7.3 KiB
layout | title |
---|---|
documentation | BE369 - ZWave |
{% include base.html %}
BE369 Keypad Deadbolt
This describes the Z-Wave device BE369, manufactured by Allegion with the thing type UID of schlage_be369_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The BE369 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Overview
Schlage BE369 Keypad Door Lock -
Shares same hardware as FE599 lock (lever version).
Inclusion Information
When prompted, follow the lock’s enrollment process:
- Enter your 6-digit programming code
- Wait for the device to beep three times
- Press the Schlage button
- Press 0
- The Schlage button will blink three times to confirm
Exclusion Information
When prompted, follow the lock’s removal process:
- Enter your 6-digit programming code
- Wait for the device to beep three times
- Press the Schlage button
- Press 0
- The Schlage button will blink three times to confirm
Channels
The following table summarises the channels available for the BE369 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Door Lock | lock_door | Door | Switch |
Alarm | alarm_general | Door | Switch |
Alarm (access) | notification_access_control | Number | |
Alarm (number) | alarm_number | Number | |
Alarm (raw) | alarm_raw | String | |
Battery Level | battery-level | Battery | Number |
Door Lock
Lock and unlock the door.
The lock_door
channel supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Alarm
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Alarm (access)
Access Control.
The notification_access_control
channel supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Previous Events cleared |
1 | Manual Lock Operation |
2 | Manual Unlock Operation |
3 | RF Lock Operation |
4 | RF Unlock Operation |
5 | Keypad Lock Operation |
6 | Keypad Unlock Operation |
7 | Manual Not Fully Locked Operation |
8 | RF Not Fully Locked Operation |
9 | Auto Lock Locked Operation |
10 | Auto Lock Not Fully Operation |
11 | LockJammed |
12 | All user codes deleted |
13 | Single user code deleted |
14 | New user code added |
15 | New user code not added due to duplicate code |
16 | Keypad temporary disabled |
17 | Keypad busy |
18 | New Program code Entered- Unique code for lock configuration |
19 | Manually Enter user Access code exceeds code limit |
20 | Unlock by RF with invalid user code |
21 | Locked by RF with invalid user code |
22 | Window/Door is open |
23 | Window/Door is closed |
64 | Barrier performing initialization process |
65 | Barrier operation (Open / Close) force has been exceeded |
66 | Barrier motor has exceeded manufacturer's operational time limit |
67 | Barrier operation has exceeded physical mechanical limits |
68 | Barrier unable to perform requested operation due to UL requirements |
69 | Barrier Unattended operation has been disabled per UL requirements |
70 | Barrier failed to perform Requested operation, device malfunction |
71 | Barrier Vacation Mode |
72 | Barrier Safety Beam Obstacle |
73 | Barrier Sensor Not Detected / Supervisory Error |
74 | Barrier Sensor Low Battery Warning |
75 | Barrier detected short in WallStation wires |
76 | Barrier associated with non-Z-wave remote control |
Alarm (number)
Provides the raw alarm value.
The alarm_number
channel supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
Alarm (raw)
Provides alarm parameters as json string.
The alarm_raw
channel supports the String
item. This is a read only channel so will only be updated following state changes from the device.
This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
Device Configuration
The following table provides a summary of the 1 configuration parameters available in the BE369. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | Beeper | Turn key beep on or off for keypad |
Lock Timeout | Sets the time after which the door will auto lock |
Parameter 3: Beeper
Turn key beep on or off for keypad Turn key beep on or off for keypad The following option values may be configured -:
Value | Description |
---|---|
0 | Disable Beeper |
1 | Enable Beeper |
The manufacturer defined default value is 1
(Enable Beeper).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Lock Timeout
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The BE369 supports 1 association group.
Group 1: Alarm Reports
Association group 1 supports 2 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_DOOR_LOCK_V1 | |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.