ZTS-500 Thermostat
This describes the Z-Wave device ZTS-500, manufactured by Remotec with the thing type UID of remotec_zts500_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The ZTS-500 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Overview
Remotec ZTS-500 is a security Z-Wave enabled thermostat designed to control residential HVAC systems.
Inclusion Information
Z-Wave Inclusion and Exclusion
When ZTS-500 is not in any Z-Wave network, "Z-Wave Disconnected" icon will show up on the standby menu, you can navigate to the Z-Wave from operation menu to do the inclusion. Or you can go to system settings menu, the first menu is for Z-Wave setup, you can do both inclusion and exclusion.
Tap the "+" scroll key when an inclusion or exclusion request is sent by a local Z-Wave gateway, HUB, or controller. If the procedure is successful, a "" screen will display. If the procedure fails, a "" screen will display.
If the ZTS-500 is included in a Z-Wave network, the "Z-Wave Disconnected" icon will no longer display in the standby menu.
Note: All Z-Wave configuration parameter values will keep no changes after excluding the unit from the network, except for the association groups information. The ZTS-500 will retain the last selected HVAC system type.
Exclusion Information
Z-Wave Inclusion and Exclusion
When ZTS-500 is not in any Z-Wave network, "Z-Wave Disconnected" icon will show up on the standby menu, you can navigate to the Z-Wave from operation menu to do the inclusion. Or you can go to system settings menu, the first menu is for Z-Wave setup, you can do both inclusion and exclusion.
Tap the "+" scroll key when an inclusion or exclusion request is sent by a local Z-Wave gateway, HUB, or controller. If the procedure is successful, a "" screen will display. If the procedure fails, a "" screen will display.
If the ZTS-500 is included in a Z-Wave network, the "Z-Wave Disconnected" icon will no longer display in the standby menu.
Note: All Z-Wave configuration parameter values will keep no changes after excluding the unit from the network, except for the association groups information. The ZTS-500 will retain the last selected HVAC system type.
Channels
The following table summarises the channels available for the ZTS-500 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | Temperature | Number |
Setpoint (cooling) | thermostat_setpoint | Temperature | Number:Temperature |
Setpoint (heating) | thermostat_setpoint | Temperature | Number:Temperature |
Thermostat fan mode | thermostat_fanmode | ||
Thermostat fan state | thermostat_fanstate | ||
Battery Level | battery-level | Battery | Number |
Sensor (temperature)
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Thermostat mode
Sets the thermostat.
The thermostat_mode
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Operating State
Sets the thermostat operating state.
The thermostat_state
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Setpoint (cooling)
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Setpoint (heating)
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Thermostat fan mode
Channel type information on this channel is not found.
Thermostat fan state
Channel type information on this channel is not found.
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
Device Configuration
The device has no configuration parameters defined.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZTS-500 supports 3 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 1 node.
Group 2: Group 1
Association group 2 supports 2 nodes.
Group 3: Group 2
Association group 3 supports 2 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.