# aqualinkd.conf
|
|
#
|
|
|
|
# The directory where the web files are stored
|
|
#web_directory=/var/www/aqualinkd/
|
|
web_directory=/nas/data/Development/Raspberry/AqualinkD/web
|
|
|
|
# Log to file, comment out if you do not want to log to file
|
|
#log_file=/var/log/aqualinkd.log
|
|
|
|
# The log level. [DEBUG, INFO, NOTICE, WARNING, ERROR]
|
|
# Pick the highest level, and all levels below will be sent to syslog.
|
|
# your syslog settings may be set to only display messages above a certian level
|
|
# in which case make sure you use the log_file settings to capture everything
|
|
# you want when debugging
|
|
# so, NOTICE also prints WARNING & ERROR
|
|
# DEBUG would print everything possible
|
|
|
|
#log_level=DEBUG_SERIAL
|
|
#log_level=DEBUG
|
|
#log_level=INFO
|
|
log_level=NOTICE
|
|
|
|
# AQUA_LOG 1
|
|
# NET_LOG 2
|
|
# AQRS_LOG 4
|
|
# ONET_LOG 8
|
|
# IAQT_LOG 16
|
|
# PDA_LOG 32
|
|
# RSSA_LOG 64
|
|
# DJAN_LOG 128
|
|
# DPEN_LOG 256
|
|
# RSSD_LOG 512 // Serial connection
|
|
# PROG_LOG 1024
|
|
# DBGT_LOG 2048
|
|
# TIMR_LOG 4096
|
|
|
|
|
|
#debug_log_mask = 1
|
|
#debug_log_mask = 2
|
|
#debug_log_mask = 4
|
|
#debug_log_mask = 8
|
|
debug_log_mask = 16
|
|
#debug_log_mask = 32
|
|
#debug_log_mask = 64
|
|
#debug_log_mask = 256
|
|
#debug_log_mask = 512
|
|
debug_log_mask = 1024
|
|
#debug_log_mask = 2048
|
|
#debug_log_mask = 4096
|
|
|
|
# Log any packets from this device. (less outpit that DEBUG_SERIAL)
|
|
#debug_log_mask = 512 - MUST be set for this to work.
|
|
RSSD_LOG_filter = 0x33
|
|
|
|
display_warnings_in_web = yes
|
|
rs485_frame_delay = 4
|
|
|
|
# The socket port that the daemon listens to
|
|
# If you change this from 80, remember to update aqualink.service.avahi
|
|
socket_port = 80
|
|
|
|
# The serial port the daemon access to read the Aqualink RS8
|
|
serial_port=/dev/ttyUSB0
|
|
#serial_port=/dev/ttyUSB1
|
|
#serial_port=/dev/null
|
|
|
|
override_freeze_protect = no
|
|
|
|
# mqtt stuff
|
|
mqtt_address = trident:1883
|
|
#mqtt_user = someusername
|
|
#mqtt_passwd = somepassword
|
|
|
|
#mqtt_dz_pub_topic = domoticz/in
|
|
#mqtt_dz_sub_topic = domoticz/out
|
|
mqtt_aq_topic = aqualinkd-test
|
|
|
|
# The id of the Aqualink terminal device. Devices probed by RS8 master are:
|
|
# 08-0b, 10-13, 18-1b, 20-23, 28-2b, 30-33, 38-3b, 40-43
|
|
#
|
|
# Working RS 0x0a 0x0b 0x09 0x08
|
|
|
|
#device_id=0x0a
|
|
#device_id=0xFF # For testing one touch, don't use kaypad
|
|
#device_id=0x00
|
|
#device_id=0x60
|
|
device_id=0x33
|
|
|
|
#rssa_device_id=0x48
|
|
|
|
# The ID for extended settings, These are ONE TOUCH MACROS & VARIABLE SPEED PUMP RPM
|
|
# Do not enable this if you don't use either, you'll just waste memory and cpu cycles
|
|
# Valid ID's are 0x40, 0x41, 0x42 & 0x43.
|
|
# If you have a one touch remote do not use Ox40
|
|
#extended_device_id=0x43
|
|
#extended_device_id=0x33
|
|
|
|
# If you have extended_device_id set, then you can also use that ID for programming some features.
|
|
# This means that you can turn things on/off while AqualinkD is programming certian features.
|
|
# At the moment only heater setpoints & swg boost is on the extended device programming
|
|
#extended_device_id_programming = yes
|
|
#extended_device_id_programming = no
|
|
|
|
# Not documented
|
|
#serial_readahead_b4_write = yes
|
|
#mqtt_timed_update = no
|
|
#thread_netservices = yes
|
|
#rs_poll_speed = -1
|
|
#rs_poll_speed = 1
|
|
rs485_frame_delay = 4
|
|
|
|
# Your RS panel size. ie 4, 6, 8, 12 or 16 relates to RS4, RS6, RS8, RS12 or RS16.
|
|
# VERY important that you select 12 or 16, if you have either of those size panels.
|
|
# Also don't think setting a 12 when you have a 8 will give you 4 more accessories to control, it won't the
|
|
# panel information is needed as different panels use different bits within the RS protocol for status and key
|
|
# presses.
|
|
#rs_panel_size = 12
|
|
#panel_type = RS-2/6 Dual
|
|
#panel_type = RS-4 Only
|
|
#panel_type = RS-4 Combo
|
|
#panel_type = RS-6 Only
|
|
#panel_type = RS-8 Combo
|
|
panel_type = PD-8 Combo
|
|
#panel_type = RS-16 Combo
|
|
#panel_type = RS-2/14 Dual
|
|
|
|
#panel_type = RS-8 Only
|
|
#panel_type_size = 8
|
|
#panel_type_combo = yes
|
|
#panel_type_dual = no
|
|
#panel_type_pda = no
|
|
#panel_type_rs = yes
|
|
|
|
#network_poll_speed = 1
|
|
|
|
keep_paneltime_synced = yes
|
|
|
|
#pda_mode = yes
|
|
|
|
#use_PDA_auxiliary = yes
|
|
|
|
# Read information from these devices directly from the RS485 bus as well as control panel.
|
|
#read_RS485_swg = yes
|
|
#read_RS485_ePump = no
|
|
#read_RS485_vsfPump = no
|
|
|
|
|
|
# F to C conversions
|
|
convert_mqtt_temp_to_c = yes
|
|
convert_dz_temp_to_c = yes
|
|
|
|
# by default use pool temp as spa temp when spa is off, enable below to report 0 as spa temp when off.
|
|
report_zero_spa_temp = yes
|
|
report_zero_pool_temp = no
|
|
|
|
# Light probramming mode. 0=safe mode, but slow.
|
|
# any number greater is seconds to wait between button presses.
|
|
# 0.4 seems to be the minimum. (workd for light modes below 10 presses)
|
|
# 0.6 seems to work about 95% of the time, but above 20 presses can be hit or miss.
|
|
# 0 will simply wait for the controler to send the response back before sending the next, so is equivelent to about 1.2
|
|
light_programming_mode=0
|
|
|
|
# Light programming assumes light needs to be on before sending pulse (above setting)
|
|
# If the light is off when request is made to change "light show", then the below value are used
|
|
light_programming_initial_on=15
|
|
|
|
# Turn the light off for below time before start programmig puleses.
|
|
light_programming_initial_off=12
|
|
|
|
# Try to use labels from Control Panel.
|
|
#use_panel_aux_labels=yes
|
|
|
|
# If you have a SWG, set this to yes. AqualinkD can only detect a SWG if it's on, so after a restart
|
|
# you will not see/access a SWG until the the next time the pump is on.
|
|
force_SWG = yes
|
|
|
|
# Please see forum for this, only set to yes when logging information to support
|
|
# new devices. Inflrmation will be written to /tmp/RS485.log & /tmp/RS485_raw.log respectively
|
|
debug_RSProtocol_packets = no
|
|
debug_RSProtocol_bytes = no
|
|
|
|
|
|
# Domoticz ID's for temps.
|
|
#air_temp_dzidx=13
|
|
#pool_water_temp_dzidx=14
|
|
#spa_water_temp_dzidx=15
|
|
#SWG_percent_dzidx=998
|
|
#SWG_PPM_dzidx=999
|
|
#SWG_percent_dzidx=153
|
|
#SWG_PPM_dzidx=152
|
|
#SWG_Status_dzidx=157
|
|
|
|
#
|
|
# | RS-6 Combo | RS-6 Only | RS-8 Combo | RS-2/6 Dual | RS-2/10 Dual | RS-16 Combo |
|
|
# --------------------------------------------------------------------------------------------
|
|
# Button_01 | Filter Pump | Filter Pump | Filter Pump | Filter Pump | Filter Pump | Filter Pump |
|
|
# Button_02 | Spa | Aux_1 | Spa | Spa | Spa | Spa |
|
|
# Button_03 | Aux 1 | Aux 2 | Aux 1 | Aux 1 | Aux 1 | Aux 1 |
|
|
# Button_04 | Aux 2 | Aux 3 | Aux 2 | Aux 2 | Aux 2 | Aux 2 |
|
|
# Button_05 | Aux 3 | Aux 4 | Aux 3 | Aux 3 | Aux 3 | Aux 3 |
|
|
# Button_06 | Aux 4 | Aux 5 | Aux 4 | Aux 4 | Aux 4 | Aux 4 |
|
|
# Button_07 | Aux 5 | Temp 1 | Aux 5 | Aux 5 | Aux 5 | Aux 5 |
|
|
# Button_08 | Pool Heater | Temp 2 | Aux 6 | Aux 6 | Aux 6 | Aux 6 |
|
|
# Button_09 | Spa Heater | Solar Heater | Aux 7 | Pool Heater | Aux B1 | Aux 7 |
|
|
# Button_10 | Solar Heater | | Pool Heater | Spa Heater | Aux B2 | Aux B1 |
|
|
# Button_11 | | | Spa Heater | Solar Heater | Aux B3 | Aux B2 |
|
|
# Button_12 | | | Solar Heater | | Aux B4 | Aux B3 |
|
|
# Button_13 | | | | | Pool Heater | Aux B4 |
|
|
# Button_14 | | | | | Spa Heater | Aux B5 |
|
|
# Button_15 | | | | | Solar Heater | Aux B6 |
|
|
# Button_16 | | | | | | Aux B7 |
|
|
# Button_17 | | | | | | Aux B8 |
|
|
# Button_18 | | | | | | Pool Heater |
|
|
# Button_19 | | | | | | Spa Heater |
|
|
# Button_20 | | | | | | Solar Heater |
|
|
|
|
|
|
|
|
#
|
|
# Pentair pump ID's
|
|
# 0x60 to 0x6F (0x60, 0x61 0x62, 0x63, 0x64, 0x65, 0x66, 0x67, 0x68, 0x69, 0x6A, 0x6B, 0x6C, 0x6D, 0x6E, 0x6F)
|
|
# Jandy pump ID's
|
|
# 0x78, 0x79, 0x7A, 0x7B
|
|
|
|
# button_xx_lightMode = (0=Aqualink program, 1=Jandy, 2=Jandy LED, 3=SAm/SAL, 4=Color Logic, 5=Intellibrite)
|
|
|
|
# Labels for standard butons (shown in web UI), and domoticz idx's
|
|
button_01_label=Filter Pump
|
|
#button_01_dzidx=37
|
|
button_01_pumpID=0x78
|
|
#button_01_PDA_label=FILTER PUMP
|
|
button_01_pumpIndex=1
|
|
|
|
button_02_label=Spa
|
|
#button_02_dzidx=38
|
|
#button_02_pumpID= 0x78
|
|
#button_02_pumpIndex=3
|
|
#button_02_PDA_label=SPA
|
|
|
|
button_03_label=Aux1
|
|
#button_03_dzidx=39
|
|
button_03_pumpID=0x61
|
|
button_03_pumpIndex=3
|
|
|
|
button_04_label=Aux2
|
|
#button_04_dzidx=40
|
|
button_04_pumpID=0x60
|
|
button_04_pumpIndex=2
|
|
|
|
button_05_label=Aux3
|
|
#button_05_dzidx=41
|
|
button_05_lightMode=4
|
|
|
|
button_06_label=Aux4
|
|
#button_06_dzidx=42
|
|
#button_06_lightMode=1
|
|
#button_06_pumpIndex=4
|
|
|
|
button_07_label=Aux5
|
|
#button_07_label=NONE
|
|
#button_07_dzidx=43
|
|
#button_07_lightMode=0
|
|
|
|
button_08_label=Aux6
|
|
|
|
#button_09_label=Fountain
|
|
|
|
button_10_label=Pool Heat
|
|
#button_10_dzidx=44
|
|
|
|
button_11_label=Spa Heat
|
|
#button_11_dzidx=56
|
|
|
|
#button_12_label=Solar Heater
|
|
#button_12_label=Solar Heater
|
|
#button_12_dzidx=NONE
|
|
|
|
# RS-8 & RS-6 STOP HERE
|
|
# This is for RS-12 & RS-16 only.
|
|
|
|
#button_12_label=Aux B1
|
|
#button_13_label=
|
|
#button_14_label=
|
|
#button_15_label=
|
|
#button_16_label=
|
|
#button_17_label=Pool Heater
|
|
#button_18_label=Spa Heater
|
|
#button_19_label=Solar Heater
|