DP-32 / IX-30 / IX-32 PIR Sensor
This describes the Z-Wave device * DP-32 / IX-30 / IX-32*, manufactured by Kaipule Technology Co., Ltd. with the thing type UID of kaipule_ix32_06_000
.
This version of the device is limited to firmware versions above 6.0
The DP-32 / IX-30 / IX-32 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The DP-32 / IX-30 / IX-32 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
Overview
The hardware board for the IX30 (wall) and IX32 (ceiling) is the same thing and reports the same Type and ID.
Wakeup Information
The DP-32 / IX-30 / IX-32 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Channels
The following table summarises the channels available for the DP-32 / IX-30 / IX-32 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Binary Sensor | sensor_binary | Door | Switch |
Motion Alarm | alarm_motion | Door | Switch |
Tamper Alarm | alarm_tamper | Switch | |
Battery Level | battery-level | Battery | Number |
Binary Sensor
Indicates if a sensor has triggered.
The sensor_binary
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Motion Alarm
Indicates if a motion alarm is triggered.
The alarm_motion
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Tamper Alarm
Indicates if the tamper alarm is triggered.
The alarm_tamper
channel supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
Device Configuration
The following table provides a summary of the 3 configuration parameters available in the DP-32 / IX-30 / IX-32. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Basic Set | If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value command to control that deivce when the PIR is triggered. |
2 | Turn Off Light Time Configuration | If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value command to Group 2 and send Basic Set = 0x00 to turn of light after 5 x t seconds- Set value t means to send the BAsic Set command after t seconds. |
3 | PIR Sensor Alarm Elemination Time Configuration | Min time is 5s. Eg If the config is 1, this means it will eliminate alarm after 1 * 5s = 5 seconds |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Parameter 1: Basic Set
If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value command to control that deivce when the PIR is triggered. If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value command to control that deivce when the PIR is triggered. Values in the range 1 to 100 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Turn Off Light Time Configuration
If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value command to Group 2 and send Basic Set = 0x00 to turn of light after 5 x t seconds- Set value t means to send the BAsic Set command after t seconds. If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value command to Group 2 and send Basic Set = 0x00 to turn of light after 5 x t seconds- Set value t means to send the BAsic Set command after t seconds. Values in the range 1 to 120 may be set.
The manufacturer defined default value is 20
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: PIR Sensor Alarm Elemination Time Configuration
Min time is 5s. Eg If the config is 1, this means it will eliminate alarm after 1 * 5s = 5 seconds The selected value is multiplied with 5. After this time the sensor will report PIR OFF.
E.g. If you select value --> 3 * 5s = 15 seconds.
The Sensor will report PIR Off after 15 seconds. Values in the range 1 to 120 may be set.
The manufacturer defined default value is 20
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Wakeup Interval
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DP-32 / IX-30 / IX-32 supports 2 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Send "notification_Report" to the device in Life line group
Association group 1 supports 1 node.
Group 2: Basic Set Command
When sensor is triggered:
[Command Class BAsic, Basic Set, Value = 0xFF(default 0xFF, configurable, see Config Parameters)
When light up timeout:
[Command Class BAsic, BAsic Set, Value =0x00]
Association group 2 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V2 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |