Commit Graph

11 Commits (2aa2b7eb002812d23bdcb8b3fe619eacbd21a737)

Author SHA1 Message Date
jeromecoutant 3721ac44d2 STM32 serial RX/TX active patch
In serial_tx_active and serial_rx_active functions,
we check the internal state value with

HAL_UART_STATE_BUSY_TX = 0x21U,
HAL_UART_STATE_BUSY_RX = 0x22U,

It seems that value can also be :
HAL_UART_STATE_BUSY_TX_RX = 0x23U,
2018-06-28 18:05:52 +02:00
jeromecoutant ecffec8336 TARGET_STM32L1 astyle 2018-06-27 14:44:37 +02:00
jeromecoutant e7c4120550 STM32L1 : correct compilation warnings 2018-04-12 10:55:16 +02:00
bcostm 665d4a8003 STM32 serial: improve irq index management for L1 devices 2018-01-29 17:23:21 +01:00
jeromecoutant 6d64c2fbf4 STM32 UART init update
- serial_init, serial_free and serial_baud function moved from serial_device.c (specific to each STM32 family) to serial_api.c (common STM32 file)
- default baudrate value was hardcoded to 9600
  - Value is set now to MBED_CONF_PLATFORM_STDIO_BAUD_RATE for STDIO
  - Value is set now to MBED_CONF_PLATFORM_DEFAULT_SERIAL_BAUD_RATE for other use
- UART init will not be stopped before calling serial_baud function
2017-11-23 14:47:54 +01:00
bcostm ad55bc26dc STM32: Remove GCC_ARM compilation warnings 2017-10-17 14:04:59 +02:00
Laurent MEUNIER b5cbaaa0d0 STM32: Serial - use TXE as tx_irq instead of TC
TXE indicates that a byte can be written to UART register for sending,
while TC indicates that last byte was completely sent. So the TXE flag
can be used in case of interrupt based Serial communication, to allow
faster and efficient application buffer emptying.

Also TXE flag will be erased from the interrupt when writing to register.
In case there is nothing to write in the register, the application is
expected to disable the interrupt.
2017-07-17 08:46:00 +02:00
Laurent MEUNIER 85711eb09e STM32: Serial - do no clear RXNE flag
The RXNE flag is getting cleared when reading Data Register so it should
not be cleared here. Especially in case of high data rate, another byte of
data could have received during irq_handler call and clearing the flag
would read and discard this data which would be lost for application.
2017-07-17 08:46:00 +02:00
Laurent MEUNIER f77ecf4e12 STM32: Put some serial code in common between families 2017-06-09 13:30:54 +02:00
Laurent MEUNIER c5c33f1d0f STM32: serial: clear Overrun flag if it is set when checking if readable
Note that this could have side effects on the application as it would
not be aware that data has been missed. This may be later solved by
adding an error management parameter to the Serial API in mbed.

The advantage is that the serial link can work again.
2017-06-08 17:01:30 +02:00
Francisco J. Manno 5e98da14d3 STM32s Serial does not properly handle parity bits
Reworked the serial_format() function for STM32F0x
devices to take the format in the form:
data_bits - parity - stop_bits

E.g. 8 - N - 1

where data_bits exclude the parity bit.
Added a case for 7 bits data as at least the chips
STM32F0x1/STM32F0x2/STM32F0x8 support 7 bits data.

Consolidated serial_format() and uart_init()
functions into a general TARGET_STM serial_api.c
file since the functions are common to all STM targets.

Fixes #4189
2017-05-30 17:17:20 +01:00