7.7 KiB
layout | title |
---|---|
documentation | MH-S311H - ZWave |
{% include base.html %}
MH-S311H Touch Panel Switch (Single) High inrush current
This describes the Z-Wave device MH-S311H, manufactured by McoHome Technology Co., Ltd with the thing type UID of mcohome_mhs311_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The MH-S311H supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Touch Panel Switch is a wall switch with built-in Z-Wave module. It supports basic command class,multi channel command class and multi channel association command class, which can control all associated devices synchronously. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers.
Inclusion Information
Press and hold any key on the panel for 8 seconds. If inclusion is successful, all INDICATION LEDs on the panel will turn green, and all switches will turn on.
Exclusion Information
Press and hold any key on the panel for 8 seconds. If the exclusion is successful, all INDICATION LEDs on the panel will turn orange, and all switches will turn off. The exclusion will delete all association data.
Channels
The following table summarises the channels available for the MH-S311H -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Scene Number | scene_number | scene_number | Number | |
Switch 1 | switch_binary1 | switch_binary | Switch | Switch |
Switch
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
Switch 1
Switch the power on and off.
The switch_binary1
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Device Configuration
The following table provides a summary of the 5 configuration parameters available in the MH-S311H. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
2 | Switch state saved or not when power failure | 0=Saved 1=not saved |
3 | ALL ON/ALL OFF | 0,1,2,255 |
4 | LED Backlit brightness level | 0x00 LED disabled 0x01~0x0A Min level-Max level >0x0A same level as 0x0A |
5 | Key Mode | 0-4 |
6 | Key On duration | 0=infinite 1~65535=unit "sec" |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 2: Switch state saved or not when power failure
0=Saved 1=not saved 0= not saved,switch will be off when powered again
1= saved,switch will keep the same state when powered again Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: ALL ON/ALL OFF
0,1,2,255 0=forbid ALL ON, forbid ALL OFF
1=forbid ALL ON, allow ALL OFF
2=allow ALL ON, forbid ALL OFF
255=allow ALL ON, allow ALL OFF Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: LED Backlit brightness level
0x00 LED disabled 0x01~0x0A Min level-Max level >0x0A same level as 0x0A
Values in the range 0 to 10 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: Key Mode
0-4 0=single click to switch on/off status
1=Key default as off state. When it is turned on, then it will be turned off automatically after a time period , which can be set in item 5
2=Key default as on state. When it is turned off, then it will be turned on automatically after a time period , which can be set in item 5
3=hold >3s then key is on, and off once released
4=single click to switch on/off status + hold >3s then key is on, and off once released Values in the range 0 to 4 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 6: Key On duration
0=infinite 1~65535=unit "sec"
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_6_2
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The MH-S311H supports 2 association groups.
Group 1: All Status Reports
Association group 1 supports 1 node.
Group 2: Switch Button Group 1
Association group 2 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V2 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Endpoint 1
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 |
Documentation Links