title: Bosch Alarm
|
||
description: Integrate Bosch Alarms.
|
||
ha_category:
|
||
- Alarm
|
||
- Binary Sensor
|
||
- Sensor
|
||
- Switch
|
||
ha_release: 2025.4
|
||
ha_iot_class: Local Push
|
||
ha_config_flow: true
|
||
ha_codeowners:
|
||
- '@mag1024'
|
||
- '@sanjay900'
|
||
ha_domain: bosch_alarm
|
||
ha_platforms:
|
||
- alarm_control_panel
|
||
- binary_sensor
|
||
- diagnostics
|
||
- sensor
|
||
- switch
|
||
ha_integration_type: device
|
||
ha_quality_scale: platinum
|
||
ha_dhcp: true
|
||
---
|
||
|
||
The **Bosch Alarm Panel** {% term integration %} allows you to connect your [Bosch Alarm Panel](https://www.boschsecurity.com) to Home Assistant to control and monitor your Bosch Alarm Panel.
|
||
|
||
{% include integrations/config_flow.md %}
|
||
|
||
{% configuration_basic %}
|
||
Host:
|
||
description: "The IP address of your panel. You can find it in your router, or within A-Link Plus / RPS."
|
||
Port:
|
||
description: "The port used by your panel. This is usually 7700 unless it was changed when the panel was configured."
|
||
Password:
|
||
description: "The automation code set up for your panel. This can be found within A-Link Plus or RPS. Used by the AMAX, B and G series panels."
|
||
User code:
|
||
description: "The user code for the user that this integration will communicate with the panel with. This is usually the code you would use when arming or disarming the panel via a code pad. Used by the Solution series panels."
|
||
Installer code:
|
||
description: "The installer code for your panel. This can be found within A-Link Plus. Used by the AMAX series panels."
|
||
|
||
{% endconfiguration_basic %}
|
||
|
||
{% important %}
|
||
Since the _Mode 2_ automation user has "superuser" privileges, it bypasses the regularly configured alarm pin: you will _not_ be prompted for a _User_ code when arming/disarming through the integration.
|
||
{% endimportant %}
|
||
|
||
## Supported devices
|
||
|
||
- _Solution 2000/3000/4000_
|
||
- B Series: _B3512/B4512/B5512/B6512_
|
||
- G Series: _B8512G/B9512G_
|
||
- _AMAX 2100/3000/4000_
|
||
- _D7412GV4/D9412GV4_ [^1]
|
||
|
||
[^1]: Firmware 2.0+
|
||
|
||
## Provided entities
|
||
|
||
The following {% term entities %} are provided:
|
||
|
||
- [Alarm Control Panel](#alarm-control-panel)
|
||
- [Binary Sensor](#binary-sensor)
|
||
- [Sensor](#sensor)
|
||
- [Switch](#switch)
|
||
|
||
### Alarm Control Panel
|
||
|
||
This integration adds an Alarm Control Panel device for each configured area, with the ability to issue arm/disarm commands.
|
||
This entity reports state (_disarmed_, _armed_away_, etc.).
|
||
|
||
### Binary Sensor
|
||
|
||
A binary sensor is added for each point configured on your alarm.
|
||
|
||
Two binary sensors are added for each area to indicate whether it can be armed away or armed home.
|
||
|
||
### Sensor
|
||
|
||
A sensor is provided per area that lists how many points are currently in a faulted state.
|
||
|
||
A sensor is provided for each of the following alarm types that displays the health of that alarm
|
||
|
||
- Fire
|
||
- Gas
|
||
- Burglary
|
||
|
||
The state for the sensor can be one of the following:
|
||
|
||
- No issues
|
||
- Trouble
|
||
|
||
These signals indicate a malfunction or failure within the system. These signals often point to something that, if left unresolved, could lead to a complete system failure. For example, a broken wire or a failed smoke detector could trigger a trouble signal. These signals generally require prompt action to ensure the system continues to work as intended.
|
||
|
||
- Supervisory
|
||
|
||
These signals relate to system components that require attention but are not in immediate danger of failing. They are typically non-urgent and indicate that something within the system needs maintenance or is functioning suboptimally. These signals might include a closed valve or a fire extinguisher that’s out of service.
|
||
|
||
- Alarm
|
||
|
||
The alarm is currently triggered.
|
||
|
||
### Switch
|
||
|
||
A switch is added for each output configured on the panel. Note that for some panels, only outputs with the type set to **remote output** can be controlled via _Mode 2_ API.
|
||
|
||
Three switches are added per door, which allow for locking, securing, or momentarily unlocking the door.
|
||
|
||
## Actions
|
||
|
||
The integration provides the following actions.
|
||
|
||
### Action: Set panel date and time
|
||
|
||
The `bosch_alarm.set_date_time` action is used to update the date and time on the panel.
|
||
|
||
- **Data attribute**: `config_entry_id`
|
||
- **Description**: The ID of the config entry of the panel being updated.
|
||
- **Optional**: No
|
||
|
||
- **Data attribute**: `datetime`
|
||
- **Description**: The date and time to set. Defaults to the current date and time if it is not set.
|
||
- **Optional**: Yes
|
||
|
||
{% raw %}
|
||
|
||
```yaml
|
||
# Example: Update the panel’s date and time
|
||
service: bosch_alarm.set_date_time
|
||
data:
|
||
config_entry_id: "YOUR_CONFIG_ENTRY_ID"
|
||
datetime: "2025-05-01T12:00:00"
|
||
```
|
||
{% endraw %}
|
||
|
||
## Authentication
|
||
|
||
The primary means of authentication for the _Mode 2_ API is the _Automation_ passcode. It needs to be at least 10 characters long, and it is different from the _User_ code -- a shorter numeric pin used to arm/disarm the panel.
|
||
The integration will prompt for the required passcodes, which depend on the panel type.
|
||
|
||
| Panel | Code |
|
||
| -------- | ---------- |
|
||
| Solution | User [^2] |
|
||
| B Series | Automation |
|
||
| G Series | Automation |
|
||
| AMAX | Both |
|
||
|
||
[^2]: The user needs to have the "master code functions" authority if you wish to interact with history events.
|
||
|
||
{% important %}
|
||
Since the _Mode 2_ automation user has "superuser" privileges, it bypasses the regularly configured alarm pin: you will _not_ be prompted for a _User_ code when arming/disarming through the integration.
|
||
{% endimportant %}
|
||
|
||
## Data updates
|
||
|
||
The **Bosch Alarm** {% term integration %} fetches data from the device every 30 seconds.
|
||
Newer devices and firmware revisions have the possibility to push data instead of needing to rely on {% term polling %}.
|
||
At startup, the integration checks whether your panel supports push data updates and falls back to {% term polling %} if not.
|
||
|
||
## Examples
|
||
|
||
### Turning on lights when walking into a room
|
||
|
||
{% raw %}
|
||
|
||
```yaml
|
||
automation:
|
||
- alias: "Turn on light when walking into room"
|
||
triggers:
|
||
- platform: state
|
||
entity_id:
|
||
- binary_sensor.bosch_solution_3000_bedroom
|
||
to: "on"
|
||
actions:
|
||
- action: light.turn_on
|
||
target:
|
||
entity_id: light.bedroom_light
|
||
|
||
|
||
```
|
||
|
||
{% endraw %}
|
||
|
||
## Reconfiguration
|
||
|
||
This integration supports reconfiguration, so it is possible to change the configuration such as the IP Address after it is configured.
|
||
|
||
## Troubleshooting
|
||
|
||
### Issues with Bosch Solution 2000/3000/4000 panels
|
||
|
||
We have found that some panels end up with a configuration on them that is incompatible with the integration.
|
||
When this happens, you will get a connection error when attempting to communicate with the panel, even if the credentials are correct.
|
||
If you continue to have connection errors even after rebooting your panel, then you have an issue with your configuration.
|
||
The easiest way to solve this is to follow the full reset and restore procedure outline below.
|
||
|
||
#### Resetting the configuration and restoring the integration
|
||
|
||
1. Update firmware (Recommended).
|
||
1. Download and install the latest firmware for the control panel and IP module from the Bosch Security website.
|
||
2. Back up the existing configuration.
|
||
1. Connect to the panel via A-Link Plus.
|
||
2. Perform an upload of the panel configuration.
|
||
3. Save the configuration to your computer.
|
||
3. Default the control panel.
|
||
1. Press the default/reset button on the panel.
|
||
2. Use installer code 1234.
|
||
3. Set:
|
||
1. Location 0081 = 3 (Enables IP module mode)
|
||
2. Location 4456 = 4 (Enables RSC+ communication)
|
||
4. Set date and time using master code `25806#`.
|
||
4. Initial Home Assistant test.
|
||
1. Wait 2 to 5 minutes after resetting the panel.
|
||
2. Set up the integration on the panel using its IP address.
|
||
3. Home Assistant should connect using default configuration and show panel status.
|
||
5. Restore your original configuration.
|
||
1. Reconnect to the panel using A-Link Plus.
|
||
2. Modify zones, outputs, and user codes to match the original setup.
|
||
3. Save and download the updated config to the panel.
|
||
4. Wait 2 to 5 minutes.
|
||
6. Reconnect to Home Assistant.
|
||
1. Open Home Assistant.
|
||
2. The integration should now detect the updated configuration.
|
||
3. All relevant entities (zones, partitions, outputs) should appear automatically.
|
||
|
||
#### Restarting a panels network stack
|
||
|
||
We have found that the Solution panels have a bug where they can get into a state where the network module stops letting us use the _Mode 2_ API.
|
||
If your configuration information is correct, but you are still unable to connect to your panel, then you are likely encountering this bug.
|
||
This can be resolved by restarting the network modules, which can be done with the following steps.
|
||
|
||
##### Resetting network module 1
|
||
|
||
Using the codepad, enter your master code, followed by the `[9][4][1]` and `[#]` keys.
|
||
|
||
##### Resetting network module 2
|
||
|
||
Using the codepad, enter your master code, followed by the `[9][4][2]` and `[#]` keys.
|
||
|
||
### Issues with the Bosch B/G Series (B3512/B4512/B5512/B8512/B9512)
|
||
|
||
The following procedure can be used to configure the panel correctly so that it will work with the integration.
|
||
|
||
#### Panel configuration procedure
|
||
|
||
1. Update Firmware (Recommended).
|
||
1. Use RPS to update the control panel and B426 (IP module if used) to the latest firmware.
|
||
2. Download firmware from the Bosch Security website.
|
||
2. Set IP Address.
|
||
1. Configure the panel’s IP settings using RPS or via the codepad.
|
||
2. Use DHCP for initial setup (optional), or assign a static IP.
|
||
3. Configure the automation device.
|
||
1. In RPS:
|
||
1. Set **Automation Device** to **Mode 2** (Bosch Standard Protocol).
|
||
2. Set your automation passcode (used for Home Assistant authentication).
|
||
4. Wait for changes to apply.
|
||
1. Wait 2 to 5 minutes for the panel to reboot and apply settings.
|
||
5. Connect to Home Assistant.
|
||
1. Set up the integration using the panel’s IP address.
|
||
2. Enter the automation passcode in the Home Assistant configuration.
|
||
3. Home Assistant should connect and display panel status, zones, and partitions.
|
||
|
||
#### TLS issues
|
||
|
||
Some older firmwares for these panels use outdated certificates that are no longer trusted by Home Assistant. If you have issues connecting and see a TLS error in your logs, update the firmware on your panel.
|
||
|
||
## Known limitations
|
||
|
||
- The integration does not allow you to configure the panel; you can instead do this via the panel's configuration utility.
|
||
- Some older firmware versions for the Solution / AMAX series panels only support a single connection at a time. If you try to have a cloud connection and use the integration on these panels simultaneously, the panel's network stack can lock up, and the integration will stop working.
|
||
|
||
## Removing the integration
|
||
|
||
This integration follows standard integration removal. No extra steps are required.
|
||
|
||
{% include integrations/remove_device_service.md %}
|