5.7 KiB
layout | title |
---|---|
documentation | NZW36 - ZWave |
{% include base.html %}
NZW36 On/Off Smart Plug + Signal Repeater (Z-Wave Plus)
This describes the Z-Wave device NZW36, manufactured by Inovelli with the thing type UID of inovelli_nzw36_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The NZW36 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Plug the Smart Outlet in. Sync. Control Lights & Appliances from Anywhere.
Control your lights and appliances with the Inovelli® Z-Wave Plus plug-in on/off smart outlet. In addition to being able to remotely control your devices, this smart plug also acts as a Z-Wave signal booster (repeater), giving you best of both worlds.
Inclusion Information
Alright, let’s include your device!
Including Steps:
- Go ahead and put your HUB/Gateway in inclusion/pairing mode
- While your HUB/Gateway is in inclusion mode, press the Middle Button on the front of your NZW36 five (5) times rapidly within 1-2 seconds
Check to make sure your device turns on and off and if so, congratulations, you now have remote control over your lights!
STILL CAN’T GET IT TO PAIR? You may need to exclude the device first. While this is rare, sometimes it happens. Please click see the, “Exclusion / Device Removal” section below. Once that’s completed, please return here.
**If you are having issues pairing your device, please make sure you are within range above. If you are confident you are, please click on the, “Exclusion / Device Removal” tab below to exclude your device first**
Exclusion Information
Please follow the below directions to exclude/remove your smart plug from your HUB/Gateway.
Exclusion/Removal Steps:
- Put your HUB/Gateway in exclusion/removal mode
- Press the Middle Button on the front of your NZW36 five (5) times rapidly (within 1-2 seconds)
Your smart plug should now be removed from your HUB/Gateway.
**If you are having issues removing your device, try removing the device directly next to the HUB. This will solve 95% of all problems you may have when removing**
Channels
The following table summarises the channels available for the NZW36 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Scene Number | scene_number | Number | |
Alarm | alarm_general | Door | Switch |
Switch
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
Alarm
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Device Configuration
The device has no configuration parameters defined.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The NZW36 supports 1 association group.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V3 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.