ZMNHSD DIN Rail Dimmer
This describes the Z-Wave device ZMNHSD, manufactured by Goap with the thing type UID of qubino_zmnhsd_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZMNHSD supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
This Z-wave module is used for dimming the bulb or to manage the speed of a fan. The module can be controlled either thorough Z-wave network or through the wall switch.
The module is designed to be mounted inside an electrical cabinet onto DIN rail.
Module measures power consumption of bulb or fan and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network.
Inclusion Information
Press service button S for more than 6 seconds or press push button I five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply
Exclusion Information
If service button S is pressed more than 2 and less than 6 seconds (or if push button I is pressed three times within 3s) module is excluded, but configuration parametres are not set to default values.
Note: If the module is included with parameter 5 with value different from default and module reset is done, wait at least 30s before next inclusion
Channels
The following table summarises the channels available for the ZMNHSD -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Dimmer | switch_dimmer | DimmableLight | Dimmer |
Electric meter (kWh) | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | Energy | Number |
Switch
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
Electric meter (kWh)
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (watts)
Indicates the instantaneous power consumption.
The meter_watts
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Device Configuration
The following table provides a summary of the 17 configuration parameters available in the ZMNHSD. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Input switch type | |
5 | Working mode | With this parameter it is possible to change the module presentation on the user interface. |
10 | Activate / deactivate functions ALL ON / ALL OFF | DIN dimmer module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. |
11 | Automatic turning off output after set time | |
12 | Automatic turning on output after set time | |
21 | Enable / Disable Double click function | If Double click function is enabled, a fast double click on the push button will set dimming power at maximum dimming value. |
30 | Saving the state of the device after a power failure | If state saving is enabled, DIN dimmer module saves its state before power failure (it returns to the last position saved before a power failure). If state saving is disabled, DIN dimmer module does not save the state after a powe |
40 | Power reporting in watts on power change | Set value means percentage, set value from 0 - 100 = 0% - 100%. Default value is 5. 0 – Reporting Disabled 1 – 100 = 1% - 100% Reporting enabled. Power report is sent (push) only when actual power in Watts in real time changes for more than set p |
42 | Power reporting in Watts by time interval | Set value means time interval (0 – 32767) in seconds, when power report is sent. |
60 | Minimum dimming value | |
61 | Maximum dimming value | |
65 | Dimming time (soft on/off) | Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through UI (BasicSet). |
-
default value 100 = 1s
-
1 - 255 = 100 mseconds – 25500 mseconds (25.5 | | 66 | Dimming time when key pressed | Time to moving the Dimmer between min. and max values (in seconds). | | 67 | Ignore start level | This parameter is used with association group 3. A receiving device SHOULD respect the start level if the Ignore Start Level bit is 0. A receiving device MUST ignore the start level if the Ignore Start Level bit is 1. | | 68 | Dimming duration | This parameter is used with association group 3. | | 110 | Temperature sensor offset settings | Set value is added or subtracted to actual measured value by sensor. Available configuration parameters:
-
default value 32536
-
32536 – offset is 0.0C
-
From 1 to 100 – value from 0.1 °C to 10.0 °C is added to | | 120 | Digital temperature sensor reporting | If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters:
-
default value 5 = 0.5°C
-
0 – Reporting disabled | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 1: Input switch type
The following option values may be configured -:
Value | Description |
---|---|
0 | 0 - Mono-stable switch type (push button) |
1 | 1 - Bi-stable switch type |
The manufacturer defined default value is 0
(0 - Mono-stable switch type (push button)).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 5: Working mode
With this parameter it is possible to change the module presentation on the user interface.
The following option values may be configured -:
Value | Description |
---|---|
0 | Dimmer |
1 | Switch |
The manufacturer defined default value is 0
(Dimmer).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 10: Activate / deactivate functions ALL ON / ALL OFF
DIN dimmer module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.
The following option values may be configured -:
Value | Description |
---|---|
0 | ALL ON is not active, ALL OFF is not active |
1 | ALL ON is not active, ALL OFF active |
2 | ALL ON active, ALL OFF is not active |
255 | ALL ON active, ALL OFF active |
The manufacturer defined default value is 255
(ALL ON active, ALL OFF active).
This parameter has the configuration ID config_10_2
and is of type INTEGER
.
Parameter 11: Automatic turning off output after set time
- 0 - Auto OFF disabled
- 1 – 32536 = 1 second – 32536 seconds Auto OFF enabled with defined time, step is 1 second. The following option values may be configured, in addition to values in the range 0 to 32536 -:
Value | Description |
---|---|
0 | Auto off DISABLED |
The manufacturer defined default value is 0
(Auto off DISABLED).
This parameter has the configuration ID config_11_2
and is of type INTEGER
.
Parameter 12: Automatic turning on output after set time
- 0 - Auto ON disabled
- 1 – 32536 = 1 second – 32536 seconds Auto ON enabled with defined time, step is 1 second. The following option values may be configured, in addition to values in the range 0 to 32536 -:
Value | Description |
---|---|
0 | Auto on DISABLED |
The manufacturer defined default value is 0
(Auto on DISABLED).
This parameter has the configuration ID config_12_2
and is of type INTEGER
.
Parameter 21: Enable / Disable Double click function
If Double click function is enabled, a fast double click on the push button will set dimming power at maximum dimming value.
The following option values may be configured -:
Value | Description |
---|---|
0 | 0 - double click disabled |
1 | 1 - double click enabled |
The manufacturer defined default value is 0
(0 - double click disabled).
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
Parameter 30: Saving the state of the device after a power failure
If state saving is enabled, DIN dimmer module saves its state before power failure (it returns to the last position saved before a power failure). If state saving is disabled, DIN dimmer module does not save the state after a powe
The following option values may be configured -:
Value | Description |
---|---|
0 | 0 - Save state enabled |
1 | 1 - Save state disabled |
The manufacturer defined default value is 0
(0 - Save state enabled).
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Parameter 40: Power reporting in watts on power change
Set value means percentage, set value from 0 - 100 = 0% - 100%. Default value is 5. 0 – Reporting Disabled 1 – 100 = 1% - 100% Reporting enabled. Power report is sent (push) only when actual power in Watts in real time changes for more than set p
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
Parameter 42: Power reporting in Watts by time interval
Set value means time interval (0 – 32767) in seconds, when power report is sent.
- 0 – reporting disabled
- 1 – 32767 = 1 second – 32767 seconds. Reporting enabled. Power report is sent with time interval set by entered Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 300
.
This parameter has the configuration ID config_42_2
and is of type INTEGER
.
Parameter 60: Minimum dimming value
- 1-98 = 1% – 98%, step is 1%. Minimum dimming value is set by entered value.
NOTE: The minimum level may not be higher than the maximum level! 1% min. dimming value is defined by Z- Wave multilevel device class. Values in the range 1 to 98 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_60_1
and is of type INTEGER
.
Parameter 61: Maximum dimming value
- 2-99 = 2% – 99%, step is 1%. Maximum dimming value is set by entered value.
NOTE: The maximum level may not be lower than the minimum level! 99% max. dimming value is defined by Z- Wave multilevel device class. Values in the range 2 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_61_1
and is of type INTEGER
.
Parameter 65: Dimming time (soft on/off)
Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through UI (BasicSet).
- default value 100 = 1s
- 1 - 255 = 100 mseconds – 25500 mseconds (25.5
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 100
.
This parameter has the configuration ID config_65_2
and is of type INTEGER
.
Parameter 66: Dimming time when key pressed
Time to moving the Dimmer between min. and max values (in seconds).
- default value 3 = 3s
- 1- 255 = 1 second – 255 seconds. Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_66_2
and is of type INTEGER
.
Parameter 67: Ignore start level
This parameter is used with association group 3. A receiving device SHOULD respect the start level if the Ignore Start Level bit is 0. A receiving device MUST ignore the start level if the Ignore Start Level bit is 1.
The following option values may be configured -:
Value | Description |
---|---|
0 | 0 - respect start level |
1 | 1 - ignore start level |
The manufacturer defined default value is 0
(0 - respect start level).
This parameter has the configuration ID config_67_1
and is of type INTEGER
.
Parameter 68: Dimming duration
This parameter is used with association group 3. The Duration field MUST specify the time that the transition should take from the current value to the new target value. A supporting device SHOULD respect the specified Duration value. Values in the range 0 to 127 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_68_1
and is of type INTEGER
.
Parameter 110: Temperature sensor offset settings
Set value is added or subtracted to actual measured value by sensor. Available configuration parameters:
- default value 32536
- 32536 – offset is 0.0C
- From 1 to 100 – value from 0.1 °C to 10.0 °C is added to
Values in the range 1 to 32536 may be set.
The manufacturer defined default value is 32536
.
This parameter has the configuration ID config_110_2
and is of type INTEGER
.
Parameter 120: Digital temperature sensor reporting
If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters:
- default value 5 = 0.5°C
- 0 – Reporting disabled
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_120_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZMNHSD supports 5 association groups.
Group 1: Controller Updates
Association group 1 supports 1 node.
Group 2: I1 basic on/off
Association group 2 supports 16 nodes.
Group 3: I1 start/stop level change
Association group 3 supports 16 nodes.
Group 4: Multilevel set
Association group 4 supports 16 nodes.
Group 5: Multilevel sensor report
Association group 5 supports 16 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.