Do not ticker read in ISR, use reminder to schedule the next interrupt, this should make ticker much faster.
read - disable Timer0 while reading it, if ISR is pending just reread the time again via read() function
These 2 improvements should decrease time spent when reading/scheduling ticker
events.
This commit completely rewrote flash_api.c in a few places so kicked out changes from Master and accepted the branch changes.
F429 + F439 : changes after code review
GetSector has been rewritten
Use serial-box of Nordic nRF5 SDK to share resource between
SPI and I2C.
SPI is allocated from highest hw instance number resource in order
to allocate as many I2C instances as possible.
Device needs to wait for connectivity:
-routers will create new network and get local connectivity
-end device will get connectivity once attached to existing network
-devices without network settings gets connectivity once
commissioned and attached to network
Signed-off-by: Kari <kari.haapalehto@arm.com>
Unlike the other disk_ioctl options, GET_SECTOR_SIZE is interpreted
as a 16-bit WORD, instead of a 32-bit DWORD. This caused an unaligned
access error on M0 platforms.
PPP is running close to the edge of its default thread stack size of 512 bytes. When it experiences an FCS error on the incoming data (for example. caused by character loss when the incoming serial rate is too high for it to process in time) it performs some additional work which overruns the thread's stack, hitting the OS "stack underflow" check. Increasing the PPP stack size to 768 bytes resolves this problem.
The symbol Systick_Handler was defined as a weak symbol in us_ticker.c and
startup_nRF51822.s. While it work as expected when an application is compiled
from mbed OS source code it creates a duplicate symbol issue when mbed OS is
bundled as a library.
Depending on families, different HAL macros are defined to check the
state of serial interrupts. In several cases, we can find only 1 macro:
__HAL_UART_GET_IT_SOURCE
Checks whether the specified UART interrupt has occurred or not
But in F0, F3, F7, L0, L4 there are 2 different macros
__HAL_UART_GET_IT
Checks whether the specified UART interrupt has occurred or not
__HAL_UART_GET_IT_SOURCE
Checks whether the specified UART interrupt source is enabled.
In the later case, __HAL_UART_GET_IT_SOURCE was being used so far,
but actually needs to be replaced by __HAL_UART_GET_IT. Using the right
macro, we also check the proper flags accordingly.
inc paths might be a list or might not be (just single string). If they don't, we are ending up with non valid include paths (one letter include paths).
This as result would not compile.
This is only an issue when multiple fatfss are used simultaneously.
Repeated use of a single fatfs instance (even with different storages)
do not show this issue.
Full support requires path prefixes being applied for every function
that takes a path. Note: this is only required filesystems after the
first mounted filesystem. The first filesystem has no penalty.