7.6 KiB
layout | title |
---|---|
documentation | DSC14 - ZWave |
{% include base.html %}
DSC14 Micro Motor Controller
This describes the Z-Wave device DSC14, manufactured by AEON Labs with the thing type UID of aeon_dsc14_00_000
.
The device is in the category of Blinds, defining Roller shutters, window blinds, etc..
The DSC14 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
The Aeon Labs Micro Motor Controller is a Motor Control Class C Specific Device which is connected with window rail to remote control curtain to any position that you want directly.
Inclusion Information
Click the Zwave button once.
Exclusion Information
Click the Zwave button once.
Channels
The following table summarises the channels available for the DSC14 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Blinds Control | blinds_control | blinds_control | Blinds | Rollershutter |
Switch
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Blinds Control
Provides start / stop control of blinds.
The blinds_control
channel is of type blinds_control
and supports the Rollershutter
item and is in the Blinds
category.
Device Configuration
The following table provides a summary of the 12 configuration parameters available in the DSC14. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Type of Sensor Report | |
2 | Blinking Behavior | |
80 | Notification on Status Change | |
90 | Disable automated reporting | Disables automated sending of a Report triggered by minimum value. |
91 | Minimum Change to send Report (Watt) | |
92 | Minimum Change to send Report (%) | |
101 | reports to send automatically | Bitmask of Group 1 reports |
102 | Which reports to send automatically to group 2 | Bitmask of Group 2 reports |
103 | Bitmask of Group 3 reports | Which reports to send automatically to group 3 |
111 | Interval to send out reports of group 1 | |
112 | Interval to send out reports of group 2 | |
113 | Interval to send out reports of group 3 |
Parameter 1: Type of Sensor Report
The following option values may be configured -:
Value | Description |
---|---|
0 | Power |
1 | Voltage |
The manufacturer defined default value is 0
(Power).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Blinking Behavior
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Parameter 80: Notification on Status Change
The following option values may be configured -:
Value | Description |
---|---|
0 | Nothing |
1 | Hail |
2 | Basic CC Report |
The manufacturer defined default value is 0
(Nothing).
This parameter has the configuration ID config_80_1
and is of type INTEGER
.
Parameter 90: Disable automated reporting
Disables automated sending of a Report triggered by minimum value. Disables Function of automated sending of a Report triggered by minimal change of value. The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_90_1
and is of type INTEGER
.
Parameter 91: Minimum Change to send Report (Watt)
Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_91_2
and is of type INTEGER
.
Parameter 92: Minimum Change to send Report (%)
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_92_1
and is of type INTEGER
.
Parameter 101: reports to send automatically
Bitmask of Group 1 reports The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values:
- Wattage=4
- Current=2
- Voltage=1 Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_101_4
and is of type INTEGER
.
Parameter 102: Which reports to send automatically to group 2
Bitmask of Group 2 reports The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values:
- Wattage=4
- Current=2
- Voltage=1 Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_102_4
and is of type INTEGER
.
Parameter 103: Bitmask of Group 3 reports
Which reports to send automatically to group 3 The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values:
- Wattage=4
- Current=2
- Voltage=1 Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_103_4
and is of type INTEGER
.
Parameter 111: Interval to send out reports of group 1
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Parameter 112: Interval to send out reports of group 2
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Parameter 113: Interval to send out reports of group 3
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DSC14 supports 1 association group.
Group 1: Group 1
Status Reports
Association group 1 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | Linked to BASIC |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Documentation Links