GE 14295 In-Wall Dimmer Switch
This describes the Z-Wave device GE 14295, manufactured by Jasco Products with the thing type UID of ge_ge14295_00_000
.
The GE 14295 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Inclusion Information
-
Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network.
-
Once the controller is ready to include your device, press and release the top or bottom of the wireless smart dimmer(rocker) to include it in the network.
Exclusion Information
-
Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network.
-
Once the controller is ready to Exclude your device, press and release the top or bottom of the wireless smart dimmer (rocker) to exclude it from the network.
Channels
The following table summarises the channels available for the GE 14295 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | Number |
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel supports the Number
item.
Device Configuration
The following table provides a summary of the 7 configuration parameters available in the GE 14295. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
4 | Invert Switch | Invert the ON/OFF Switch State. |
7 | Dim Rate Adjustments | Number of steps or levels |
8 | Dim Rate Adjustments | Timing of steps or levels |
9 | Dim Rate Adjustments | Number of steps or levels |
10 | Dim Rate Adjustments | Timing of steps |
11 | Dim Rate Adjustments | Number of steps or levels |
12 | Dim Rate Adjustments | Timing of steps or levels |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 4: Invert Switch
Invert the ON/OFF Switch State.
The following option values may be configured -:
Value | Description |
---|---|
0 | (Default) No |
1 | Yes |
The manufacturer defined default value is 0
((Default) No).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 7: Dim Rate Adjustments
Number of steps or levels
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Parameter 8: Dim Rate Adjustments
Timing of steps or levels
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_8_2
and is of type INTEGER
.
Parameter 9: Dim Rate Adjustments
Number of steps or levels
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Parameter 10: Dim Rate Adjustments
Timing of steps
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_10_2
and is of type INTEGER
.
Parameter 11: Dim Rate Adjustments
Number of steps or levels
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Parameter 12: Dim Rate Adjustments
Timing of steps or levels
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_12_2
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The GE 14295 supports 3 association groups.
Group 1: Association Group 1
Z-Wave Plus Lifeline, Multilevel Switch Report
Association group 1 supports 5 nodes.
Group 2: Association Group 2
Supports Basic Set and is controlled with the local load
Association group 2 supports 5 nodes.
Group 3: Association Group 3
Supports Basic Set and is controlled by double pressing the On or Off button
Association group 3 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |