009303 Wall Controller
This describes the Z-Wave device 009303, manufactured by Popp & Co with the thing type UID of popp_009303_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The 009303 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
Overview
The Wall Controller is a 4 button Z-Wave device capable to act both as primary or secondary controller. The four buttons can control other Z-Wave devices such as switches, dimmer and even door locks directly. Various options – configurable by Z-Wave configuration commands – define the actions and the commands used for this control. It is possible to use two sets of buttons (one for on/open/up and one for off/closed/down) or four single buttons to control four different groups of devices.
The controller also allows triggering scenes in a central controller. Again different modes can be configured to adapt to the various implementations of scenes in different central controllers in the market. Control options also include special modes like „all on/off“ or always controlling the Z-Wave device in proximity to the controller.
Inclusion Information
see attached file "Popp 009303 Battery Wall Controller Manual" (section Reference Documents)
Exclusion Information
see attached file "Popp 009303 Battery Wall Controller Manual" (section Reference Documents)
Wakeup Information
The 009303 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
see attached file "Popp 009303 Battery Wall Controller Manual" (section Reference Documents)
Channels
The following table summarises the channels available for the 009303 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number | |
Battery Level | battery-level | system.battery_level | Battery | Number |
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Device Configuration
The following table provides a summary of the 10 configuration parameters available in the 009303. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Button 1 and 3 pair mode | Button 1 and 3 pair mode. |
2 | Button 2 and 4 pair mode | Button 2 and 4 pair mode. |
11 | Command to control Group A | Command to control Group A |
12 | Command to control Group B | Command to control Group B |
13 | Command to control Group C | Command to control Group C |
14 | Command to control Group D | Command to control Group D |
21 | Send the following switch all commands | |
22 | Invert buttons | |
25 | Block wake up even when Wake Up Interval is set | |
30 | End unsolicited battery report on Wake Up. | |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Parameter 1: Button 1 and 3 pair mode
Button 1 and 3 pair mode. In separate mode button 1 works with Group A, button 3 with Group C. Click is ON, Hold is dimming UP, Double click is OFF, Click-Hold is dimming DOWN. In pair button 1/3 are UP/DOWN correspondingly. Click is ON/OFF, Hold is dimming UP/DOWN. Single clicks works with Group A, double click with Group C. The following option values may be configured -:
Value | Description |
---|---|
0 | Separately |
1 | In pair without double clicks (Default) |
2 | In pair with double clicks |
The manufacturer defined default value is 1
(In pair without double clicks (Default)).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Button 2 and 4 pair mode
Button 2 and 4 pair mode. In separate mode button 2 works with control group B, button 4 with control group D. Click is ON, Hold is dimming UP, Double click is OFF, Click-Hold is dimming DOWN. In pair button B/D are UP/DOWN correspondingly. Click is ON/OFF, Hold is dimming UP/DOWN. Single clicks works with Group B, double click with Group D. The following option values may be configured -:
Value | Description |
---|---|
0 | Separately |
1 | In pair without double clicks (Default) |
2 | In pair with double clicks |
The manufacturer defined default value is 1
(In pair without double clicks (Default)).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 11: Command to control Group A
Command to control Group A Defines the command to be sent to devices of control group A when the related button is pressed. The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Switch on/off and Dim |
2 | Switch on/off only (send Basic Set) |
3 | Switch all |
4 | Send scenes |
5 | Send preconfigured scenes |
6 | Control devices in proximity |
7 | Control door lock |
8 | Central scene to gateway (default) |
The manufacturer defined default value is 8
(Central scene to gateway (default)).
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Parameter 12: Command to control Group B
Command to control Group B Defines the command to be sent to devices of control group B when the related button is pressed. The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Switch on/off and Dim |
2 | Switch on/off only (send Basic Set) |
3 | Switch all |
4 | Send scenes |
5 | Send preconfigured scenes |
6 | Control devices in proximity |
7 | Control door lock |
8 | Central scene to gateway (default) |
The manufacturer defined default value is 8
(Central scene to gateway (default)).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Parameter 13: Command to control Group C
Command to control Group C Defines the command to be sent to devices of control group C when the related button is pressed. The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Switch on/off and Dim |
2 | Switch on/off only (send Basic Set) |
3 | Switch all |
4 | Send scenes |
5 | Send preconfigured scenes |
6 | Control devices in proximity |
7 | Control door lock |
8 | Central scene to gateway (default) |
The manufacturer defined default value is 8
(Central scene to gateway (default)).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Parameter 14: Command to control Group D
Command to control Group D Defines the command to be sent to devices of control group D when the related button is pressed. The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Switch on/off and Dim |
2 | Switch on/off only (send Basic Set) |
3 | Switch all |
4 | Send scenes |
5 | Send preconfigured scenes |
6 | Control devices in proximity |
7 | Control door lock |
8 | Central scene to gateway (default) |
The manufacturer defined default value is 8
(Central scene to gateway (default)).
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
Parameter 21: Send the following switch all commands
The following option values may be configured -:
Value | Description |
---|---|
1 | Switch off only (default) |
2 | Switch on only |
255 | Switch all on and off |
The manufacturer defined default value is 1
(Switch off only (default)).
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
Parameter 22: Invert buttons
The following option values may be configured -:
Value | Description |
---|---|
0 | No (default) |
1 | Yes |
The manufacturer defined default value is 0
(No (default)).
This parameter has the configuration ID config_22_1
and is of type INTEGER
.
Parameter 25: Block wake up even when Wake Up Interval is set
The following option values may be configured -:
Value | Description |
---|---|
0 | Wake up is blocked (default) |
1 | Wake up is possible |
The manufacturer defined default value is 0
(Wake up is blocked (default)).
This parameter has the configuration ID config_25_1
and is of type INTEGER
.
Parameter 30: End unsolicited battery report on Wake Up.
The following option values may be configured -:
Value | Description |
---|---|
0 | No |
1 | To same node as Wake Up Notification |
2 | Broadcast to neighbors |
The manufacturer defined default value is 0
(No).
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Wakeup Interval
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 009303 supports 5 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 10 nodes.
Group 2: Control Group A
Association group 2 supports 10 nodes.
Group 3: Control Group B
Association group 3 supports 10 nodes.
Group 4: Control Group C
Association group 4 supports 10 nodes.
Group 5: Control Group D
Association group 5 supports 10 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_CONTROLLER_CONF_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1 | |
COMMAND_CLASS_MULTI_CMD_V1 |