openhab-docs/_addons_bindings/zwave/doc/ge/28167_0_0.md

8.9 KiB

layout title
documentation GE 28167 (ZW3104) - ZWave

{% include base.html %}

GE 28167 (ZW3104) Plug-In Smart Dimmer

This describes the Z-Wave device GE 28167 (ZW3104), manufactured by Jasco Products with the thing type UID of ge_28167_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

GE 28167 (ZW3104) product image

The GE 28167 (ZW3104) does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

Transform any home into a smart home with the GE Z-Wave Plug-In Smart Dimmer. The Smart Dimmer enables wireless control of on/off and dim functions for standard incandescent table and floor lamps, as well as dimmable fluorescent, LED and CFL fixtures and more! Use the dimmer control to customize the lighting output and create the perfect ambiance for any room. The space-saving horizontal module plugs into a standard wall receptacle without blocking the second outlet or obstructing placement of furniture. The Dimmer provides one Z-Wave enabled outlet for the lamp you would like to control. Take control of your home lighting with GE Z-Wave Smart Lighting Controls!

Inclusion Information

Once the controller is ready to add your smart dimmer, single press and release the manual/program button on the smart dimmer to add it in the network.

Exclusion Information

Once the controller is ready to remove your device, press and release the manual/program button on the smart dimmer to remove it from the network

Wakeup Information

The GE 28167 (ZW3104) does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Channels

The following table summarises the channels available for the GE 28167 (ZW3104) -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the GE 28167 (ZW3104). Detailed information on each parameter can be found in the sections below.

Param Name Description
3 LED Light LED Light
7 Dim Steps (From Z-Wave Controller) Dim Rate Adjustments (From Z-Wave Controller)
8 Dim Timing (From Z-Wave Controller) Dim Rate Adjustments (From Z-Wave Controller)
9 Dim Steps (When Manually Controlled) Dim Rate Adjustments (When Manually Controlled)
10 Dim Timing (When Manually Controlled) Dim Rate Adjustments (When Manually Controlled)
11 Dim Steps (All-On/Off Commands) Dim Rate Adjustments (All-On/Off Commands)
12 Dim Rate Adjustments (All-On/Off Command) Dim Rate Adjustments (All-On/Off Command)
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: LED Light

LED Light

The following option values may be configured -:

Value Description
0 LED On when light is turned Off
1 LED On when light is turned On
2 LED always Off

The manufacturer defined default value is 0 (LED On when light is turned Off).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 7: Dim Steps (From Z-Wave Controller)

Dim Rate Adjustments (From Z-Wave Controller) Number of steps or levels Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Dim Timing (From Z-Wave Controller)

Dim Rate Adjustments (From Z-Wave Controller) Timing of steps Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: Dim Steps (When Manually Controlled)

Dim Rate Adjustments (When Manually Controlled) Number of steps or levels Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Dim Timing (When Manually Controlled)

Dim Rate Adjustments (When Manually Controlled) Timing of steps Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: Dim Steps (All-On/Off Commands)

Dim Rate Adjustments (All-On/Off Commands) Dim Rate Adjustments (When Receiving All-On/Off Commands)

Number of steps or levels Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Dim Rate Adjustments (All-On/Off Command)

Dim Rate Adjustments (All-On/Off Command) Dim Rate Adjustments (When Receiving All-On/Off Command)

Timing of steps Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The GE 28167 (ZW3104) supports 3 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Group 2: Association Group 2

supports Basic Set and is controlled with the local load

Association group 2 supports 5 nodes.

Group 3: Association Group 3

supports Basic Set and is controlled by double pressing the button

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_SWITCH_MULTILEVEL_V2
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.