8.9 KiB
layout | title |
---|---|
documentation | GE 28167 (ZW3104) - ZWave |
{% include base.html %}
GE 28167 (ZW3104) Plug-In Smart Dimmer
This describes the Z-Wave device GE 28167 (ZW3104), manufactured by Jasco Products with the thing type UID of ge_28167_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The GE 28167 (ZW3104) does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
Overview
Transform any home into a smart home with the GE Z-Wave Plug-In Smart Dimmer. The Smart Dimmer enables wireless control of on/off and dim functions for standard incandescent table and floor lamps, as well as dimmable fluorescent, LED and CFL fixtures and more! Use the dimmer control to customize the lighting output and create the perfect ambiance for any room. The space-saving horizontal module plugs into a standard wall receptacle without blocking the second outlet or obstructing placement of furniture. The Dimmer provides one Z-Wave enabled outlet for the lamp you would like to control. Take control of your home lighting with GE Z-Wave Smart Lighting Controls!
Inclusion Information
Once the controller is ready to add your smart dimmer, single press and release the manual/program button on the smart dimmer to add it in the network.
Exclusion Information
Once the controller is ready to remove your device, press and release the manual/program button on the smart dimmer to remove it from the network
Wakeup Information
The GE 28167 (ZW3104) does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Channels
The following table summarises the channels available for the GE 28167 (ZW3104) -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number |
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Device Configuration
The following table provides a summary of the 7 configuration parameters available in the GE 28167 (ZW3104). Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | LED Light | LED Light |
7 | Dim Steps (From Z-Wave Controller) | Dim Rate Adjustments (From Z-Wave Controller) |
8 | Dim Timing (From Z-Wave Controller) | Dim Rate Adjustments (From Z-Wave Controller) |
9 | Dim Steps (When Manually Controlled) | Dim Rate Adjustments (When Manually Controlled) |
10 | Dim Timing (When Manually Controlled) | Dim Rate Adjustments (When Manually Controlled) |
11 | Dim Steps (All-On/Off Commands) | Dim Rate Adjustments (All-On/Off Commands) |
12 | Dim Rate Adjustments (All-On/Off Command) | Dim Rate Adjustments (All-On/Off Command) |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 3: LED Light
LED Light
The following option values may be configured -:
Value | Description |
---|---|
0 | LED On when light is turned Off |
1 | LED On when light is turned On |
2 | LED always Off |
The manufacturer defined default value is 0
(LED On when light is turned Off).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 7: Dim Steps (From Z-Wave Controller)
Dim Rate Adjustments (From Z-Wave Controller) Number of steps or levels Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Parameter 8: Dim Timing (From Z-Wave Controller)
Dim Rate Adjustments (From Z-Wave Controller) Timing of steps Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_8_2
and is of type INTEGER
.
Parameter 9: Dim Steps (When Manually Controlled)
Dim Rate Adjustments (When Manually Controlled) Number of steps or levels Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Parameter 10: Dim Timing (When Manually Controlled)
Dim Rate Adjustments (When Manually Controlled) Timing of steps Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_10_2
and is of type INTEGER
.
Parameter 11: Dim Steps (All-On/Off Commands)
Dim Rate Adjustments (All-On/Off Commands) Dim Rate Adjustments (When Receiving All-On/Off Commands)
Number of steps or levels Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Parameter 12: Dim Rate Adjustments (All-On/Off Command)
Dim Rate Adjustments (All-On/Off Command) Dim Rate Adjustments (When Receiving All-On/Off Command)
Timing of steps Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_12_2
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The GE 28167 (ZW3104) supports 3 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
Group 2: Association Group 2
supports Basic Set and is controlled with the local load
Association group 2 supports 5 nodes.
Group 3: Association Group 3
supports Basic Set and is controlled by double pressing the button
Association group 3 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.