This describes the Z-Wave device ZME_05433, manufactured by Z-Wave.Me with the thing type UID of zwaveme_zme05433_00_000
.
The ZME_05433 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
No device information is provided in the database. Consider updating the database to improve the documentation.
Channels
The following table summarises the channels available for the ZME_05433 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | Number |
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel supports the Number
item.
Device Configuration
The following table provides a summary of the 7 configuration parameters available in the ZME_05433. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | LED mode | Set LED indication mode |
2 | Automatically switch off after | If not zero, automatically switch off after a user defined time |
3 | What to do on RF off command | Defines how to interpret RF Off command. |
4 | Ignore start level | ignore start level in StartLevelChange |
5 | Dimming speed | Time to dim on button presses |
6 | Dimming long speed | Time to dim on button holds and StartLevelChange |
7 | Set maximum light level on On click | set action on ON command |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 1: LED mode
Set LED indication mode Set LED indication mode The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Show switch state |
2 | Night mode (inverted switch state) |
3 | Operated by Indicator Command Class (Default) |
The manufacturer defined default value is 3
(Operated by Indicator Command Class (Default)).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Automatically switch off after
If not zero, automatically switch off after a user defined time Automatically switch off after: 0 Disabled (Default); 1 — 65535 sec The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled (Default) |
1 | Sec |
The manufacturer defined default value is 0
(Disabled (Default)).
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Parameter 3: What to do on RF off command
Defines how to interpret RF Off command. Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button operations are not disabled). The following option values may be configured -:
Value | Description |
---|---|
0 | Switch off (Default) |
1 | Ignore |
2 | Switch on |
3 | Switch on if load is off else switch off |
The manufacturer defined default value is 0
(Switch off (Default)).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Ignore start level
ignore start level in StartLevelChange Defines if the dimmer shall ignore start level in StartLevelChange command despite it is specified or not The following option values may be configured -:
Value | Description |
---|---|
0 | No |
1 | Yes (Default) |
The manufacturer defined default value is 1
(Yes (Default)).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: Dimming speed
Time to dim on button presses Time to dim on button presses and Set command (if it has no duration specified). If not 0, dimming will be done smoothly to preserv bulb life. The following option values may be configured, in addition to values in the range 0 to 255 -:
Value | Description |
---|---|
0 | Instantly |
30 | Default |
The manufacturer defined default value is 30
(Default).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 6: Dimming long speed
Time to dim on button holds and StartLevelChange Time to dim on button holds and StartLevelChange command (if it has no duration specified). Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Parameter 7: Set maximum light level on On click
set action on ON command Defines if the dimmer shall set maximum light level on On command. By default on On command dimmer restores last level. This parameter allows to configure to set maximum level on second On command (if already On) or to always switch on to maximum level The following option values may be configured -:
Value | Description |
---|---|
0 | No (Default) |
1 | If already On |
2 | Always |
The manufacturer defined default value is 0
(No (Default)).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZME_05433 supports 3 association groups.
Group 1: Association group 1
Single press and hold of up/down buttons (max. nodes in group: 14) Association group 1: Single press and hold of up/down buttons (max. nodes in group: 14)
Association group 1 supports 14 nodes.
Group 2: Association group 2
Double press and press-hold of up/down buttons (max. nodes in group: 14)
Association group 2 supports 14 nodes.
Group 3: Association group 3
Send Reports on blind state change Send Reports on blind state change (max. nodes in group: 14)
Association group 3 supports 14 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_SCENE_CONTROLLER_CONF_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_NODE_NAMING_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.