openhab-docs/_addons_bindings/zwave/doc/everspring/se812_0_0.md

3.2 KiB

layout title
documentation SE812 - ZWave

{% include base.html %}

SE812 Siren

This describes the Z-Wave device SE812, manufactured by Everspring with the thing type UID of everspring_se812_00_000.

The device is in the category of Siren, defining Siren used by Alarm systems.

SE812 product image

The SE812 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the SE812 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Tamper Switch alarm_smoke Smoke Switch
Battery Level battery-level Battery Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Tamper Switch

Tamper Alarm

Indicates if a smoke is triggered.

The alarm_smoke channel supports the Switch item and is in the Smoke category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The SE812 supports 1 association group.

Group 1: Control/Report Group

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.