DSC26 Micro Switch G2
This describes the Z-Wave device DSC26, manufactured by AEON Labs with the thing type UID of aeon_dsc26_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The DSC26 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Relay based unit designed to be included inside a junction box to switch a load. Supports external switch.
Inclusion Information
Push case button.
External switch (if attached) can be toggled 10X quickly to include/exclude.
Exclusion Information
Push case button.
External switch (if attached) can be toggled 10X quickly to include/exclude.
Channels
The following table summarises the channels available for the DSC26 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Switch
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Device Configuration
The following table provides a summary of the 15 configuration parameters available in the DSC26. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
2 | LED blink repeat | Number of times LED should blink |
2 | LED duty time | length of time LED will blink on/off per cycle |
80 | Notification on Status Change | Notification on Status Change |
101 | Group 1 report values to send | Group 1 report values to send |
102 | Group 2 report variables to send | Group 2 report variables to send |
103 | Group 3 report variables to send | Group 3 report variables to send |
111 | Interval to send out reports to group 1 | Interval to send out reports to group 1 |
112 | Interval to send out reports to group 2 | Interval to send out reports to group 2 |
113 | Interval to send out reports to group 3 | Interval to send out reports to group 3 |
120 | External Button Type | |
200 | Partner ID | |
250 | CHECK AND DELETE ME formerly parameter 2 | CHECK AND DELETE ME formerly parameter 2 |
252 | Enable/disable Lock Configuration | |
254 | Device Tag | |
255 | Reset configuration set up to default setting | |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 2: LED blink repeat
Number of times LED should blink Number of ON-OFF cycles the LED should complete once set. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_2_000000FF
and is of type INTEGER
.
Parameter 2: LED duty time
length of time LED will blink on/off per cycle LED will turn on and off for this many tenths of a second once set. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_2_0000FF00
and is of type INTEGER
.
Parameter 80: Notification on Status Change
Notification on Status Change Send notification to associated devices in Group 1 when device state changed locally. The following option values may be configured -:
Value | Description |
---|---|
0 | Do nothing |
1 | Hail CC Sent |
2 | Basic CC Report Sent |
The manufacturer defined default value is 0
(Do nothing).
This parameter has the configuration ID config_80_1
and is of type INTEGER
.
Parameter 101: Group 1 report values to send
Group 1 report values to send Value is the sum of the individual parameters:
KWH=8
Wattage=4
Current=2
Voltage=1 Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_101_4
and is of type INTEGER
.
Parameter 102: Group 2 report variables to send
Group 2 report variables to send Value is the sum of the individual parameters:
KWH=8
Wattage=4
Current=2
Voltage=1 Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 8
.
This parameter has the configuration ID config_102_4
and is of type INTEGER
.
Parameter 103: Group 3 report variables to send
Group 3 report variables to send Value is the sum of the individual parameters:
KWH=8
Wattage=4
Current=2
Voltage=1 Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_103_4
and is of type INTEGER
.
Parameter 111: Interval to send out reports to group 1
Interval to send out reports to group 1
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Parameter 112: Interval to send out reports to group 2
Interval to send out reports to group 2
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Parameter 113: Interval to send out reports to group 3
Interval to send out reports to group 3
Values in the range 1 to 2678400 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
Parameter 120: External Button Type
The following option values may be configured -:
Value | Description |
---|---|
0 | Momentary Button |
1 | 2 State Switch |
2 | 3 Way Switch |
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_120_1
and is of type INTEGER
.
Parameter 200: Partner ID
The following option values may be configured -:
Value | Description |
---|---|
0 | Aeon Labs Standard Product |
1 | ATandT |
The manufacturer defined default value is 0
(Aeon Labs Standard Product).
This parameter has the configuration ID config_200_1
and is of type INTEGER
.
Parameter 250: CHECK AND DELETE ME formerly parameter 2
CHECK AND DELETE ME formerly parameter 2 This is a double byte value. The LSB defines the total time the device need to blink. The value if set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s.
CHECK ME!
CHECK ME!
CHECK ME!
CHECK ME!
(did I do this right for parameter 2?) Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_250_2
and is of type INTEGER
.
Parameter 252: Enable/disable Lock Configuration
The following option values may be configured -:
Value | Description |
---|---|
0 | Configuration unlocked |
1 | Configuration locked |
The manufacturer defined default value is 0
(Configuration unlocked).
This parameter has the configuration ID config_252_1
and is of type INTEGER
.
Parameter 254: Device Tag
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_254_2
and is of type INTEGER
.
Parameter 255: Reset configuration set up to default setting
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_255_1_wo
and is of type INTEGER
.
This is a write only parameter.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DSC26 supports 2 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Group 1 will receive hail or basic report (see option 80) when the state of Micro Switch’s load changes.
Association group 1 supports 5 nodes.
Group 2: Retransmit
When the Micro Switch receives the following commands, they will be forwarded to all Group 2 nodes: Basic Set, Switch Binary Set, Scene Activation Set.
Association group 2 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |