3.6 KiB
layout | title |
---|---|
documentation | FE599NX - ZWave |
{% include base.html %}
FE599NX Connected Keypad with Lever
This describes the Z-Wave device FE599NX, manufactured by Allegion with the thing type UID of schlage_fe599nx_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The FE599NX supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Overview
No device information is provided in the database. Consider updating the database to improve the documentation.
Channels
The following table summarises the channels available for the FE599NX -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Door Lock | lock_door | Door | Switch |
Alarm | alarm_general | Door | Switch |
Battery Level | battery-level | Battery | Number |
Door Lock
Lock and unlock the door.
The lock_door
channel supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Alarm
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
Device Configuration
The device has no configuration parameters defined.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The FE599NX supports 1 association group.
Group 1: Alarm Reports
Association group 1 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_DOOR_LOCK_V1 | |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_LOCK_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Documentation Links