description: "Telegraf plugin for sending metrics to Apache IoTDB"
|
|
menu:
|
|
telegraf_v1_ref:
|
|
parent: output_plugins_reference
|
|
name: Apache IoTDB
|
|
identifier: output-iotdb
|
|
tags: [Apache IoTDB, "output-plugins", "configuration"]
|
|
related:
|
|
- /telegraf/v1/configure_plugins/
|
|
---
|
|
|
|
# Apache IoTDB Output Plugin
|
|
|
|
This plugin writes metrics to an [Apache IoTDB](https://iotdb.apache.org) instance, a database
|
|
for the Internet of Things, supporting session connection and data insertion.
|
|
|
|
**introduces in:** Telegraf v1.24.0
|
|
**tags:** datastore
|
|
**supported OS:** all
|
|
|
|
[iotdb]: https://iotdb.apache.org
|
|
|
|
## Getting started
|
|
|
|
Before using this plugin, please configure the IP address, port number,
|
|
user name, password and other information of the database server,
|
|
as well as some data type conversion, time unit and other configurations.
|
|
|
|
Please see the configuration section
|
|
|
|
IoTDB uses a tree model for metadata while Telegraf uses a tag model
|
|
(see [InfluxDB-Protocol Adapter](https://iotdb.apache.org/UserGuide/Master/API/InfluxDB-Protocol.html)).
|
|
There are two available options of converting tags, which are specified by
|
|
setting `convert_tags_to`:
|
|
|
|
- `fields`. Treat Tags as measurements. For each Key:Value in Tag,
|
|
convert them into Measurement, Value, DataType, which are supported in IoTDB.
|
|
- `device_id`, default option. Treat Tags as part of device id. Tags
|
|
constitute a subtree of `Name`.
|
|
|
|
For example, there is a metric:
|
|
|
|
```markdown
|
|
Name="root.sg.device", Tags={tag1="private", tag2="working"}, Fields={s1=100, s2="hello"}
|
|
```
|
|
|
|
- `fields`, result: `root.sg.device, s1=100, s2="hello", tag1="private", tag2="working"`
|
|
- `device_id`, result: `root.sg.device.private.working, s1=100, s2="hello"`
|
|
|
|
[InfluxDB-Protocol Adapter]: https://iotdb.apache.org/UserGuide/Master/API/InfluxDB-Protocol.html
|
|
|
|
## Global configuration options <!-- @/docs/includes/plugin_config.md -->
|
|
|
|
In addition to the plugin-specific configuration settings, plugins support
|
|
additional global and plugin configuration settings. These settings are used to
|
|
modify metrics, tags, and field or create aliases and configure ordering, etc.
|
|
See the [CONFIGURATION.md](/telegraf/v1/configuration/#plugins) for more details.
|
|
|
|
[CONFIGURATION.md]: ../../../docs/CONFIGURATION.md#plugins
|
|
|
|
## Secret-store support
|
|
|
|
This plugin supports secrets from secret-stores for the `username` and
|
|
`password` option.
|
|
See the [secret-store documentation](/telegraf/v1/configuration/#secret-store-secrets) for more details on how
|
|
to use them.
|
|
|
|
[SECRETSTORE]: ../../../docs/CONFIGURATION.md#secret-store-secrets
|
|
|
|
## Configuration
|
|
|
|
```toml @sample.conf
|
|
# Save metrics to an IoTDB Database
|
|
[[outputs.iotdb]]
|
|
## Configuration of IoTDB server connection
|
|
host = "127.0.0.1"
|
|
# port = "6667"
|
|
|
|
## Configuration of authentication
|
|
# user = "root"
|
|
# password = "root"
|
|
|
|
## Timeout to open a new session.
|
|
## A value of zero means no timeout.
|
|
# timeout = "5s"
|
|
|
|
## Configuration of type conversion for 64-bit unsigned int
|
|
## IoTDB currently DOES NOT support unsigned integers (version 13.x).
|
|
## 32-bit unsigned integers are safely converted into 64-bit signed integers by the plugin,
|
|
## however, this is not true for 64-bit values in general as overflows may occur.
|
|
## The following setting allows to specify the handling of 64-bit unsigned integers.
|
|
## Available values are:
|
|
## - "int64" -- convert to 64-bit signed integers and accept overflows
|
|
## - "int64_clip" -- convert to 64-bit signed integers and clip the values on overflow to 9,223,372,036,854,775,807
|
|
## - "text" -- convert to the string representation of the value
|
|
# uint64_conversion = "int64_clip"
|
|
|
|
## Configuration of TimeStamp
|
|
## TimeStamp is always saved in 64bits int. timestamp_precision specifies the unit of timestamp.
|
|
## Available value:
|
|
## "second", "millisecond", "microsecond", "nanosecond"(default)
|
|
# timestamp_precision = "nanosecond"
|
|
|
|
## Handling of tags
|
|
## Tags are not fully supported by IoTDB.
|
|
## A guide with suggestions on how to handle tags can be found here:
|
|
## https://iotdb.apache.org/UserGuide/Master/API/InfluxDB-Protocol.html
|
|
##
|
|
## Available values are:
|
|
## - "fields" -- convert tags to fields in the measurement
|
|
## - "device_id" -- attach tags to the device ID
|
|
##
|
|
## For Example, a metric named "root.sg.device" with the tags `tag1: "private"` and `tag2: "working"` and
|
|
## fields `s1: 100` and `s2: "hello"` will result in the following representations in IoTDB
|
|
## - "fields" -- root.sg.device, s1=100, s2="hello", tag1="private", tag2="working"
|
|
## - "device_id" -- root.sg.device.private.working, s1=100, s2="hello"
|
|
# convert_tags_to = "device_id"
|
|
|
|
## Handling of unsupported characters
|
|
## Some characters in different versions of IoTDB are not supported in path name
|
|
## A guide with suggetions on valid paths can be found here:
|
|
## for iotdb 0.13.x -> https://iotdb.apache.org/UserGuide/V0.13.x/Reference/Syntax-Conventions.html#identifiers
|
|
## for iotdb 1.x.x and above -> https://iotdb.apache.org/UserGuide/V1.3.x/User-Manual/Syntax-Rule.html#identifier
|
|
##
|
|
## Available values are:
|
|
## - "1.0", "1.1", "1.2", "1.3" -- use backticks to enclose tags with forbidden characters
|
|
## such as @$#:[]{}() and space
|
|
## - "0.13" -- use backticks to enclose tags with forbidden characters
|
|
## such as space
|
|
## Keep this section commented if you don't want to sanitize the path
|
|
# sanitize_tag = "1.3"
|
|
```
|