VMZ Solar z-wave plus Awning Blind z-wave plus version
This describes the Z-Wave device VMZ Solar z-wave plus, manufactured by Fakro with the thing type UID of fakro_vmzsolarplus_00_000
.
The VMZ Solar z-wave plus supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Overview
No device information is provided in the database. Consider updating the database to improve the documentation.
Channels
The following table summarises the channels available for the VMZ Solar z-wave plus -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Blinds control | blinds_control | Blinds | Rollershutter |
Alarm (power) | alarm_power | Door | Switch |
Battery Level | battery-level | Battery | Number |
Switch
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Blinds control
Provides start / stop control of blinds.
The blinds_control
channel supports the Rollershutter
item and is in the Blinds
category.
Alarm (power)
Indicates if a power alarm is triggered.
The alarm_power
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
Device Configuration
The following table provides a summary of the 15 configuration parameters available in the VMZ Solar z-wave plus. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | operating mode | operating mode |
2 | winter mode | Summer/Winter mode |
3 | Delay time | delay to auto shade |
4 | Level of sensitivity for day | Level of insolation to open/close the shades |
5 | Temperature | Temperature |
6 | STM active | STM AutoShade active |
13 | Restore last position | Restore last position |
17 | Insolation level | Current on autoshade solar panel |
21 | Motor current | Motor current |
77 | CLOSE current | CLOSE current |
78 | OPEN current | OPEN current |
79 | CLOSE overload current | CLOSE overload current |
80 | OPEN overload current | OPEN overload current |
99 | Restore default config values | Restore default config values |
100 | Autoexclude | Autoexclude |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 1: operating mode
operating mode Operating mode. Available values:
0 - manual
1 - semiauto: goes down automatically but does not go up.
2 - auto The following option values may be configured -:
Value | Description |
---|---|
0 | manual |
1 | semiauto |
2 | auto |
The manufacturer defined default value is 0
(manual).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: winter mode
Summer/Winter mode summer mode: go down if sun shines and go up if it is cloudy
winter mode: if temperature is below 0 deg C and sun shines then go up if it is cloudy go down. If temperature is above 0 deg C works as a summer mode The following option values may be configured -:
Value | Description |
---|---|
1 | summer mode only |
2 | winter mode |
The manufacturer defined default value is 1
(summer mode only).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Delay time
delay to auto shade Delay time in minutes after which the shade is open or closed in auto mode Values in the range 0 to 30 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Level of sensitivity for day
Level of insolation to open/close the shades Level of insolation in mA to open/close the shades in the auto mode Values in the range 3 to 100 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: Temperature
Temperature T[oC] = x minus 50 Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
This is a read only parameter.
Parameter 6: STM active
STM AutoShade active
The following option values may be configured -:
Value | Description |
---|---|
0 | no |
1 | yes |
The manufacturer defined default value is 0
(no).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Parameter 13: Restore last position
Restore last position Restore last position or always go down till the end. The following option values may be configured -:
Value | Description |
---|---|
1 | go down |
2 | restore last position |
The manufacturer defined default value is 1
(go down).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Parameter 17: Insolation level
Current on autoshade solar panel Current from autoshade solar panel for loading battery: 0 - 255 mA Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
This is a read only parameter.
Parameter 21: Motor current
Motor current Current used by motor: 10[mA] - 2,55[A] Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
This is a read only parameter.
Parameter 77: CLOSE current
CLOSE current CLOSE current: 1[mA] - 255[mA] Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_77_1
and is of type INTEGER
.
Parameter 78: OPEN current
OPEN current OPEN current: 1[mA] - 255[mA] Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_78_1
and is of type INTEGER
.
Parameter 79: CLOSE overload current
CLOSE overload current CLOSE overload current: 10[mA] - 2,55[A] Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_79_1
and is of type INTEGER
.
Parameter 80: OPEN overload current
OPEN overload current OPEN overload current: 10[mA] - 2,55[A] Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_80_1
and is of type INTEGER
.
Parameter 99: Restore default config values
Restore default config values Restore default config values. The following option values may be configured -:
Value | Description |
---|---|
1 | restore default config values |
2 | user values |
The manufacturer defined default value is 2
(user values).
This parameter has the configuration ID config_99_1
and is of type INTEGER
.
Parameter 100: Autoexclude
Autoexclude
The following option values may be configured -:
Value | Description |
---|---|
1 | Off |
2 | On |
The manufacturer defined default value is 1
(off).
This parameter has the configuration ID config_100_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The VMZ Solar z-wave plus supports 4 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
BATTERY
ALARM
DEVICE_RESET_LOCALLY
BASIC
Association group 1 supports 1 node.
Group 2: BasicRepeat
BASIC
Association group 2 supports 5 nodes.
Group 3: MultilevelRepeat
SWITCH_MULTILEVEL
Association group 3 supports 5 nodes.
Group 4: BasicControl
BASIC
Association group 4 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V3 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_NODE_NAMING_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |