5.8 KiB
layout | title |
---|---|
documentation | TZEMT400BB32MAA - ZWave |
{% include base.html %}
TZEMT400BB32MAA Trane Z-Wave Programmable Thermostat
This describes the Z-Wave device TZEMT400BB32MAA, manufactured by Trane Corporation with the thing type UID of trane_tzemt400bb32maa_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The TZEMT400BB32MAA supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Thermostat for Heating and Cooling HVAC System control
Inclusion Information
- Press the MENU button on the thermostat.
- Scroll down to Z Wave Install, and press the Select button.
- Press the Yes button to enroll the thermostat.
Exclusion Information
- Press the MENU button on the thermostat.
- Scroll down to Z Wave Install, and press the Select button.
- Press the Yes button to enroll the thermostat.
Channels
The following table summarises the channels available for the TZEMT400BB32MAA -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | Temperature | Number:Temperature |
Setpoint (cooling) | thermostat_setpoint | Temperature | Number:Temperature |
Thermostat fan mode | thermostat_fanmode | ||
Thermostat fan state | thermostat_fanstate | ||
Schedule Mode | config_decimal | Number | |
Clock Time Offset | time_offset | Temperature | Number |
Sensor (temperature)
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Thermostat mode
Sets the thermostat.
The thermostat_mode
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Operating State
Sets the thermostat operating state.
The thermostat_state
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Setpoint (heating)
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Setpoint (cooling)
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Thermostat fan mode
Channel type information on this channel is not found.
Thermostat fan state
Channel type information on this channel is not found.
Schedule Mode
Send 0 to Hold and 1 to Run Schedule.
Generic class for configuration parameter.
The config_decimal
channel supports the Number
item.
Clock Time Offset
Provides the current time difference for the devices time.
The time_offset
channel supports the Number
item and is in the Temperature
category.
Device Configuration
The following table provides a summary of the 1 configuration parameters available in the TZEMT400BB32MAA. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
132 | Schedule Mode |
Parameter 132: Schedule Mode
The following option values may be configured -:
Value | Description |
---|---|
0 | Hold |
1 | Schedule |
The manufacturer defined default value is 0
(Hold).
This parameter has the configuration ID config_132_1
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The TZEMT400BB32MAA supports 1 association group.
Group 1: Reports
Association group 1 supports 1 node.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_LOCK_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Documentation Links