Set correct SYSMPU register for proper USB operation. This bug was
introduced when the SYSMPU register names and defines were updated
in the commit:
"K64F: Updated the SYSMPU SDK driver"
93f8cfed05
Make the following improvements and fixes:
1.
Update the Kinetis USB driver so that endpointReadResult only reads the
result of the last read and does not trigger a new read. Instead
move the code to trigger new reads into endpointRead.
2.
Fix the race condition in controlIn caused by a call to
EP0read() followed immediately by EP0readStage(). This is done by
setting up to read the next setup packet (ignoring the status stage)
in endpointReadResult rather than in EP0readStage. This makes the
function EP0readStage unnecissary.
3.
Remove the Kinetis workaround in controlOut in USBDevice.cpp since
point 2 fixes this bug. For more info on this see the PR which
added this workaround - https://github.com/ARMmbed/mbed-os/pull/414
The ISTAT register is write 1 to clear. Because of this ORing this
register with itself fill clear all bits that are set. This patch
updates the code to use plain assignment so only desired
bit is cleared.