DSC08 Smart Energy Illuminator
This describes the Z-Wave device DSC08, manufactured by AEON Labs with the thing type UID of aeon_dsc08_00_000
.
The DSC08 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
No device information is provided in the database. Consider updating the database to improve the documentation.
Channels
The following table summarises the channels available for the DSC08 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Dimmer | switch_dimmer | DimmableLight | Dimmer |
Sensor (power) | sensor_power | Energy | Number |
Electric meter (kWh) | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | Energy | Number |
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
Sensor (power)
Indicates the energy consumption (kWh).
The sensor_power
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (kWh)
Indicates the energy consumption (kWh).
The meter_kwh
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (watts)
Indicates the instantaneous power consumption.
The meter_watts
channel supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Device Configuration
The following table provides a summary of the 16 configuration parameters available in the DSC08. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Multilevel Sensor Report Content | |
2 | Make SES blink | |
80 | Automatic Notifications | Enables automatic notifications to associated devices whenever there is a state change |
90 | Enable Parameter 91 | Enables/disables parameter 91 and 92 below |
91 | Minimum change in wattage | The value here represents minimum change in wattage (in terms of wattage) for a REPORT to be sent. |
92 | Minimum change in wattage % | The value here represents minimum change in wattage percent (in terms of percentage) for a REPORT to be sent. |
100 | Set 100 to 103 to default | |
101 | Group 1 report | |
102 | Group 2 report | |
103 | Group 3 report | |
110 | Set 111 to 113 to default | |
111 | Interval group 1 | The time interval of sending Report group 1 |
112 | Interval group 1 | The time interval of sending Report group 2 |
113 | Interval group 1 | The time interval of sending Report group 3 |
254 | Device Tag | |
255 | Device Reset | |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 1: Multilevel Sensor Report Content
The following option values may be configured -:
Value | Description |
---|---|
0 | Power |
1 | Voltage |
The manufacturer defined default value is 0
(Power).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Make SES blink
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Parameter 80: Automatic Notifications
Enables automatic notifications to associated devices whenever there is a state change
The following option values may be configured -:
Value | Description |
---|---|
0 | Nothing |
1 | Hail |
2 | Basic CC Report |
The manufacturer defined default value is 0
(Nothing).
This parameter has the configuration ID config_80_1
and is of type INTEGER
.
Parameter 90: Enable Parameter 91
Enables/disables parameter 91 and 92 below
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_90_1
and is of type INTEGER
.
Parameter 91: Minimum change in wattage
The value here represents minimum change in wattage (in terms of wattage) for a REPORT to be sent.
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_91_2
and is of type INTEGER
.
Parameter 92: Minimum change in wattage %
The value here represents minimum change in wattage percent (in terms of percentage) for a REPORT to be sent.
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_92_1
and is of type INTEGER
.
Parameter 100: Set 100 to 103 to default
The following option values may be configured -:
Value | Description |
---|---|
0 | Reset |
The manufacturer defined default value is 0
(Reset).
This parameter has the configuration ID config_100_1
and is of type INTEGER
.
Parameter 101: Group 1 report
The following option values may be configured -:
Value | Description |
---|---|
2 | Multisensor Report |
4 | Meter Report (Watts) |
8 | Meter Report (kWh) |
The manufacturer defined default value is 8
(Meter Report (kWh)).
This parameter has the configuration ID config_101_4
and is of type INTEGER
.
Parameter 102: Group 2 report
The following option values may be configured -:
Value | Description |
---|---|
2 | Multisensor Report |
4 | Meter Report (Watts) |
8 | Meter Report (kWh) |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_102_4
and is of type INTEGER
.
Parameter 103: Group 3 report
The following option values may be configured -:
Value | Description |
---|---|
2 | Multisensor Report |
4 | Meter Report (Watts) |
8 | Meter Report (kWh) |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_103_4
and is of type INTEGER
.
Parameter 110: Set 111 to 113 to default
The following option values may be configured -:
Value | Description |
---|---|
0 | Reset |
The manufacturer defined default value is 0
(Reset).
This parameter has the configuration ID config_110_1
and is of type INTEGER
.
Parameter 111: Interval group 1
The time interval of sending Report group 1
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Parameter 112: Interval group 1
The time interval of sending Report group 2
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Parameter 113: Interval group 1
The time interval of sending Report group 3
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
Parameter 254: Device Tag
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_254_2
and is of type INTEGER
.
Parameter 255: Device Reset
This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Reset |
The manufacturer defined default value is 0
(Reset).
This parameter has the configuration ID config_255_1_wo
and is of type INTEGER
.
This is a write only parameter.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DSC08 supports 1 association group.
Group 1: Status Reports
Association group 1 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V3 | |
COMMAND_CLASS_METER_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |