79 lines
2.4 KiB
Markdown
79 lines
2.4 KiB
Markdown
---
|
|
title: Concord232
|
|
description: Instructions on how to integrate Interlogix/GE Concord4 into Home Assistant.
|
|
ha_category:
|
|
- Alarm
|
|
- Binary Sensor
|
|
ha_iot_class: Local Polling
|
|
ha_release: 0.31
|
|
ha_domain: concord232
|
|
ha_platforms:
|
|
- alarm_control_panel
|
|
- binary_sensor
|
|
ha_integration_type: integration
|
|
---
|
|
|
|
The `concord232` platform provides integration with GE, Interlogix (and other brands) alarm panels that support the RS-232 Automation Control Panel interface module (or have it built in). Supported panels include Concord 4.
|
|
|
|
To use this platform, you will need to have the external concord232 client and server installed. The server must be running on the device which is connected to the automation module's serial port. The client must be installed on the machine running Home Assistant. These may often be the same machine, but do not have to be. For additional details in setting up and testing the client and server, see <https://github.com/JasonCarter80/concord232>.
|
|
|
|
There is currently support for the following device types within Home Assistant:
|
|
|
|
- [Alarm](#alarm-control-panel)
|
|
- [Binary Sensor](#binary-sensor)
|
|
|
|
## Alarm Control Panel
|
|
|
|
To enable the alarm control panel platform, add the following lines to your `configuration.yaml`:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
alarm_control_panel:
|
|
- platform: concord232
|
|
```
|
|
|
|
{% configuration %}
|
|
host:
|
|
description: The host where the concord232 server process is running.
|
|
required: false
|
|
type: string
|
|
default: localhost
|
|
port:
|
|
description: The port where the Alarm panel is listening.
|
|
required: false
|
|
type: integer
|
|
default: 5007
|
|
code:
|
|
description: If defined, specifies a code to enable or disable the alarm in the frontend.
|
|
required: false
|
|
type: string
|
|
mode:
|
|
description: audible/silent if defined, specifies whether Alarm Panel should be audible or silent when armed in Home Mode.
|
|
required: false
|
|
type: string
|
|
default: audible
|
|
{% endconfiguration %}
|
|
|
|
## Binary Sensor
|
|
|
|
To enable the binary sensor platform, add the following lines to your `configuration.yaml`:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
binary_sensor:
|
|
- platform: concord232
|
|
```
|
|
|
|
{% configuration %}
|
|
host:
|
|
description: The host where the concord232 server process is running.
|
|
required: false
|
|
type: string
|
|
default: localhost
|
|
port:
|
|
description: The port where the Alarm panel is listening.
|
|
required: false
|
|
type: integer
|
|
default: 5007
|
|
{% endconfiguration %}
|