26 KiB
layout | title |
---|---|
documentation | LHC5020 - ZWave |
{% include base.html %}
LHC5020 DIN-rail module with 10 digital ouputs and 4 digital inputs
This describes the Z-Wave device LHC5020, manufactured by Logic Home Control with the thing type UID of logic_lhc5020_00_000
.
The device is in the category of Radiator Control, defining Controls on radiators used to heat up rooms.
The LHC5020 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
This device can be used for controlling standard floor heating valves
Inclusion Information
1.) Set your ZWave controller in inclusion mode
2.) Press the inclusion button on the LHC5020 device three times quickly
3.) The diode will blink to confirm the inclusion is done
Exclusion Information
1.) Set your ZWave controller in exclusion mode
2.) Press the inclusion button on the LHC5020 device three times quickly
3.) The diode will blink to confirm the exclusion is done
Reset the device
The device can be reset by holding down the inclusion button for 10 sec.
Channels
The following table summarises the channels available for the LHC5020 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Dimmer | switch_dimmer | DimmableLight | Dimmer |
Switch 1 | switch_binary1 | Switch | Switch |
Switch 2 | switch_binary2 | Switch | Switch |
Switch 3 | switch_binary3 | Switch | Switch |
Switch 4 | switch_binary4 | Switch | Switch |
Switch 5 | switch_binary5 | Switch | Switch |
Switch 6 | switch_binary6 | Switch | Switch |
Switch 7 | switch_binary7 | Switch | Switch |
Switch 8 | switch_binary8 | Switch | Switch |
Switch 9 | switch_binary9 | Switch | Switch |
Switch 10 | switch_binary10 | Switch | Switch |
Switch 11 | switch_binary11 | Switch | Switch |
Switch 12 | switch_binary12 | Switch | Switch |
Switch 13 | switch_binary13 | Switch | Switch |
Switch 14 | switch_binary14 | Switch | Switch |
Switch
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
Switch 1
Switch the power on and off.
The switch_binary1
channel supports the Switch
item and is in the Switch
category.
Switch 2
Switch the power on and off.
The switch_binary2
channel supports the Switch
item and is in the Switch
category.
Switch 3
Switch the power on and off.
The switch_binary3
channel supports the Switch
item and is in the Switch
category.
Switch 4
Switch the power on and off.
The switch_binary4
channel supports the Switch
item and is in the Switch
category.
Switch 5
Switch the power on and off.
The switch_binary5
channel supports the Switch
item and is in the Switch
category.
Switch 6
Switch the power on and off.
The switch_binary6
channel supports the Switch
item and is in the Switch
category.
Switch 7
Switch the power on and off.
The switch_binary7
channel supports the Switch
item and is in the Switch
category.
Switch 8
Switch the power on and off.
The switch_binary8
channel supports the Switch
item and is in the Switch
category.
Switch 9
Switch the power on and off.
The switch_binary9
channel supports the Switch
item and is in the Switch
category.
Switch 10
Switch the power on and off.
The switch_binary10
channel supports the Switch
item and is in the Switch
category.
Switch 11
Switch the power on and off.
The switch_binary11
channel supports the Switch
item and is in the Switch
category.
Switch 12
Switch the power on and off.
The switch_binary12
channel supports the Switch
item and is in the Switch
category.
Switch 13
Switch the power on and off.
The switch_binary13
channel supports the Switch
item and is in the Switch
category.
Switch 14
Switch the power on and off.
The switch_binary14
channel supports the Switch
item and is in the Switch
category.
Device Configuration
The following table provides a summary of the 13 configuration parameters available in the LHC5020. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Diode control | Diode control |
2 | Turn on/off voltage on input terminal 1 | Turn on/off voltage on input terminal 1 |
3 | Turn on/off voltage on input terminal 2 | Turn on/off voltage on input terminal 2 |
4 | Turn on/off voltage on input terminal 3 | Turn on/off voltage on input terminal 3 |
5 | Turn on/off voltage on input terminal 4 | Turn on/off voltage on input terminal 4 |
6 | Prel. filter time on input terminals | Preliminary filter time on input terminals |
7 | Threshold for triggering input | Threshold for triggering input |
8 | Threshold time for triggering input | Threshold time for triggering input |
9 | Function for input terminal 1 | Function for input terminal 1 |
10 | Function for input terminal 2 | Function for input terminal 2 |
11 | Function for input terminal 3 | Function for input terminal 3 |
12 | Function for input terminal 4 | Function for input terminal 4 |
13 | Central Scene notification | Central Scene notification |
Parameter 1: Diode control
Diode control 0 Turned off
1 Turned on (Default)
2 Blinking 1 sec. interval
3 Blinking 0.5 sec. interval The following option values may be configured -:
Value | Description |
---|---|
0 | Turned off |
1 | Turned on |
2 | Blinking 1 sec. interval |
3 | Blinking 0.5 sec. interval |
The manufacturer defined default value is 1
(Turned on).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Turn on/off voltage on input terminal 1
Turn on/off voltage on input terminal 1 If trigger devices on the input terminal needs external power supply, then turn of the voltage on the input terminal.
0 = Voltage off (use external power supply up to 10V)
1 = Voltage on (7.5V) The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 1
(On).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Turn on/off voltage on input terminal 2
Turn on/off voltage on input terminal 2 If trigger devices on the input terminal needs external power supply, then turn of the voltage on the input terminal.
0 = Voltage off (use external power supply up to 10V)
1 = Voltage on (7.5V) The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 1
(On).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Turn on/off voltage on input terminal 3
Turn on/off voltage on input terminal 3 If trigger devices on the input terminal needs external power supply, then turn of the voltage on the input terminal.
0 = Voltage off (use external power supply up to 10V)
1 = Voltage on (7.5V) The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 1
(On).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: Turn on/off voltage on input terminal 4
Turn on/off voltage on input terminal 4 If trigger devices on the input terminal needs external power supply, then turn of the voltage on the input terminal.
0 = Voltage off (use external power supply up to 10V)
1 = Voltage on (7.5V) The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 1
(On).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 6: Prel. filter time on input terminals
Preliminary filter time on input terminals Time in 10x milliseconds. E.g. 5 = 50 ms. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Parameter 7: Threshold for triggering input
Threshold for triggering input In 10x milliseconds, e.g. 5 = 50 ms, meaning that the voltage on the input terminals need to be stable for more than 50 ms behold the input is counted as activated. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 20
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Parameter 8: Threshold time for triggering input
Threshold time for triggering input Time in 10x miliseconds that an input need to be activated before it is counted as activated. E.g. 50 = 500 ms. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Parameter 9: Function for input terminal 1
Function for input terminal 1 0 = Inactive
1 = Level controlled
2 = Back edge controlled
3 = Front edge controlled. Values in the range 0 to 3 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Parameter 10: Function for input terminal 2
Function for input terminal 2 0 = Inactive
1 = Level controlled
2 = Back edge controlled
3 = Front edge controlled. Values in the range 0 to 3 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Parameter 11: Function for input terminal 3
Function for input terminal 3 0 = Inactive
1 = Level controlled
2 = Back edge controlled
3 = Front edge controlled. Values in the range 0 to 3 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Parameter 12: Function for input terminal 4
Function for input terminal 4 0 = Inactive
1 = Level controlled
2 = Back edge controlled
3 = Front edge controlled. Values in the range 0 to 3 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Parameter 13: Central Scene notification
Central Scene notification Send Central Scene notification when the 4 input terminals gets activated.
0 = Notification off
1 = Notification on Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The LHC5020 supports 14 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Group 1 Gruppe 1 / 1
Lifeline. Gælder for hele modulet.
Maks. antal enheder i gruppen: 1
Gruppe 2 / 2
Sender Basic Report On / Off når udgang 1 bliver aktiveret.
Denne gruppe benyttes typisk til at sende status information til den centrale kontroller enhed, for visualisering af status for udgangen (f.eks. til VERA eller Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Association group 1 supports 5 nodes.
Group 2: Group 2
Group 2 Enhed 2 (End Point 2)
Udgang 2
Gruppe 1 / -
Lifeline.
Maks. antal enheder i gruppen: 0
Gruppe 2 / 3
Sender Basic Report On / Off når udgang 2 bliver aktiveret.
Denne gruppe benyttes typisk til at sende status information til den centrale kontroller enhed, for visualisering af status for udgangen (f.eks. til VERA eller Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Association group 2 supports 5 nodes.
Group 3: Group 3
Group 3 Enhed 3 (End Point 3)
Udgang 3
Gruppe 1 / -
Lifeline.
Maks. antal enheder i gruppen: 0
Gruppe 2 / 4
Sender Basic Report On / Off når udgang 3 bliver aktiveret.
Denne gruppe benyttes typisk til at sende status information til den centrale kontroller enhed, for visualisering af status for udgangen (f.eks. til VERA eller Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Association group 3 supports 5 nodes.
Group 4: Group 4
Group 4 Enhed 4 (End Point 4)
Udgang 4
Gruppe 1 / -
Lifeline.
Maks. antal enheder i gruppen: 0
Gruppe 2 / 5
Sender Basic Report On / Off når udgang 4 bliver aktiveret.
Denne gruppe benyttes typisk til at sende status information til den centrale kontroller enhed, for visualisering af status for udgangen (f.eks. til VERA eller Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Association group 4 supports 5 nodes.
Group 5: Group 5
Group 5 Enhed 5 (End Point 5)
Udgang 5
Gruppe 1 / -
Lifeline.
Maks. antal enheder i gruppen: 0
Gruppe 2 / 6
Sender Basic Report On / Off når udgang 5 bliver aktiveret.
Denne gruppe benyttes typisk til at sende status information til den centrale kontroller enhed, for visualisering af status for udgangen (f.eks. til VERA eller Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Association group 5 supports 5 nodes.
Group 6: Group 6
Group 6 Enhed 6 (End Point 6)
Udgang 6
Gruppe 1 / -
Lifeline.
Maks. antal enheder i gruppen: 0
Gruppe 2 / 7
Sender Basic Report On / Off når udgang 6 bliver aktiveret.
Denne gruppe benyttes typisk til at sende status information til den centrale kontroller enhed, for visualisering af status for udgangen (f.eks. til VERA eller Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Association group 6 supports 5 nodes.
Group 7: Group 7
Group 7 Enhed 7 (End Point 7)
Udgang 7
Gruppe 1 / -
Lifeline.
Maks. antal enheder i gruppen: 0
Gruppe 2 / 8
Sender Basic Report On / Off når udgang 7 bliver aktiveret.
Denne gruppe benyttes typisk til at sende status information til den centrale kontroller enhed, for visualisering af status for udgangen (f.eks. til VERA eller Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Association group 7 supports 5 nodes.
Group 8: Group 8
Group 8 Enhed 8 (End Point 8)
Udgang 8
Gruppe 1 / -
Lifeline.
Maks. antal enheder i gruppen: 0
Gruppe 2 / 9
Sender Basic Report On / Off når udgang 8 bliver aktiveret.
Denne gruppe benyttes typisk til at sende status information til den centrale kontroller enhed, for visualisering af status for udgangen (f.eks. til VERA eller Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Association group 8 supports 5 nodes.
Group 9: Group 9
Group 9 Enhed 9 (End Point 9)
Udgang 9
Gruppe 1 / -
Lifeline.
Maks. antal enheder i gruppen: 0
Gruppe 2 / 10
Sender Basic Report On / Off når udgang 9 bliver aktiveret.
Denne gruppe benyttes typisk til at sende status information til den centrale kontroller enhed, for visualisering af status for udgangen (f.eks. til VERA eller Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Association group 9 supports 5 nodes.
Group 10: Group 10
Group 10 Enhed 10 (End Point 10)
Udgang 10
Gruppe 1 / -
Lifeline.
Maks. antal enheder i gruppen: 0
Gruppe 2 / 11
Sender Basic Report On / Off når udgang 10 bliver aktiveret.
Denne gruppe benyttes typisk til at sende status information til den centrale kontroller enhed, for visualisering af status for udgangen (f.eks. til VERA eller Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Association group 10 supports 5 nodes.
Group 11: Group 11
Group 11 Enhed 11 (End Point 11)
Indgang 1
Gruppe 1 / -
Lifeline.
Maks. antal enheder i gruppen: 0
Gruppe 2 / 12
Sender Basic Report On / Off når indgang 1 aktiveres.
Denne gruppe benyttes typisk til at sende status information til den centrale kontroller enhed, for visualisering af status for indgangen (f.eks. til VERA eller Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Gruppe 3 / 13
Sender Basic Set On / Off når indgang 1 bliver aktiveret.
Kan f.eks. bruges til at styre relæmoduler, eller til visualisering i den centrale kontroller enhed (f.eks. Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Gruppe 4 / 14
Sender Binary Switch Set On / Off når indgang 1 bliver aktiveret.
Kan f.eks. bruges til at styre relæmoduler.
Maks. antal enheder i gruppen: 5
Gruppe 5 / 15
Sender Multilevel Switch Set / Multilevel Switch Start Level Change / Multilevel Switch Stop Level Change når indgang 1 bliver aktiveret.
Kan typisk benyttes til at styre lysdæmpere, gardin styringer, m.m.
Maks. antal enheder i gruppen: 5
Association group 11 supports 5 nodes.
Group 12: Group 12
Group 12 Enhed 12 (End Point 12)
Indgang 2
Gruppe 1 / -
Lifeline.
Maks. antal enheder i gruppen: 0
Gruppe 2 / 16
Sender Basic Report On / Off når indgang 2 aktiveres.
Denne gruppe benyttes typisk til at sende status information til den centrale kontroller enhed, for visualisering af status for indgangen (f.eks. til VERA eller Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Gruppe 3 / 17
Sender Basic Set On / Off når indgang 2 bliver aktiveret.
Kan f.eks. bruges til at styre relæmoduler, eller til visualisering i den centrale kontroller enhed (f.eks. Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Gruppe 4 / 18
Sender Binary Switch Set On / Off når indgang 2 bliver aktiveret.
Kan f.eks. bruges til at styre relæmoduler.
Maks. antal enheder i gruppen: 5
Gruppe 5 / 19
Sender Multilevel Switch Set / Multilevel Switch Start Level Change / Multilevel Switch Stop Level Change når indgang 2 bliver aktiveret.
Kan typisk benyttes til at styre lysdæmpere, gardin styringer, m.m.
Maks. antal enheder i gruppen: 5
Association group 12 supports 5 nodes.
Group 13: Group 13
Group 13 Enhed 13 (End Point 13)
Indgang 3
Gruppe 1 / -
Lifeline.
Maks. antal enheder i gruppen: 0
Gruppe 2 / 20
Sender Basic Report On / Off når indgang 3 aktiveres.
Denne gruppe benyttes typisk til at sende status information til den centrale kontroller enhed, for visualisering af status for indgangen (f.eks. til VERA eller Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Gruppe 3 / 21
Sender Basic Set On / Off når indgang 3 bliver aktiveret.
Kan f.eks. bruges til at styre relæmoduler, eller til visualisering i den centrale kontroller enhed (f.eks. Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Gruppe 4 / 22
Sender Binary Switch Set On / Off når indgang 3 bliver aktiveret.
Kan f.eks. bruges til at styre relæmoduler.
Maks. antal enheder i gruppen: 5
Gruppe 5 / 23
Sender Multilevel Switch Set / Multilevel Switch Start Level Change / Multilevel Switch Stop Level Change når indgang 3 bliver aktiveret.
Kan typisk benyttes til at styre lysdæmpere, gardin styringer, m.m.
Maks. antal enheder i gruppen: 5
Association group 13 supports 5 nodes.
Group 14: Group 14
Group 14 Enhed 14 (End Point 14)
Indgang 4
Gruppe 1 / -
Lifeline.
Maks. antal enheder i gruppen: 0
Gruppe 2 / 24
Sender Basic Report On / Off når indgang 4 aktiveres.
Denne gruppe benyttes typisk til at sende status information til den centrale kontroller enhed, for visualisering af status for indgangen (f.eks. til VERA eller Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Gruppe 3 / 25
Sender Basic Set On / Off når indgang 4 bliver aktiveret.
Kan f.eks. bruges til at styre relæmoduler, eller til visualisering i den centrale kontroller enhed (f.eks. Fibaro Home Center).
Maks. antal enheder i gruppen: 5
Gruppe 4 / 26
Sender Binary Switch Set On / Off når indgang 4 bliver aktiveret.
Kan f.eks. bruges til at styre relæmoduler.
Maks. antal enheder i gruppen: 5
Gruppe 5 / 27
Sender Multilevel Switch Set / Multilevel Switch Start Level Change / Multilevel Switch Stop Level Change når indgang 4 bliver aktiveret.
Kan typisk benyttes til at styre lysdæmpere, gardin styringer, m.m.
Maks. antal enheder i gruppen: 5
Association group 14 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Endpoint 1
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Endpoint 2
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Endpoint 3
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Endpoint 4
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Endpoint 5
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Endpoint 6
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Endpoint 7
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Endpoint 8
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Endpoint 9
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Endpoint 10
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Endpoint 11
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Endpoint 12
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Endpoint 13
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Endpoint 14
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.