78 lines
2.3 KiB
Markdown
78 lines
2.3 KiB
Markdown
---
|
|
description: "Telegraf plugin for collecting metrics from Temperature"
|
|
menu:
|
|
telegraf_v1_ref:
|
|
parent: input_plugins_reference
|
|
name: Temperature
|
|
identifier: input-temp
|
|
tags: [Temperature, "input-plugins", "configuration", "hardware", "system"]
|
|
introduced: "v1.8.0"
|
|
os_support: "linux, macos, windows"
|
|
related:
|
|
- /telegraf/v1/configure_plugins/
|
|
- https://github.com/influxdata/telegraf/tree/v1.36.1/plugins/inputs/temp/README.md, Temperature Plugin Source
|
|
---
|
|
|
|
# Temperature Input Plugin
|
|
|
|
This plugin gathers metrics on system temperatures.
|
|
|
|
**Introduced in:** Telegraf v1.8.0
|
|
**Tags:** hardware, system
|
|
**OS support:** linux, macos, windows
|
|
|
|
## Global configuration options <!-- @/docs/includes/plugin_config.md -->
|
|
|
|
In addition to the plugin-specific configuration settings, plugins support
|
|
additional global and plugin configuration settings. These settings are used to
|
|
modify metrics, tags, and field or create aliases and configure ordering, etc.
|
|
See the [CONFIGURATION.md](/telegraf/v1/configuration/#plugins) for more details.
|
|
|
|
[CONFIGURATION.md]: ../../../docs/CONFIGURATION.md#plugins
|
|
|
|
## Configuration
|
|
|
|
```toml @sample.conf
|
|
# Read metrics about temperature
|
|
[[inputs.temp]]
|
|
## Desired output format (Linux only)
|
|
## Available values are
|
|
## v1 -- use pre-v1.22.4 sensor naming, e.g. coretemp_core0_input
|
|
## v2 -- use v1.22.4+ sensor naming, e.g. coretemp_core_0_input
|
|
# metric_format = "v2"
|
|
|
|
## Add device tag to distinguish devices with the same name (Linux only)
|
|
# add_device_tag = false
|
|
```
|
|
|
|
## Troubleshooting
|
|
|
|
On **Windows**, the plugin uses a WMI call that is can be replicated with the
|
|
following command:
|
|
|
|
```shell
|
|
wmic /namespace:\\root\wmi PATH MSAcpi_ThermalZoneTemperature
|
|
```
|
|
|
|
If the result is "Not Supported" you may be running in a virtualized environment
|
|
and not a physical machine. Additionally, if you still get this result your
|
|
motherboard or system may not support querying these values. Finally, you may
|
|
be required to run as admin to get the values.
|
|
|
|
## Metrics
|
|
|
|
- temp
|
|
- tags:
|
|
- sensor
|
|
- fields:
|
|
- temp (float, celcius)
|
|
|
|
## Example Output
|
|
|
|
```text
|
|
temp,sensor=coretemp_physicalid0_crit temp=100 1531298763000000000
|
|
temp,sensor=coretemp_physicalid0_critalarm temp=0 1531298763000000000
|
|
temp,sensor=coretemp_physicalid0_input temp=100 1531298763000000000
|
|
temp,sensor=coretemp_physicalid0_max temp=100 1531298763000000000
|
|
```
|