19 KiB
layout | title |
---|---|
documentation | ZW099 - ZWave |
{% include base.html %}
ZW099 Smart Dimmer 6
This describes the Z-Wave device ZW099, manufactured by AEON Labs with the thing type UID of aeon_zw099_00_000
.
The ZW099 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing.
Endpoint 1 is used to Set/Get the state of output load.
Endpoint 2 is used to Set/Get the brightness level of RGB LED when it is in Night light mode.
Inclusion Information
- Insert the Smart Dimmer to power socket, The RGB LED will be colorful gradient status.
- Let the primary controller into inclusion mode (If you don’t know how to do this, refer to its manual).
- Press the Action button.
- If the inclusion success, Smart Dimmer LED will be solid. Otherwise, the LED will remain colorful gradient status, in which you need to repeat the process from step 2.
Exclusion Information
- Insert the Smart Dimmer to power socket, The Smart Dimmer LED will be solid.
- Let the primary controller into remove mode (If you don’t know how to do this, refer to its manual).
- Press the Action button.
- If the remove is successful, Smart Dimmer LED will be colorful gradient status. If Smart Dimmer LED still be solid, please repeat the process from step 2.
Channels
The following table summarises the channels available for the ZW099 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Dimmer | switch_dimmer | DimmableLight | Dimmer |
Power Consumption (kWh) | meter_kwh | Energy | Number |
Energy Consumption (watts) | meter_watts | Energy | Number |
Night mode color | color_color | Color |
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
Power Consumption (kWh)
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Energy Consumption (watts)
Indicates the instantaneous power consumption.
The meter_watts
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Night mode color
The color channel allows to control the color of a light. It is also possible to dim values and switch the light on and off.
The color_color
channel supports the Color
item.
Device Configuration
The following table provides a summary of the 22 configuration parameters available in the ZW099. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | Current Overload Protection | Toggle current overload protection |
20 | Initial Load State | Configure the iniital output load state after re-power on |
33 | RGB LED Color Test | Set the RGB LED color value for testing |
80 | Notification on Status Change | Enable notifications for Group 1 device associations. |
81 | LED Indicator Mode | Configure the LED mode. |
83 | LED Color for Night Light | Configure the RGB value when it is in Night light mode |
84 | LED Brightness | Brightness level of RGB LED (0%-100%) |
90 | Enable Report triggered by minimal change of value | Enables/disables parameter 91 and 92 (reporting minimum wattage) |
91 | Minimum Change to send Report (Watt) | The minimum change in wattage value for a report to be sent |
92 | Minimum Change to send Report (%) | The minimum change in wattage percentage for a report to be sent |
100 | Reset Report Assignments for All Groups | Reset the reports to send to each report group to default values. |
101 | Reports for Group 1 | Define which reports to send in report group 1. |
102 | Reports for Group 2 | Define which reports to send in report group 2. |
103 | Reports for Group 3 | Define which reports to send in report group 3. |
110 | Reset Report Time Intervals for All Groups | Reset the reports time interval for each report group to default values. |
111 | Report Group 1 Time Interval | The time interval of sending Report group . |
112 | Report Group 2 Time Interval | The time interval of sending Report group 2. |
113 | Report Group 3 Time Interval | The time interval of sending Report group 3. |
200 | Partner ID | Partner ID (0= Aeon Labs Standard Product, 1= others). |
252 | Configuration Lock | Enable/disable Configuration Lock |
254 | Device Tag | Device Tag |
255 | Reset to Factory Default Settings | Reset to Factory Default Settings |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 3: Current Overload Protection
Toggle current overload protection Output Load will be turned off automatically when the Current overrun 2.6A and the time more than 2 minutes (0=disabled, 1=enabled). The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 20: Initial Load State
Configure the iniital output load state after re-power on Configure the output load status after re-power on (0=last status, 1=always on, 2=always off) The following option values may be configured -:
Value | Description |
---|---|
0 | Last Status |
1 | Always On |
2 | Always Off |
The manufacturer defined default value is 0
(Last Status).
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Parameter 33: RGB LED Color Test
Set the RGB LED color value for testing Set the RGB LED color value for testing (64-bit value).
- Value1: Red value (0-255) (16-bits: 48-63)
- Value2: Green value (0-255) (16-bits: 32-47)
- Value3: Blue value (0-255) (16-bits: 16-31)
- Value4: Reserved (0-255) (16-bits: 0-15)
Example Values:
- Red = -16777216 (0xFF000000)
- Green = 16711680 (0x00FF0000)
- Blue = 65280 (0x0000FF00)
**NOTE:
** In OpenHAB and HABmin (or other Java software) To enter an unsigned integer value greater than 2147483647 you must convert the value to a signed 32-bit value.
Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_33_4
and is of type INTEGER
.
Parameter 80: Notification on Status Change
Enable notifications for Group 1 device associations. Enable to send notifications to associated devices (Group 1) when the state of Smart Dimmer’s load changed (0=nothing, 1=hail CC, 2=basic CC report). The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Hail |
2 | Basic CC Report |
The manufacturer defined default value is 0
(None).
This parameter has the configuration ID config_80_1
and is of type INTEGER
.
Parameter 81: LED Indicator Mode
Configure the LED mode. Configure the state of LED when it is in 3 modes below:
- 0= Energy mode, the LED will follow the status (on/off) of its load.
- 1= Momentary indicate mode, when the state of Dimmer’s load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action.
- 2= Night light mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Energy Mode (Load State) |
1 | Momentary Mode |
2 | Night Light Mode |
The manufacturer defined default value is 0
(Energy Mode (Load State)).
This parameter has the configuration ID config_81_1
and is of type INTEGER
.
Parameter 83: LED Color for Night Light
Configure the RGB value when it is in Night light mode Configure the RGB value when it is in Night light mode. (48-bit value)
- Value1: Red color value (0-255) (16-bits: 32-47)
- Value2: Green color value (0-255) (16-bits: 16-31)
- Value3: Blue color value (0-255) (16-bits: 0-15)
Example Values:
- Blue = 255 (0x0000FF)
- Green = 65280 (0x00FF00)
- Red = 16711680 (0xFF0000)
- White = 1774619 (0xFFFFFF) Values in the range 0 to 16777215 may be set.
The manufacturer defined default value is 1774619
.
This parameter has the configuration ID config_83_3
and is of type INTEGER
.
Parameter 84: LED Brightness
Brightness level of RGB LED (0%-100%) Configure the brightness level of RGB LED (0%-100%) when it is in Energy Mode/momentary indicate mode. (48-bit value)
- Value1: green brightness value. (0-100) (16-bits: 32-47)
- Value2: yellow brightness value. (0-100) (16-bits: 16-31)
- Value3: red brightness value. (0-100) (16-bits: 0-15)
Default value is 50% brightness on all colors: 3289650 (0x323232)
- Green=50 (0x320000)
- Yellow=50 (0x003200)
- Red=50 (0x000032)
Maximum value is 100% brightness on all colors: 6579300 (0x646464)
- Green=100 (0x640000)
- Yellow=100 (0x006400)
- Red=100 (0x000064) Values in the range 0 to 6579300 may be set.
The manufacturer defined default value is 3289650
.
This parameter has the configuration ID config_84_3
and is of type INTEGER
.
Parameter 90: Enable Report triggered by minimal change of value
Enables/disables parameter 91 and 92 (reporting minimum wattage) Enables/disables parameter 91 (minimum change in wattage value) and 92 (minimum change in wattage percent).
Supported values: 1=enabled, 0=disabled The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_90_1_wo
and is of type INTEGER
.
This is a write only parameter.
Parameter 91: Minimum Change to send Report (Watt)
The minimum change in wattage value for a report to be sent The value here represents minimum change in wattage (in terms of wattage) for a REPORT to be sent (Valid values 0- 60000).
Default value: 25 (watts) Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 25
.
This parameter has the configuration ID config_91_2
and is of type INTEGER
.
Parameter 92: Minimum Change to send Report (%)
The minimum change in wattage percentage for a report to be sent The value here represents minimum change in wattage percent (in terms of percentage) for a REPORT to be sent (Valid values 0-100).
Default value: 5 (%) Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_92_1
and is of type INTEGER
.
Parameter 100: Reset Report Assignments for All Groups
Reset the reports to send to each report group to default values.
Reset the reports to send to each report group to default values.
Set configuration parameters 101-103 to default.
See instruction manual for details on reporting configuration.
The following option values may be configured -:
Value | Description |
---|---|
0 | Do Nothing |
1 | Reset to Defaults |
The manufacturer defined default value is 0
(Do Nothing).
This parameter has the configuration ID config_100_1_wo
and is of type INTEGER
.
This is a write only parameter.
Parameter 101: Reports for Group 1
Define which reports to send in report group 1. Which reports need to send in Report group 1 (See flags in user manual).
See instruction manual for details on reporting configuration. Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_101_4
and is of type INTEGER
.
Parameter 102: Reports for Group 2
Define which reports to send in report group 2. Which reports need to send in Report group 2 (See flags in user manual).
See instruction manual for details on reporting configuration. Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_102_4
and is of type INTEGER
.
Parameter 103: Reports for Group 3
Define which reports to send in report group 3. Which reports need to send in Report group 3 (See flags in user manual).
See instruction manual for details on reporting configuration. Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_103_4
and is of type INTEGER
.
Parameter 110: Reset Report Time Intervals for All Groups
Reset the reports time interval for each report group to default values.
Reset the reports to time interval for each report group to default values.
Set configuration parameters 111-113 to default.
See instruction manual for details on reporting configuration.
The following option values may be configured -:
Value | Description |
---|---|
0 | Do Nothing |
1 | Reset to Defaults |
The manufacturer defined default value is 0
(Do Nothing).
This parameter has the configuration ID config_110_1_wo
and is of type INTEGER
.
This is a read only parameter.
This is a write only parameter.
Parameter 111: Report Group 1 Time Interval
The time interval of sending Report group . The time interval of sending Report group 1 (Valid values 0x01-0x7FFFFFFF). Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Parameter 112: Report Group 2 Time Interval
The time interval of sending Report group 2. The time interval of sending Report group 2 (Valid values 0x01-0x7FFFFFFF). Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Parameter 113: Report Group 3 Time Interval
The time interval of sending Report group 3. The time interval of sending Report group 3 (Valid values 0x01-0x7FFFFFFF). Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
Parameter 200: Partner ID
Partner ID (0= Aeon Labs Standard Product, 1= others).
Partner ID
(0= Aeon Labs Standard Product, 1= others).
The following option values may be configured -:
Value | Description |
---|---|
0 | Aeon Labs Standard Product |
1 | Others |
The manufacturer defined default value is 0
(Aeon Labs Standard Product).
This parameter has the configuration ID config_200_1
and is of type INTEGER
.
This is a read only parameter.
Parameter 252: Configuration Lock
Enable/disable Configuration Lock Enable/disable Configuration Locked (0 =disable, 1 = enable). The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_252_1
and is of type INTEGER
.
Parameter 254: Device Tag
Device Tag
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_254_2
and is of type INTEGER
.
Parameter 255: Reset to Factory Default Settings
Reset to Factory Default Settings This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Reset |
The manufacturer defined default value is 0
(Reset).
This parameter has the configuration ID config_255_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZW099 supports 2 association groups.
Group 1: Group 1
Lifeline When the state of Smart Dimmer(on/off/dim the load ) is changed:
- Set Configuration parameter 80 to 0:Reserved (Default).
- Set Configuration parameter 80 to 1:Send Hail CC.
- Set Configuration parameter 80 to 2: Send the Basic Report.
Association group 1 supports 5 nodes.
Group 2: Group 2
Retransmit Forward the Basic Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set to associated nodes in Group 2 when the Smart Dimmer receives the Basic Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set commands from main controller.
Association group 2 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_SWITCH_COLOR_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_V4 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_HAIL_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V1 | |
COMMAND_CLASS_MARK_V1 |
Endpoint 1
Command Class | Comment |
---|---|
COMMAND_CLASS_SWITCH_COLOR_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.