PAN06 In Wall Dual Relay (1 Way) Switch Module 2 x 1.5kW

This describes the Z-Wave device PAN06, manufactured by Philio Technology Corp with the thing type UID of philio_pan06_00_000. This version of the device is limited to firmware versions below 1.7

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

PAN06 product image

The PAN06 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The PAN06 allows controlling two independent loads both wirelessly via Z-Wave and locally utilizing a traditional wall switch. Thanks to its calibration technology the device cannot only be used to switch resistive devices but also works perfectly with many kind of reactive or resistive loads such as fluorescent lights or LEDs.
The device is placed in a wall box right behind the normal switch. The switch is not longer directly
connected to the load but acts as input device for the insert that is controlling the load. This device is
designed for a 3 wire system and needs a neutral wire in the wall box.

Inclusion Information

  1. Have Z-Wave Controller entered inclusion mode
  2. Pressing Include button of PAN06 three times within 1.5 seconds will enter inclusion mode.

Exclusion Information

  1. Have Z-Wave Controller entered exclusion mode
  2. Pressing Include button of PAN06 three times within 1.5 seconds will enter exclusion mode.

Channels

The following table summarises the channels available for the PAN06 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Alarm alarm_general Door Switch
Switch 1 switch_binary1 Switch Switch
Switch 2 switch_binary2 Switch Switch
Switch 3 switch_binary3 Switch Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Switch 2

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Switch 3

Switch the power on and off.

The switch_binary3 channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the PAN06. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Selected endpoint Send Basic Command Class
2 Switch mode Change the external switch mode
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Selected endpoint

Send Basic Command Class If Controller not using Multi_Channel command class to access the endpoint of PAN06, you may configure the endpoint value to react the Basic Command Class The following option values may be configured -:

Value Description
1 Relay 1 + 2
2 Relay 1
3 Relay 2

The manufacturer defined default value is 1 (Relay 1 + 2).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Switch mode

Change the external switch mode

The following option values may be configured -:

Value Description
1 Edge mode
2 Pulse mode
3 Edge-Toggle mode

The manufacturer defined default value is 1 (Edge mode).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PAN06 supports 3 association groups.

Group 1: Relay 1 + 2

Association group 1 supports 1 node.

Group 2: Relay 1

Association group 2 supports 1 node.

Group 3: Relay 2

Association group 3 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.