mirror of https://github.com/milvus-io/milvus.git
Update design about O1-1 (#5268)
Signed-off-by: yangxuan <xuan.yang@zilliz.com> The design procedure can be seen: #5220pull/5274/head
parent
e8ceb37f81
commit
ca03488c83
|
@ -43,15 +43,70 @@ There're some problems I haven't thought of.
|
|||
|
||||
## TODO
|
||||
|
||||
### 1. DataNode no longer interacts with Etcd except service registering.
|
||||
### 1. DataNode no longer interacts with Etcd except service registering
|
||||
|
||||
**O1-1**. DataService rather than DataNode saves binlog paths into Etcd. 1 Day
|
||||
#### **O1-1** DataService rather than DataNode saves binlog paths into Etcd
|
||||
|
||||

|
||||
|
||||
##### Auto-flush with manul-flush
|
||||
|
||||
Manul-flush means that the segment is sealed, and DataNode is told to flush by DataService. The completion of
|
||||
manul-flush requires ddl and insert data both flushed, and a flush completed message will be published to
|
||||
msgstream by DataService. In this case, not only do binlog paths need to be stored, but also msg-positions.
|
||||
|
||||
Auto-flush means that the segment isn't sealed, but the buffer of insert/ddl data in DataNode is full,
|
||||
DataNode automatically flushs these data. Those flushed binlogs' paths are buffered in DataNode, waiting for the next
|
||||
manul-flush and upload to DataServce together.
|
||||
|
||||
##### DataService RPC Design
|
||||
|
||||
```proto
|
||||
rpc SaveBinlogPaths(SaveBinlogPathsRequest) returns (common.Status){}
|
||||
|
||||
|
||||
message ID2PathList {
|
||||
int64 ID = 1;
|
||||
repeated string Paths = 2;
|
||||
}
|
||||
|
||||
message SaveBinlogPathsRequest {
|
||||
common.MsgBase base = 1;
|
||||
int64 segmentID = 2;
|
||||
int64 collectionID = 3;
|
||||
ID2PathList field2BinlogPaths = 4;
|
||||
ID2PathList coll2TsBinlogPaths = 5;
|
||||
ID2PathList coll2DdlBinlogPaths = 6;
|
||||
repeated internal.MsgPosition start_positions = 7;
|
||||
repeated internal.MsgPosition end_positions = 8;
|
||||
}
|
||||
```
|
||||
|
||||
##### DataService Etcd Binlog Meta Design
|
||||
|
||||
The same as DataNode
|
||||
|
||||
```proto
|
||||
message FieldFlushMeta {
|
||||
int64 fieldID = 1;
|
||||
repeated string binlog_paths = 2;
|
||||
}
|
||||
|
||||
message SegmentFlushMeta{
|
||||
int64 segmentID = 1;
|
||||
bool is_flushed = 2;
|
||||
repeated FieldFlushMeta fields = 5;
|
||||
}
|
||||
|
||||
message DDLFlushMeta {
|
||||
int64 collectionID = 1;
|
||||
repeated string binlog_paths = 2;
|
||||
}
|
||||
```
|
||||
|
||||
**O1-2**. DataNode registers itself to Etcd when started. 1 Day
|
||||
#### **O1-2** DataNode registers itself to Etcd when started
|
||||
|
||||
### 2. DataNode gets start and end MsgPositions of all channels, and report to DataService after flushing.
|
||||
### 2. DataNode gets start and end MsgPositions of all channels, and report to DataService after flushing
|
||||
|
||||
**O2-1**. Set start and end positions while publishing ddl messages. 0.5 Day
|
||||
|
||||
|
|
Loading…