4 and is of type INTEGER.

Parameter 240: Schedule Wed-1

Schedule Wed-1 This value holds information about the first schedule setpoints for Wednesdays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x06004643 06:00AM 70F / 67F

      0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_240_4 and is of type INTEGER.

Parameter 241: Schedule Wed-2

Schedule Wed-2 This value holds information about the second schedule setpoints for Wednesdays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x08003e55 08:00AM 62F / 85F

      0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_241_4 and is of type INTEGER.

Parameter 242: Schedule Wed-3

Schedule Wed-3 This value holds information about the third schedule setpoints for Wednesdays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x1200464e 06:00PM 70F / 78F

      0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_242_4 and is of type INTEGER.

Parameter 243: Schedule Wed-4

Schedule Wed-4 This value holds information about the fourth schedule setpoints for Wednesdays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x16003e52 10:00PM 62F / 82F

      0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_243_4 and is of type INTEGER.

Parameter 244: Schedule Thu-1

Schedule Thu-1 This value holds information about the second schedule setpoints for Thursdays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x08003e55 08:00AM 62F / 85F

      0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_244_4 and is of type INTEGER.

Parameter 246: Schedule Thu-3

Schedule Thu-3 This value holds information about the third schedule setpoints for Thursdays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x1200464e 06:00PM 70F / 78F

      0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_246_4 and is of type INTEGER.

Parameter 247: Schedule Thu-4

Schedule Thu-4 This value holds information about the fourth schedule setpoints for Thursdays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x16003e52 10:00PM 62F / 82F

      0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_247_4 and is of type INTEGER.

Parameter 248: Schedule Fri-1

Schedule Fri-1 This value holds information about the first schedule setpoints for Fridays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x06004643 06:00AM 70F / 67F

      0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_248_4 and is of type INTEGER.

Parameter 249: Schedule Fri-2

Schedule Fri-2 This value holds information about the second schedule setpoints for Fridays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x08003e55 08:00AM 62F / 85F

      0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_249_4 and is of type INTEGER.

Parameter 250: Schedule Fri-3

Schedule Fri-3 This value holds information about the fourth schedule setpoints for Fridays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x16003e52 10:00PM 62F / 82F

      0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_250_4 and is of type INTEGER.

Parameter 251: Schedule Fri-4

Schedule Fri-4 This value holds information about the fourth schedule setpoints for Fridays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x16003e52 10:00PM 62F / 82F

      0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_251_4 and is of type INTEGER.

Parameter 252: Schedule Sat-1

Schedule Sat-1 This value holds information about the first schedule setpoints for Saturdays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x06004643 06:00AM 70F / 67F

      0x06001519 06:00AM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_252_4 and is of type INTEGER.

Parameter 253: Schedule Sat-2

Schedule Sat-2 This value holds information about the second schedule setpoints for Saturdays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x08003e55 08:00AM 62F / 85F

      0x0800101d 08:00AM 16C / 29CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_253_4 and is of type INTEGER.

Parameter 254: Schedule Sat-3

Schedule Sat-3 This value holds information about the third schedule setpoints for Saturdays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x1200464e 06:00PM 70F / 78F

      0x12001519 06:00PM 21C / 25CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_254_4 and is of type INTEGER.

Parameter 255: Schedule Sat-4

Schedule Sat-4 This value holds information about the fourth schedule setpoints for Saturdays.

  • Byte 1: Hour   (0-23)
  • Byte 2: Minute (0-59)
  • Byte 3: Heat Setpoint (degrees)
  • Byte 4: Cool Setpoint (degrees)

Default:  0x16003e52 10:00PM 62F / 82F

      0x1600101b 10:00PM 16C / 27CThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_255_4 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V2
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CMD_V1

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.