7.7 KiB
layout | title |
---|---|
documentation | YRD110 - ZWave |
{% include base.html %}
YRD110 Yale button deadbolt without keyway
This describes the Z-Wave device YRD110, manufactured by ASSA ABLOY with the thing type UID of yale_yrd110_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The YRD110 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Overview
No device information is provided in the database. Consider updating the database to improve the documentation.
Channels
The following table summarises the channels available for the YRD110 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Door Lock | lock_door | Door | Switch |
Alarm (access) | alarm_access | Door | Switch |
Alarm (power) | alarm_power | Door | Switch |
Alarm (raw) | alarm_raw | String | |
Clock Time Offset | time_offset | Temperature | Number |
Door Lock
Lock and unlock the door.
The lock_door
channel supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Alarm (access)
Indicates if the access control alarm is triggered.
The alarm_access
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Alarm (power)
Indicates if a power alarm is triggered.
The alarm_power
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Alarm (raw)
Provides alarm parameters as json string.
The alarm_raw
channel supports the String
item. This is a read only channel so will only be updated following state changes from the device.
This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.
Clock Time Offset
Provides the current time difference for the devices time.
The time_offset
channel supports the Number
item and is in the Temperature
category.
Device Configuration
The following table provides a summary of the 6 configuration parameters available in the YRD110. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Volume | Volume of beeps |
2 | Auto relock | Auto relocking after unlocked |
3 | Auto relock time | Time for auto relock |
4 | Wrong code limit | Number of incorrect PINs before lockout |
7 | Shutdown time | Incorrect attempts shutdown time |
8 | Operation Mode | Operation Mode |
Lock Timeout | Sets the time after which the door will auto lock |
Parameter 1: Volume
Volume of beeps
The following option values may be configured -:
Value | Description |
---|---|
1 | Loud |
3 | Silent |
The manufacturer defined default value is 1
(Loud).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Auto relock
Auto relocking after unlocked
The following option values may be configured -:
Value | Description |
---|---|
0 | No auto-relock |
255 | Auto relock |
The manufacturer defined default value is 0
(No auto-relock).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Auto relock time
Time for auto relock Amount of seconds between the door is unlocked and when it automatically attempts to re-lock itself, when auto-relocking is enabled. Values in the range 5 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Wrong code limit
Number of incorrect PINs before lockout Number of incorrect PINs that can be keyed in before lock goes into temporary keypad lockout mode. Values in the range 1 to 7 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 7: Shutdown time
Incorrect attempts shutdown time Amount of time lock should ignore the keypad, if the number of incorrect PINs is exceeded. (Can still be locked and unlocked by zwave while in shutdown.)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 255 may be set.
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
This is a read only parameter.
Parameter 8: Operation Mode
Operation Mode This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Normal |
1 | vacation |
2 | privacy |
The manufacturer defined default value is 0
(Normal).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Lock Timeout
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The YRD110 supports 1 association group.
Group 1: Receive Alarms
Group that will receive alarm notices from the lock The lock supports 1 association group with 5 devices. Alarm Reports are sent out unsolicited to devices included in the association group.
Association group 1 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1 | |
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1 | |
COMMAND_CLASS_DOOR_LOCK_V1 | |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_PROTECTION_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_TIME_V1 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 |
Documentation Links