20 KiB
layout | title |
---|---|
documentation | FGRGBW - ZWave |
{% include base.html %}
FGRGBW RGBW Controller
This describes the Z-Wave device FGRGBW, manufactured by Fibargroup with the thing type UID of fibaro_fgrgbw_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The FGRGBW supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
No device information is provided in the database. Consider updating the database to improve the documentation.
Channels
The following table summarises the channels available for the FGRGBW -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Dimmer | switch_dimmer | DimmableLight | Dimmer |
Sensor (power) | sensor_power | Energy | Number |
Electric meter (watts) | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | Energy | Number |
Color | color_color | Color | |
Start animation | scene_number | Number | |
Red | switch_dimmer2 | DimmableLight | Dimmer |
Green | switch_dimmer3 | DimmableLight | Dimmer |
Blue | switch_dimmer4 | DimmableLight | Dimmer |
White | switch_dimmer5 | DimmableLight | Dimmer |
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
Sensor (power)
Indicates the energy consumption (kWh).
The sensor_power
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (watts)
Indicates the instantaneous power consumption.
The meter_watts
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (kWh)
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Color
The color channel allows to control the color of a light. It is also possible to dim values and switch the light on and off.
The color_color
channel supports the Color
item.
Start animation
Triggers when a scene button is pressed.
The scene_number
channel supports the Number
item.
Red
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer2
channel supports the Dimmer
item and is in the DimmableLight
category.
Green
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer3
channel supports the Dimmer
item and is in the DimmableLight
category.
Blue
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer4
channel supports the Dimmer
item and is in the DimmableLight
category.
White
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer5
channel supports the Dimmer
item and is in the DimmableLight
category.
Device Configuration
The following table provides a summary of the 20 configuration parameters available in the FGRGBW. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | ALL ON / ALL OFF function activation | Activation/deactivation of ALL ON/ALL OFF functions. |
6 | Associations command class choice | Associations command class choice. By default, Normal (Dimmer) - BASIC_SET/SWITCH_MULTILEVEL_START/STOP. Default setting: Normal (Dimmer) - BASIC_SET/SWITCH_MULTILEVEL_START/STOP |
8 | Outputs state change mode | MODE1, Example: change saturation level from 0% to 99% Parameter 9: Step = 5 Parameter 10: Time between steps: 10ms. Default setting: MODE1 |
9 | Step value (relevant for MODE1) | Step value (relevant for MODE1). |
Default setting: 1 | ||
Available settings: 1 - 255. | ||
10 | Time between steps (relevant for MODE1) | Time between steps (relevant for MODE1). |
Default setting: 10 ms | ||
0 - immediate change of state | ||
Available settings: 1 - 60000 ms. | ||
11 | Time for changing from start to end value | Step value (relevant for MODE1). |
Default setting: 67 (3s) | ||
0: immediate change | ||
1-63: 20-126 [ms] value*20ms | ||
65-127: 1-63 [s] (value-64)*1s | ||
129-191: 10-630 [s] (value-128)*10s | ||
12 | Maximum Brightening level | Maximum Brightening level. |
Default setting: 255 | ||
Available settings: 3 - 255. | ||
13 | Minimum dim level | Minimum dim level. Default setting: 2 Available settings: 3 - 255. |
14 | Inputs/Outputs configuration - relevant for main controllers other than Home Center 2 only | Inputs/Outputs configuration - relevant for main controllers other than Home Center 2 only. |
Default setting: 4369 | ||
Controlled device: RGBW, toggle switch inputs (NORMAL MODE). | ||
16 | Remember device status after power failure | Define how will the Plug react after the power supply is back on. Default setting: 1 Available settings: 0 - Device does not memorize its state aft |
30 | Alarm of any type (General alarm, flood alarm, smoke alarm: CO, CO2, temperature alarm.) | Alarm of any type (General alarm, flood alarm, smoke alarm: CO, CO2, temperature alarm.) Default setting: INACTIVE |
38 | Alarm sequence program | Alarm sequence program. |
Default setting: 10 | ||
1-10 specifies alarm program number. | ||
39 | Active PROGRAM alarm time | IActive PROGRAM alarm time. |
Default setting: 600s | ||
1-65534 specifies alarm time in seconds. | ||
42 | Command class reporting Outputs status change | Command class reporting Outputs status change. Default setting: 0 |
43 | Reporting 0-10v analog inputs change threshold | Parameter defines a value by which input voltage must change in order to be reported to the main controller. |
New value is calculated based on last reported value. | ||
Default setting: 5 | ||
44 | Power load reporting frequency | Parameter defines Time between reports. The report will be sent if last reported value differs from the current value, else reports will also be sent in case of polling. |
Default setting: 3 600 (s) | ||
45 | Reporting Changes in energy consumed by controlled devices | Defines the required change in power to generate an unsolicited power report. |
New, reported energy value is calculated based on last reported value. | ||
Default setting: 10 (0,1 kWh). | ||
71 | Response to BRIGHTNESS set to 0% | Response to BRIGHTNESS set to 0%. Default setting: 1 |
72 | Starting animation program | Starting animation programm. Starting predefined program when device set to work in RGB/RGBW mode (parameter 14) - relevant for main controllers other than Home Center 2 only. Default setting: 1 |
73 | Triple click action | Triple click action. Default setting: 0 |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 1: ALL ON / ALL OFF function activation
Activation/deactivation of ALL ON/ALL OFF functions. By default, ALL ON active ALL OFF active. The following option values may be configured -:
Value | Description |
---|---|
-1 | ALL ON active ALL OFF active |
0 | ALL ON inactive ALL OFF inactive |
1 | ALL ON inactive ALL OFF active |
2 | ALL ON active ALL OFF inactive |
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 6: Associations command class choice
Associations command class choice. By default, Normal (Dimmer) - BASIC_SET/SWITCH_MULTILEVEL_START/STOP. Default setting: Normal (Dimmer) - BASIC_SET/SWITCH_MULTILEVEL_START/STOP
The following option values may be configured -:
Value | Description |
---|---|
0 | Normal (Dimmer) - BASIC_SET/SWITCH_MULTILEVEL_START/STOP |
1 | Normal (RGBW) - COLOR_CONTROL_SET/START/STOP_STATE_CHANGE |
2 | Normal (RGBW) - COLOR_CONTROL_SET |
3 | Brightness - BASIC_SET/SWITCH_MULTILEVEL_START/STOP |
4 | Rainbow (RGBW) - COLOR_CONTROL_SET |
The manufacturer defined default value is 0
(Normal (Dimmer) - BASIC_SET/SWITCH_MULTILEVEL_START/STOP).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Parameter 8: Outputs state change mode
MODE1, Example: change saturation level from 0% to 99% Parameter 9: Step = 5 Parameter 10: Time between steps: 10ms. Default setting: MODE1
The following option values may be configured -:
Value | Description |
---|---|
0 | MODE1 (related parameters: 9-step value, 10-time between steps) |
1 | MODE2 (related parameters: 11-time to change value, relevant for RGB/R |
The manufacturer defined default value is 0
(MODE1 (related parameters: 9-step value, 10-time between steps)).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Parameter 9: Step value (relevant for MODE1)
Step value (relevant for MODE1).
Default setting: 1
Available settings: 1 - 255.
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Parameter 10: Time between steps (relevant for MODE1)
Time between steps (relevant for MODE1).
Default setting: 10 ms
0 - immediate change of state
Available settings: 1 - 60000 ms.
Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_10_2
and is of type INTEGER
.
Parameter 11: Time for changing from start to end value
Step value (relevant for MODE1).
Default setting: 67 (3s)
0: immediate change
1-63: 20-126 [ms] value*20ms
65-127: 1-63 [s] (value-64)*1s
129-191: 10-630 [s] (value-128)*10s
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 67
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Parameter 12: Maximum Brightening level
Maximum Brightening level.
Default setting: 255
Available settings: 3 - 255.
Values in the range 3 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Parameter 13: Minimum dim level
Minimum dim level. Default setting: 2 Available settings: 3 - 255.
Values in the range 2 to 255 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Parameter 14: Inputs/Outputs configuration - relevant for main controllers other than Home Center 2 only
Inputs/Outputs configuration - relevant for main controllers other than Home Center 2 only.
Default setting: 4369
Controlled device: RGBW, toggle switch inputs (NORMAL MODE).
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 4369
.
This parameter has the configuration ID config_14_2
and is of type INTEGER
.
Parameter 16: Remember device status after power failure
Define how will the Plug react after the power supply is back on. Default setting: 1 Available settings: 0 - Device does not memorize its state aft
The following option values may be configured -:
Value | Description |
---|---|
0 | Do not remember state |
1 | Remember state before power failure |
The manufacturer defined default value is 1
(Remember state before power failure).
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
Parameter 30: Alarm of any type (General alarm, flood alarm, smoke alarm: CO, CO2, temperature alarm.)
Alarm of any type (General alarm, flood alarm, smoke alarm: CO, CO2, temperature alarm.) Default setting: INACTIVE
The following option values may be configured -:
Value | Description |
---|---|
0 | INACTIVE - the device doesn't respond to alarm frames |
1 | ALARM ON - the device turns on once alarm is detected (all channels se |
2 | ALARM OFF - the device turns off once alarm is detected (all channels |
3 | ALARM PROGRAM - alarm sequence turns on (program selected in parameter |
The manufacturer defined default value is 0
(INACTIVE - the device doesn't respond to alarm frames).
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Parameter 38: Alarm sequence program
Alarm sequence program.
Default setting: 10
1-10 specifies alarm program number.
Values in the range 1 to 10 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_38_1
and is of type INTEGER
.
Parameter 39: Active PROGRAM alarm time
IActive PROGRAM alarm time.
Default setting: 600s
1-65534 specifies alarm time in seconds.
Values in the range 1 to 65534 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_39_2
and is of type INTEGER
.
Parameter 42: Command class reporting Outputs status change
Command class reporting Outputs status change. Default setting: 0
The following option values may be configured -:
Value | Description |
---|---|
0 | Reporting as a result of inputs and controllers actions (SWITCH MULTIL |
1 | Reporting as a result of inputs actions (SWITCH MULTILEVEL) |
2 | Reporting as a result of inputs actions (COLOR CONTROL) |
The manufacturer defined default value is 0
(Reporting as a result of inputs and controllers actions (SWITCH MULTIL).
This parameter has the configuration ID config_42_1
and is of type INTEGER
.
Parameter 43: Reporting 0-10v analog inputs change threshold
Parameter defines a value by which input voltage must change in order to be reported to the main controller.
New value is calculated based on last reported value.
Default setting: 5
Values in the range 1 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_43_1
and is of type INTEGER
.
Parameter 44: Power load reporting frequency
Parameter defines Time between reports. The report will be sent if last reported value differs from the current value, else reports will also be sent in case of polling.
Default setting: 3 600 (s)
Values in the range 1 to 65534 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_44_2
and is of type INTEGER
.
Parameter 45: Reporting Changes in energy consumed by controlled devices
Defines the required change in power to generate an unsolicited power report.
New, reported energy value is calculated based on last reported value.
Default setting: 10 (0,1 kWh).
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_45_1
and is of type INTEGER
.
Parameter 71: Response to BRIGHTNESS set to 0%
Response to BRIGHTNESS set to 0%. Default setting: 1
The following option values may be configured -:
Value | Description |
---|---|
0 | illumination colour set to white (all channels controlled together) |
1 | last set colour is memorized |
The manufacturer defined default value is 1
(last set colour is memorized).
This parameter has the configuration ID config_71_1
and is of type INTEGER
.
Parameter 72: Starting animation program
Starting animation programm. Starting predefined program when device set to work in RGB/RGBW mode (parameter 14) - relevant for main controllers other than Home Center 2 only. Default setting: 1
Values in the range 1 to 10 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_72_1
and is of type INTEGER
.
Parameter 73: Triple click action
Triple click action. Default setting: 0
The following option values may be configured -:
Value | Description |
---|---|
0 | NODE INFO control frame is sent |
1 | starting favourite program |
The manufacturer defined default value is 0
(NODE INFO control frame is sent).
This parameter has the configuration ID config_73_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The FGRGBW supports 5 association groups.
Group 1: Assigned to IN1 input
Association group 1 supports 5 nodes.
Group 2: Assigned to IN2 input
Association group 2 supports 5 nodes.
Group 3: Assigned to IN3 input
Association group 3 supports 5 nodes.
Group 4: Assigned to IN4 input
Association group 4 supports 5 nodes.
Group 5: Reports device status
Association group 5 supports 1 node.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V2 | |
COMMAND_CLASS_METER_V2 | |
COMMAND_CLASS_SWITCH_COLOR_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Endpoint 1
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
Endpoint 2
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
Endpoint 3
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
Endpoint 4
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
Endpoint 5
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
Documentation Links