# AVM FRITZ! Binding
|
|
|
|
The binding integrates the AHA ( [AVM Home Automation](http://avm.de/ratgeber/smart-home/) ) system.
|
|
|
|
## Supported Things
|
|
|
|
### FRITZ!Box
|
|
|
|
The well known FRITZ!Boxes are supported as bridge for accessing other AHA devices.
|
|
It is planned to support some channels directly at the bridge like call monitoring and others - but these things are under current development by now.
|
|
The Box has to run at least on firmware FRITZ!OS 6.00 and has to support the "Smart Home" service.
|
|
|
|
### FRITZ!DECT 200 / FRITZ!DECT 210
|
|
|
|
This switchable outlets [FRITZ!DECT 210](https://avm.de/produkte/fritzdect/fritzdect-210/) and [FRITZ!DECT 200](https://avm.de/produkte/fritzdect/fritzdect-200/) have to be connected to a FRITZ!Box by DECT protocol.
|
|
They support switching the outlet and reading the current power, current voltage, accumulated energy consumption and temperature.
|
|
**NOTE:** The `voltage` channel will be added to the thing during runtime - if the interface supports it (FRITZ!OS 7 or higher).
|
|
|
|
### FRITZ!DECT Repeater 100
|
|
|
|
This [DECT repeater](https://avm.de/produkte/fritzdect/fritzdect-repeater-100/) has to be connected to a FRITZ!Box by DECT protocol.
|
|
It only supports temperature readings.
|
|
|
|
### FRITZ!Powerline 546E
|
|
|
|
This [powerline adapter](http://avm.de/produkte/fritzpowerline/fritzpowerline-546e/) can be used via the bridge or in stand-alone mode.
|
|
It supports switching the outlet and reading the current power, current voltage and accumulated energy consumption.
|
|
This device does not contain a temperature sensor.
|
|
**NOTE:** The `voltage` channel will be added to the thing during runtime - if the interface supports it (FRITZ!OS 7 or higher).
|
|
|
|
### FRITZ!DECT 301 / FRITZ!DECT 300 / Comet DECT
|
|
|
|
These devices [FRITZ!DECT 301](https://avm.de/produkte/fritzdect/fritzdect-301/), FRITZ!DECT 300 and [Comet DECT](https://www.eurotronic.org/produkte/comet-dect.html) ( [EUROtronic Technology GmbH](https://www.eurotronic.org) ) are used to regulate radiators via DECT protocol.
|
|
The FRITZ!Box can handle up to twelve heating thermostats.
|
|
The binding provides channels for reading and setting the temperature.
|
|
Additionally you can check the eco temperature, the comfort temperature and the battery level of the device.
|
|
The FRITZ!Box has to run at least on firmware FRITZ!OS 6.35.
|
|
**NOTE:** The `battery_level` channel will be added to the thing during runtime - if the interface supports it (FRITZ!OS 7 or higher).
|
|
|
|
### DECT-ULE / HAN-FUN devices
|
|
|
|
The following sensors have been successfully tested using FRITZ!OS 7 for FRITZ!Box 7490 / 7590:
|
|
|
|
- [SmartHome Tür-/Fensterkontakt (optisch)](https://www.smarthome.de/geraete/eurotronic-smarthome-tuer-fensterkontakt-optisch) - an optical door/window contact
|
|
- SmartHome Tür-/Fensterkontakt (magnetisch) - a magnetic door/window contact
|
|
- [SmartHome Bewegungsmelder](https://www.smarthome.de/geraete/telekom-smarthome-bewegungsmelder-innen) - a motion sensor
|
|
- [SmartHome Rauchmelder](https://www.smarthome.de/geraete/smarthome-rauchmelder-weiss) - a smoke detector
|
|
- [SmartHome Wandtaster](https://www.smarthome.de/geraete/telekom-smarthome-wandtaster) - a switch with two buttons
|
|
|
|
The use of other Sensors should be possible, if these are compatible with DECT-ULE / HAN-FUN standards.
|
|
|
|
The FRITZ!Box has to run at least on firmware FRITZ!OS 7.
|
|
|
|
### FRITZ! groups
|
|
|
|
The FRITZ!OS supports two different types of groups.
|
|
On the one hand there are groups for heating thermostats on the other hand there are groups for switchable outlets and power meters.
|
|
The first one provides the same channels like the [FRITZ!DECT 301 / FRITZ!DECT 300 / Comet DECT](https://www.openhab.org/addons/bindings/avmfritz/#fritz-dect-301-fritz-dect-300-comet-dect) devices.
|
|
The later one provides the same channels like the [FRITZ!DECT 200 / FRITZ!DECT 210](https://www.openhab.org/addons/bindings/avmfritz/#fritz-dect-200-fritz-dect-210) / [FRITZ!Powerline 546E](https://www.openhab.org/addons/bindings/avmfritz/#fritz-powerline-546e) devices.
|
|
The FRITZ!Box has to run at least on firmware FRITZ!OS 6.69.
|
|
|
|
## Discovery
|
|
|
|
The FRITZ!Box and the powerline adapter are discovered through UPnP in the local network.
|
|
Auto-discovery is enabled by default.
|
|
When added as things, a username/password has eventually to be set depending on your Box/Powerline security configuration.
|
|
The credentials given in the settings must have HomeAuto permissions.
|
|
To disable it, you can add the following line to `<openHAB-conf>/services/runtime.cfg`:
|
|
|
|
```
|
|
discovery.avmfritz:background=false
|
|
```
|
|
|
|
If correct credentials are set in the bridge configuration, connected AHA devices are discovered automatically (may last up to 3 minutes).
|
|
|
|
## Thing Configuration
|
|
|
|
### FRITZ!Box
|
|
|
|
- ipAddress (mandatory), default "fritz.box"
|
|
- protocol (optional, http or https), default "http"
|
|
- port (optional, 0 to 65335), no default (derived from protocol: 80 or 443)
|
|
- password (optional), no default (depends on FRITZ!Box security configuration)
|
|
- user (optional), no default (depends on FRITZ!Box security configuration)
|
|
- pollingInterval (optional, 5 to 60), default 15 (in seconds)
|
|
- asyncTimeout (optional, 1000 to 60000), default 10000 (in millis)
|
|
- syncTimeout (optional, 500 to 15000), default 2000 (in millis)
|
|
|
|
### FRITZ!Powerline 546E
|
|
|
|
- ipAddress (mandatory), default "fritz.powerline"
|
|
- protocol (optional, http or https), default "http"
|
|
- port (optional, 0 to 65335), no default (derived from protocol: 80 or 443)
|
|
- password (optional), no default (depends on FRITZ!Powerline security configuration)
|
|
- pollingInterval (optional, 5 to 60), default 15 (in seconds)
|
|
- asyncTimeout (optional, 1000 to 60000), default 10000 (in millis)
|
|
- syncTimeout (optional, 500 to 15000), default 2000 (in millis)
|
|
|
|
### AHA things connected to FRITZ!Box bridge
|
|
|
|
- AIN (mandatory), no default (AIN number of device)
|
|
|
|
## Supported Channels
|
|
|
|
| Channel Type ID | Item Type | Description | Available on thing |
|
|
|-----------------|--------------------------|--------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------|
|
|
| mode | String | States the mode of the device (MANUAL/AUTOMATIC/VACATION) | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E, FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
|
| locked | Contact | Device is locked for switching over external sources (OPEN/CLOSE) | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E, FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
|
| device_locked | Contact | Device is locked for switching manually (OPEN/CLOSE) - FRITZ!OS 6.90 | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E, FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
|
| temperature | Number:Temperature | Current measured temperature | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!DECT Repeater 100, FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
|
| energy | Number:Energy | Accumulated energy consumption | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
|
| power | Number:Power | Current power consumption | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
|
| voltage | Number:ElectricPotential | Current voltage - FRITZ!OS 7 | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
|
| outlet | Switch | Switchable outlet (ON/OFF) | FRITZ!DECT 210, FRITZ!DECT 200, FRITZ!Powerline 546E |
|
|
| actual_temp | Number:Temperature | Current temperature of heating thermostat | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
|
| set_temp | Number:Temperature | Set Temperature of heating thermostat | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
|
| eco_temp | Number:Temperature | Eco Temperature of heating thermostat | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
|
| comfort_temp | Number:Temperature | Comfort Temperature of heating thermostat | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
|
| radiator_mode | String | Mode of heating thermostat (ON/OFF/COMFORT/ECO/BOOST/WINDOW_OPEN) | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
|
| next_change | DateTime | Next change of the Set Temperature if scheduler is activated in the FRITZ!Box settings - FRITZ!OS 6.80 | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
|
| next_temp | Number:Temperature | Next Set Temperature if scheduler is activated in the FRITZ!Box settings - FRITZ!OS 6.80 | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
|
| battery_level | Number | Battery level (in %) - FRITZ!OS 7 | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
|
| battery_low | Switch | Battery level low (ON/OFF) - FRITZ!OS 6.80 | FRITZ!DECT 301, FRITZ!DECT 300, Comet DECT |
|
|
| contact_state | Contact | Contact state information (OPEN/CLOSED). | HAN-FUN contact (e.g. SmartHome Tür-/Fensterkontakt or SmartHome Bewegungsmelder)- FRITZ!OS 7 |
|
|
| last_change | DateTime | States the last time the button was pressed. | HAN-FUN switch (e.g. SmartHome Wandtaster) - FRITZ!OS 7 |
|
|
|
|
### Triggers
|
|
|
|
| Channel Type ID | Item Type | Description | Available on thing |
|
|
|-----------------|-----------|--------------------------------------|---------------------------------------------------------|
|
|
| press | Trigger | Dispatched when a button is pressed. | HAN-FUN switch (e.g. SmartHome Wandtaster) - FRITZ!OS 7 |
|
|
|
|
## Full Example
|
|
|
|
demo.things:
|
|
|
|
```java
|
|
Bridge avmfritz:fritzbox:1 "FRITZ!Box" [ ipAddress="192.168.x.x", password="xxx", user="xxx" ] {
|
|
Thing FRITZ_DECT_200 xxxxxxxxxxxx "FRITZ!DECT 200 #1" [ ain="xxxxxxxxxxxx" ]
|
|
Thing FRITZ_Powerline_546E yy_yy_yy_yy_yy_yy "FRITZ!Powerline 546E #2" [ ain="yy:yy:yy:yy:yy:yy" ]
|
|
Thing Comet_DECT aaaaaabbbbbb "Comet DECT #3" [ ain="aaaaaabbbbbb" ]
|
|
Thing HAN_FUN_CONTACT zzzzzzzzzzzz_1 "HAN-FUN Contact #4" [ ain="zzzzzzzzzzzz-1" ]
|
|
Thing HAN_FUN_SWITCH zzzzzzzzzzzz_2 "HAN-FUN Switch #5" [ ain=zzzzzzzzzzzz-2" ]
|
|
Thing FRITZ_GROUP_HEATING AA_AA_AA_900 "Heating group" [ ain="AA:AA:AA-900" ]
|
|
Thing FRITZ_GROUP_SWITCH BB_BB_BB_900 "Switch group" [ ain="BB:BB:BB-900" ]
|
|
}
|
|
```
|
|
|
|
demo.items:
|
|
|
|
```java
|
|
Switch Outlet1 "Switchable outlet" { channel="avmfritz:FRITZ_DECT_200:1:xxxxxxxxxxxx:outlet" }
|
|
Number:Temperature Temperature1 "Current measured temperature [%.1f %unit%]" { channel="avmfritz:FRITZ_DECT_200:1:xxxxxxxxxxxx:temperature" }
|
|
Number:Energy Energy1 "Accumulated energy consumption [%.3f kWh]" { channel="avmfritz:FRITZ_DECT_200:1:xxxxxxxxxxxx:energy" }
|
|
Number:Power Power1 "Current power consumption [%.2f %unit%]" { channel="avmfritz:FRITZ_DECT_200:1:xxxxxxxxxxxx:power" }
|
|
Number:ElectricPotential Voltage1 "Current voltage [%.1f %unit%]" { channel="avmfritz:FRITZ_DECT_200:1:xxxxxxxxxxxx:voltage" }
|
|
|
|
Switch Outlet2 "Switchable outlet" { channel="avmfritz:FRITZ_Powerline_546E:1:yy_yy_yy_yy_yy_yy:outlet" }
|
|
|
|
Number:Temperature COMETDECTTemperature "Current measured temperature [%.1f %unit%]" { channel="avmfritz:Comet_DECT:1:aaaaaabbbbbb:actual_temp" }
|
|
Number:Temperature COMETDECTSetTemperature "Thermostat temperature set point [%.1f %unit%]" { channel="avmfritz:Comet_DECT:1:aaaaaabbbbbb:set_temp" }
|
|
String COMETDECTRadiatorMode "Radiator mode [%s]" { channel="avmfritz:Comet_DECT:1:aaaaaabbbbbb:radiator_mode" }
|
|
Number COMETDECTBattery "Battery level" { channel="avmfritz:Comet_DECT:1:aaaaaabbbbbb:battery_level" }
|
|
Switch COMETDECTBatteryLow "Battery low" { channel="avmfritz:Comet_DECT:1:aaaaaabbbbbb:battery_low" }
|
|
|
|
Contact HANFUNContactState "Status [%s]" { channel="avmfritz:HAN_FUN_CONTACT:1:zzzzzzzzzzzz_1:contact_state" }
|
|
|
|
DateTime HANFUNSwitchLastChanged "Last change" { channel="avmfritz:HAN_FUN_SWITCH:1:zzzzzzzzzzzz_2:last_change" }
|
|
|
|
Number:Temperature FRITZ_GROUP_HEATINGSetTemperature "Group temperature set point [%.1f %unit%]" { channel="avmfritz:FRITZ_GROUP_HEATING:1:AA_AA_AA_900:set_temp" }
|
|
|
|
Switch Outlet3 "Group switch" { channel="avmfritz:FRITZ_GROUP_SWITCH:1:BB_BB_BB_900:outlet" }
|
|
```
|
|
|
|
demo.sitemap:
|
|
|
|
```java
|
|
sitemap demo label="Main Menu" {
|
|
|
|
Frame label="FRITZ!DECT 200 switchable outlet" {
|
|
Switch item=Outlet1 icon="poweroutlet"
|
|
Text item=Temperature1 icon="temperature"
|
|
Text item=Energy1 icon="energy"
|
|
Text item=Power1 icon="energy"
|
|
Text item=Voltage1 icon="energy"
|
|
}
|
|
|
|
Frame label="FRITZ!Powerline 546E switchable outlet" {
|
|
Switch item=Outlet2 icon="poweroutlet"
|
|
}
|
|
|
|
Frame label="Comet DECT heating thermostat" {
|
|
Text item=COMETDECTTemperature icon="temperature"
|
|
Setpoint item=COMETDECTSetTemperature minValue=8.0 maxValue=28.0 step=0.5 icon="temperature"
|
|
Selection item=COMETDECTRadiatorMode mappings=["ON"="ON", "OFF"="OFF", "COMFORT"="COMFORT", "ECO"="ECO", "BOOST"="BOOST"] icon="heating"
|
|
Text item=COMETDECTBattery icon="battery"
|
|
Switch item=COMETDECTBatteryLow icon="lowbattery"
|
|
}
|
|
|
|
Frame label="HAN-FUN Contact" {
|
|
Text item=HANFUNContactState
|
|
}
|
|
|
|
Frame label="HAN-FUN Switch" {
|
|
Text item=HANFUNSwitchLastChanged
|
|
}
|
|
}
|
|
```
|
|
|
|
demo.rule:
|
|
|
|
```java
|
|
rule "HAN-FUN Button pressed"
|
|
when
|
|
Channel "avmfritz:HAN_FUN_SWITCH:1:zzzzzzzzzzzz_2:press" triggered
|
|
then
|
|
logInfo("demo", "Button pressed")
|
|
end
|
|
```
|