WPS104 Energy Driven Switch
This describes the Z-Wave device WPS104, manufactured by wiDom with the thing type UID of widom_wps104_00_000
.
The WPS104 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
No device information is provided in the database. Consider updating the database to improve the documentation.
Channels
The following table summarises the channels available for the WPS104 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Sensor (power) | sensor_power | Energy | Number |
Electric meter (volts) | meter_voltage | Energy | Number |
Electric meter (power factor) | meter_powerfactor | Energy | Number |
Electric meter (amps) | meter_current | Energy | Number |
Electric meter (watts) | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | Energy | Number |
Switch
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Sensor (power)
Indicates the energy consumption (kWh).
The sensor_power
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (volts)
Indicates the instantaneous voltage.
The meter_voltage
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (power factor)
Indicates the instantaneous power factor.
The meter_powerfactor
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (amps)
Indicates the instantaneous current consumption.
The meter_current
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (watts)
Indicates the instantaneous power consumption.
The meter_watts
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (kWh)
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Device Configuration
The following table provides a summary of the 32 configuration parameters available in the WPS104. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Controlling the relay by means of a single click on the external switch or on the integrated button. TOGGLE: If initial status is ON, then final status is OFF. If initial status is OFF, then final status is ON. ON: If the initial status | |
20 | Device Status | The final status achieved by the device when it receives a Basic Set command through the Z-Wave network. Available Parameters are; AS RECIEVED: If received command is ON, then final status is ON. If received command is OFF, then final status |
30 | Overcurrent Level | Sets the current level above which the time spent above that level is measured. Defined value is divided by 100. |
31 | Overcurrent Time | Sets the time beyond which, in the case of overcurrent at a level higher than that established in parameter 30, an OverCurrent event occurs. |
32 | Next State | Defines the next state of the device if an overcurrent event has occurred. Available Parameters: IGNORE - The device maintains the initial status. ON - If the initial status is OFF the system switches to ON; conversely, it maintains its statu |
33 | Meter Reset | Provides total operating time from last meter reset. When set to 0 it resets the cumulative values of energy and total operating time. |
34 | Energy flow | Determines whether energy events are related to energy consumed or energy produced. Available Parameters are: CONSUMED - Events will be active for Consumed energy flows to which the positive sign will be attributed. PRODUCED - Events will be |
35 | UP Power Level | Sets the level of instantaneous power in Watts beyond which time of permanence above this level is calculated. 0 W - 11250 W Define level of instantaneous power. |
36 | UP Power Time | Sets the time in seconds beyond which, if instantaneous power remains at levels exceeding threshold defined by parameter 35, a UP Power event occurs. 0 sec - 10800 sec Define time parameter. |
37 | UP Power State | Defines the next status of the device in the case of a UP Power event occurring. Available Parameters: IGNORE - The device maintains the initial status. ON - If the initial status is OFF the system switches to ON; conversely, it maintains its |
38 | UP Power Associated | Sets the level of instantaneous power beyond which the time of permanence below this level is calculated. 0 - Associated devices are switched OFF. -1 - Associated devices are switched ON. 1 - 99 Set parameter for dimming purposes. |
39 | DOWN Power Level | Sets the level of instantaneous power beyond which the time of permanence below this level is calculated. 0 W - 11250 W Define level of instantaneous power. |
40 | DOWN Power Time | SSets the time beyond which, if instantaneous power remains at levels below threshold defined by parameter 39, a DOWN Power event occurs. 0 sec - 10800 sec. Define time parameter. |
41 | DOWN Power State | Defines the next state of the device in the case of a DOWN Power event occurring. Available Parameters: IGNORE - The device maintains the initial status. ON - If the initial status is OFF the system switches to ON; conversely, it maintains it |
42 | DOWN Power Associated | Defines the status of associated devices in the presence of a DOWN Power event. 0 - Associated devices are switched OFF. -1 - Associated devices are switched ON. 1 - 99 Set parameter for dimming purposes. |
43 | DOWN Power Associated | Sets the energy level that once exceeded an Energy Limit event occurs. Available Range: 0 KWh - 2000000 KWh |
44 | Energy Limit State | Defines the next state of the device in the case of an Energy Limit event occurring. Available Parameters: IGNORE - The device maintains the initial status. ON - If the initial status is OFF the system switches to ON; conversely, it maintains |
45 | Variation Instantaneous Power | Defines the percentage variation of instantaneous power determining the sending of the report. Available Range: 1 % - 100 % |
46 | Report Time Frequency | Defines the percentage variation of instantaneous power determining the sending of the report. Available Range: 1 min - 100 mins |
47 | Variation Total Energy | Defines the increase of total energy required to generate a report listing the level of total energy to the devices associated to the Energy Notification Group. |
48 | Nominal Voltage | Defines the nominal voltage value in tenths of volts. Together with parameter No. 49 this is used by the automatic notification system to send reports on variations of voltage. Available Range: 1100 v - 2500 v |
49 | Fall In Maximum Voltage | Defines, as a percentage, the nominal value for permitted fall in maximum voltage. Available Range: 1 - 100% |
50 | Electric parameters subjected to automatic notification | Defines which electric parameters, other than power, will be subjected to automatic notification. The value to be set for this parameter must be calculated as the sum of values associated to the individual electric parameter: Power=0, Energy=2, |
51 | Voltage RMS value | Reading of this parameter returns the value of voltage RMS at the time of the reading expressed in tenths of Volts. |
52 | Current RMS value | Returns the value of current RMS expressed in hundredths of Amperes. |
53 | Power Factor | Returns the value of power factor as a percentage |
54 | Total energy consumed | Returns the value of total energy consumed expressed in Wh (thousandths of KWh). |
55 | Total energy produced | Returns the value of total energy consumed expressed in Wh (thousandths of KWh). |
60 | Start-up status | Defines the status of the device following a restart. |
61 | Configuration reset | Defines which parameters should be reset to default values. |
62 | Type of external switch | Defines the type of external switch connected to the device. |
63 | Load Control | Defines the load control mode. Available Parameters are: 1 - DIRECT CONTROL The external load is controlled directly by the relay. Reference diagram local load control. 2 - The external load is controlled by a contactor that in a resting sta |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 1:
Controlling the relay by means of a single click on the external switch or on the integrated button. TOGGLE: If initial status is ON, then final status is OFF. If initial status is OFF, then final status is ON. ON: If the initial status
The following option values may be configured -:
Value | Description |
---|---|
1 | TOGGLE:ON/OFF |
2 | On |
3 | Off |
4 | IGNORE |
The manufacturer defined default value is 1
(TOGGLE:ON/OFF).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 20: Device Status
The final status achieved by the device when it receives a Basic Set command through the Z-Wave network. Available Parameters are; AS RECIEVED: If received command is ON, then final status is ON. If received command is OFF, then final status
The following option values may be configured -:
Value | Description |
---|---|
1 | AS RECEIVED |
2 | IGNORE IF ON |
3 | IGNORE IF OFF |
4 | IGNORE |
The manufacturer defined default value is 1
(AS RECEIVED).
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Parameter 30: Overcurrent Level
Sets the current level above which the time spent above that level is measured. Defined value is divided by 100.
Values in the range 0 to 4500 may be set.
The manufacturer defined default value is 4500
.
This parameter has the configuration ID config_30_2
and is of type INTEGER
.
Parameter 31: Overcurrent Time
Sets the time beyond which, in the case of overcurrent at a level higher than that established in parameter 30, an OverCurrent event occurs.
Values in the range 0 to 10800 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_31_2
and is of type INTEGER
.
Parameter 32: Next State
Defines the next state of the device if an overcurrent event has occurred. Available Parameters: IGNORE - The device maintains the initial status. ON - If the initial status is OFF the system switches to ON; conversely, it maintains its statu
The following option values may be configured -:
Value | Description |
---|---|
0 | IGNORE |
1 | On |
2 | Off |
3 | TOGGLE |
The manufacturer defined default value is 0
(IGNORE).
This parameter has the configuration ID config_32_1
and is of type INTEGER
.
Parameter 33: Meter Reset
Provides total operating time from last meter reset. When set to 0 it resets the cumulative values of energy and total operating time.
The following option values may be configured -:
Value | Description |
---|---|
0 | Meter parameters, including total operating time, will be reset. |
1 | Greater than 0 – IGNORE (The meter will not be reset.) |
The manufacturer defined default value is 0
(Meter parameters, including total operating time, will be reset.).
This parameter has the configuration ID config_33_4
and is of type INTEGER
.
Parameter 34: Energy flow
Determines whether energy events are related to energy consumed or energy produced. Available Parameters are: CONSUMED - Events will be active for Consumed energy flows to which the positive sign will be attributed. PRODUCED - Events will be
The following option values may be configured -:
Value | Description |
---|---|
1 | CONSUMED |
2 | PRODUCED |
The manufacturer defined default value is 1
(CONSUMED).
This parameter has the configuration ID config_34_1
and is of type INTEGER
.
Parameter 35: UP Power Level
Sets the level of instantaneous power in Watts beyond which time of permanence above this level is calculated. 0 W - 11250 W Define level of instantaneous power.
Values in the range 0 to 11250 may be set.
The manufacturer defined default value is 11250
.
This parameter has the configuration ID config_35_2
and is of type INTEGER
.
Parameter 36: UP Power Time
Sets the time in seconds beyond which, if instantaneous power remains at levels exceeding threshold defined by parameter 35, a UP Power event occurs. 0 sec - 10800 sec Define time parameter.
Values in the range 0 to 10800 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_36_2
and is of type INTEGER
.
Parameter 37: UP Power State
Defines the next status of the device in the case of a UP Power event occurring. Available Parameters: IGNORE - The device maintains the initial status. ON - If the initial status is OFF the system switches to ON; conversely, it maintains its
The following option values may be configured -:
Value | Description |
---|---|
0 | IGNORE |
1 | On |
2 | Off |
3 | TOGGLE |
The manufacturer defined default value is 0
(IGNORE).
This parameter has the configuration ID config_37_1
and is of type INTEGER
.
Parameter 38: UP Power Associated
Sets the level of instantaneous power beyond which the time of permanence below this level is calculated. 0 - Associated devices are switched OFF. -1 - Associated devices are switched ON. 1 - 99 Set parameter for dimming purposes.
Values in the range -1 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_38_1
and is of type INTEGER
.
Parameter 39: DOWN Power Level
Sets the level of instantaneous power beyond which the time of permanence below this level is calculated. 0 W - 11250 W Define level of instantaneous power.
Values in the range 0 to 11250 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_39_2
and is of type INTEGER
.
Parameter 40: DOWN Power Time
SSets the time beyond which, if instantaneous power remains at levels below threshold defined by parameter 39, a DOWN Power event occurs. 0 sec - 10800 sec. Define time parameter.
Values in the range 0 to 10800 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_40_2
and is of type INTEGER
.
Parameter 41: DOWN Power State
Defines the next state of the device in the case of a DOWN Power event occurring. Available Parameters: IGNORE - The device maintains the initial status. ON - If the initial status is OFF the system switches to ON; conversely, it maintains it
The following option values may be configured -:
Value | Description |
---|---|
0 | IGNORE |
1 | On |
2 | Off |
3 | TOGGLE |
The manufacturer defined default value is 0
(IGNORE).
This parameter has the configuration ID config_41_1
and is of type INTEGER
.
Parameter 42: DOWN Power Associated
Defines the status of associated devices in the presence of a DOWN Power event. 0 - Associated devices are switched OFF. -1 - Associated devices are switched ON. 1 - 99 Set parameter for dimming purposes.
Values in the range -1 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_42_1
and is of type INTEGER
.
Parameter 43: DOWN Power Associated
Sets the energy level that once exceeded an Energy Limit event occurs. Available Range: 0 KWh - 2000000 KWh
Values in the range 0 to 2000000 may be set.
The manufacturer defined default value is 2000000
.
This parameter has the configuration ID config_43_4
and is of type INTEGER
.
Parameter 44: Energy Limit State
Defines the next state of the device in the case of an Energy Limit event occurring. Available Parameters: IGNORE - The device maintains the initial status. ON - If the initial status is OFF the system switches to ON; conversely, it maintains
The following option values may be configured -:
Value | Description |
---|---|
0 | IGNORE |
1 | On |
2 | Off |
3 | TOGGLE |
The manufacturer defined default value is 0
(IGNORE).
This parameter has the configuration ID config_44_1
and is of type INTEGER
.
Parameter 45: Variation Instantaneous Power
Defines the percentage variation of instantaneous power determining the sending of the report. Available Range: 1 % - 100 %
Values in the range 1 to 100 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_45_1
and is of type INTEGER
.
Parameter 46: Report Time Frequency
Defines the percentage variation of instantaneous power determining the sending of the report. Available Range: 1 min - 100 mins
Values in the range 1 to 100 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_46_1
and is of type INTEGER
.
Parameter 47: Variation Total Energy
Defines the increase of total energy required to generate a report listing the level of total energy to the devices associated to the Energy Notification Group.
The following option values may be configured -:
Value | Description |
---|---|
0 | IGNORE: No report provided. |
1 | No report provided. |
2 | Report at 1 hundredth of KWh. |
3 | Report at 1 tenth of KWh |
4 | Report at 1 KWh |
The manufacturer defined default value is 3
(Report at 1 tenth of KWh).
This parameter has the configuration ID config_47_1
and is of type INTEGER
.
Parameter 48: Nominal Voltage
Defines the nominal voltage value in tenths of volts. Together with parameter No. 49 this is used by the automatic notification system to send reports on variations of voltage. Available Range: 1100 v - 2500 v
Values in the range 1100 to 2500 may be set.
The manufacturer defined default value is 2300
.
This parameter has the configuration ID config_48_2
and is of type INTEGER
.
Parameter 49: Fall In Maximum Voltage
Defines, as a percentage, the nominal value for permitted fall in maximum voltage. Available Range: 1 - 100%
Values in the range 1 to 100 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_49_1
and is of type INTEGER
.
Parameter 50: Electric parameters subjected to automatic notification
Defines which electric parameters, other than power, will be subjected to automatic notification. The value to be set for this parameter must be calculated as the sum of values associated to the individual electric parameter: Power=0, Energy=2,
Values in the range 0 to 62 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_50_2
and is of type INTEGER
.
Parameter 51: Voltage RMS value
Reading of this parameter returns the value of voltage RMS at the time of the reading expressed in tenths of Volts.
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_51_2
and is of type INTEGER
.
Parameter 52: Current RMS value
Returns the value of current RMS expressed in hundredths of Amperes.
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_52_2
and is of type INTEGER
.
Parameter 53: Power Factor
Returns the value of power factor as a percentage
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_53_4
and is of type INTEGER
.
Parameter 54: Total energy consumed
Returns the value of total energy consumed expressed in Wh (thousandths of KWh).
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_54_4
and is of type INTEGER
.
Parameter 55: Total energy produced
Returns the value of total energy consumed expressed in Wh (thousandths of KWh).
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_55_4
and is of type INTEGER
.
Parameter 60: Start-up status
Defines the status of the device following a restart.
The following option values may be configured -:
Value | Description |
---|---|
1 | ON: Device on |
2 | OFF: Device off |
3 | PREVIOUS STATUS: Status prior to restart |
The manufacturer defined default value is 3
(PREVIOUS STATUS: Status prior to restart).
This parameter has the configuration ID config_60_1
and is of type INTEGER
.
Parameter 61: Configuration reset
Defines which parameters should be reset to default values.
The following option values may be configured -:
Value | Description |
---|---|
0 | FACTORY RESET: The device is reset to the original factory settings. |
1 | ASSOCIATIONS RESET: All associations and only the associations are res |
2 | CONFIGURATIONS RESET: The associations are maintained while all other |
3 | IGNORE: No action is performed. |
The manufacturer defined default value is 3
(IGNORE: No action is performed.).
This parameter has the configuration ID config_61_1
and is of type INTEGER
.
Parameter 62: Type of external switch
Defines the type of external switch connected to the device.
The following option values may be configured -:
Value | Description |
---|---|
0 | IGNORE: The external switch is not connected or not present. |
1 | BUTTON: The external switch is a normally open button. |
2 | SWITCH: The external switch is a traditional switch. |
3 | AUTOMATIC RECOGNITION: |
The manufacturer defined default value is 3
(AUTOMATIC RECOGNITION:).
This parameter has the configuration ID config_62_1
and is of type INTEGER
.
Parameter 63: Load Control
Defines the load control mode. Available Parameters are: 1 - DIRECT CONTROL The external load is controlled directly by the relay. Reference diagram local load control. 2 - The external load is controlled by a contactor that in a resting sta
The following option values may be configured -:
Value | Description |
---|---|
1 | DIRECT CONTROL |
2 | CONTROL BY MEANS OF A CONTACTOR WITH NORMALLY OPEN COMMAND: |
3 | CONTROL BY MEANS OF A CONTACTOR WITH NORMALLY CLOSED COMMAND: |
4 | AS AN EXTERNAL INDICATOR: |
The manufacturer defined default value is 1
(DIRECT CONTROL).
This parameter has the configuration ID config_63_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The WPS104 supports 3 association groups.
Group 1: Lifeline Group
Devices who will receive notification on: status changes; energy level and power; local reset of the device
Received commands: Basic Report, Device Reset Locally Notification, Meter Report, Multilevel Sensor: Power Report
Association group 1 supports 8 nodes.
Group 2: Up Power Level Group
Devices controlled from Up Power Event
Association group 2 supports 8 nodes.
Group 3: Down Power Level Group
Devices controlled from Down Power Event
Association group 3 supports 8 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V3 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |