Instead of user defined symbols in assembly files or C files,
use linker scripts to add heap and stack - this is inconsistent
with ARM std linker scripts
--legacyalign, --no_legacyalign are deprecated from ARMC6 compiler, in order to
remove deprecated flags all linker files should strictly align to 8-byte boundary
- default value is the same as before patch
- system_stm32f1xx.c file is copied to family level with all other ST cube files
- specific clock configuration is now in a new file: system_clock.c (target level)
In this commit, the analogin_s structure is moved to commonn_objects.h file
to limit the duplicaion.
The ADC handle is moved from a global variable to a struct member of the
analogin object. This allows multiple ADC instances to work correctly.
Note that State needs to be explicitely set to HAL_ADC_STATE_RESET
because the object is not zero initialized.
Remove HAL_Init and related code from SystemInit and move it to
mbed_sdk_init. The function SystemInit is called early in the boot
sequence before RAM is initialized or the VTOR is setup, so it should
not be used to perform the HAL initialization.
This fixes crashes due the vector table being used before it has been
relocated.
For STM32 targets using a 32-bit timer for the microsecond ticker, the
driver did not properly handle timestamps that are in the past. It
would just blindly set the compare register to the requested timestamp,
resulting in the interrupt being serviced up to 4295 seconds late
(i.e. after the 32-bit timer counts all the way around to hit the
timestamp again).
This problem can easily be reproduced by creating a Timeout object
then calling the timeout's attach_us() member function to attach a
callback with a timeout of 0 us. The callback will not get called for
over 2147 seconds, and possibly up to 4295 seconds late if no other
microsecond ticker events are getting scheduled in the meantime.
Now, after the compare register has been set, the timestamp is checked
against the current time to see if the timestamp is in the past, and
if so, the compare event is manually set.
NOTE: By checking if the timestamp is in the past after configuring the
capture register, we ensure proper handling in the case where the timer
updates past the timestamp while setting the capture register.
Revert HRM1017 file source deletion
Added in small comment next to additions
Added mapping to BTN-labelled switches
Added mapping to USER_BUTTON-labelled switches
Undo incorrect mapping to SWIO pin in NORDIC target
Only one point of attention:
STM_MODE_ANALOG_ADC_CONTROL is a specific mode that is only supported on L4.
So STM_MODE_ANALOG_ADC_CONTROL was moved to index 13 (last entry)
of gpio_mode table so that all the other modes are common and only the last
one is specific.