In a Kubernetes cluster, a {{< glossary_tooltip text="node" term_id="node" >}}
|
||||
can be shutdown in a planned graceful way or unexpectedly because of reasons such
|
||||
as a power outage or something else external. A node shutdown could lead to workload
|
||||
failure if the node is not drained before the shutdown. A node shutdown can be
|
||||
either **graceful** or **non-graceful**.
|
||||
-->
|
||||
在 Kubernetes 集群中,{{< glossary_tooltip text="节点" term_id="node" >}}可以按计划的体面方式关闭,
|
||||
也可能因断电或其他某些外部原因被意外关闭。如果节点在关闭之前未被排空,则节点关闭可能会导致工作负载失败。
|
||||
节点可以**体面关闭**或**非体面关闭**。
|
||||
|
||||
<!-- body -->
|
||||
|
||||
<!--
|
||||
## Graceful node shutdown {#graceful-node-shutdown}
|
||||
-->
|
||||
## 节点体面关闭 {#graceful-node-shutdown}
|
||||
|
||||
{{< feature-state feature_gate_name="GracefulNodeShutdown" >}}
|
||||
|
||||
<!--
|
||||
The kubelet attempts to detect node system shutdown and terminates pods running on the node.
|
||||
|
||||
Kubelet ensures that pods follow the normal
|
||||
[pod termination process](/docs/concepts/workloads/pods/pod-lifecycle/#pod-termination)
|
||||
during the node shutdown. During node shutdown, the kubelet does not accept new
|
||||
Pods (even if those Pods are already bound to the node).
|
||||
-->
|
||||
kubelet 会尝试检测节点系统关闭事件并终止在节点上运行的所有 Pod。
|
||||
|
||||
在节点终止期间,kubelet 保证 Pod 遵从常规的
|
||||
[Pod 终止流程](/zh-cn/docs/concepts/workloads/pods/pod-lifecycle/#pod-termination),
|
||||
且不接受新的 Pod(即使这些 Pod 已经绑定到该节点)。
|
||||
|
||||
<!--
|
||||
The Graceful node shutdown feature depends on systemd since it takes advantage of
|
||||
[systemd inhibitor locks](https://www.freedesktop.org/wiki/Software/systemd/inhibit/) to
|
||||
delay the node shutdown with a given duration.
|
||||
-->
|
||||
节点体面关闭特性依赖于 systemd,因为它要利用
|
||||
[systemd 抑制器锁](https://www.freedesktop.org/wiki/Software/systemd/inhibit/)机制,
|
||||
在给定的期限内延迟节点关闭。
|
||||
|
||||
<!--
|
||||
Graceful node shutdown is controlled with the `GracefulNodeShutdown`
|
||||
[feature gate](/docs/reference/command-line-tools-reference/feature-gates/) which is
|
||||
enabled by default in 1.21.
|
||||
-->
|
||||
节点体面关闭特性受 `GracefulNodeShutdown`
|
||||
[特性门控](/zh-cn/docs/reference/command-line-tools-reference/feature-gates/)控制,
|
||||
在 1.21 版本中是默认启用的。
|
||||
|
||||
<!--
|
||||
Note that by default, both configuration options described below,
|
||||
`shutdownGracePeriod` and `shutdownGracePeriodCriticalPods` are set to zero,
|
||||
thus not activating the graceful node shutdown functionality.
|
||||
To activate the feature, the two kubelet config settings should be configured appropriately and
|
||||
set to non-zero values.
|
||||
-->
|
||||
注意,默认情况下,下面描述的两个配置选项,`shutdownGracePeriod` 和
|
||||
`shutdownGracePeriodCriticalPods` 都是被设置为 0 的,因此不会激活节点体面关闭功能。
|
||||
要激活此功能特性,这两个 kubelet 配置选项要适当配置,并设置为非零值。
|
||||
|
||||
<!--
|
||||
Once systemd detects or notifies node shutdown, the kubelet sets a `NotReady` condition on
|
||||
the Node, with the `reason` set to `"node is shutting down"`. The kube-scheduler honors this condition
|
||||
and does not schedule any Pods onto the affected node; other third-party schedulers are
|
||||
expected to follow the same logic. This means that new Pods won't be scheduled onto that node
|
||||
and therefore none will start.
|
||||
-->
|
||||
一旦 systemd 检测到或通知节点关闭,kubelet 就会在节点上设置一个
|
||||
`NotReady` 状况,并将 `reason` 设置为 `"node is shutting down"`。
|
||||
kube-scheduler 会重视此状况,不将 Pod 调度到受影响的节点上;
|
||||
其他第三方调度程序也应当遵循相同的逻辑。这意味着新的 Pod 不会被调度到该节点上,
|
||||
因此不会有新 Pod 启动。
|
||||
|
||||
<!--
|
||||
The kubelet **also** rejects Pods during the `PodAdmission` phase if an ongoing
|
||||
node shutdown has been detected, so that even Pods with a
|
||||
{{< glossary_tooltip text="toleration" term_id="toleration" >}} for
|
||||
`node.kubernetes.io/not-ready:NoSchedule` do not start there.
|
||||
-->
|
||||
如果检测到节点关闭正在进行中,kubelet **也会**在 `PodAdmission`
|
||||
阶段拒绝 Pod,即使是该 Pod 带有 `node.kubernetes.io/not-ready:NoSchedule`
|
||||
的{{< glossary_tooltip text="容忍度" term_id="toleration" >}},也不会在此节点上启动。
|
||||
|
||||
<!--
|
||||
At the same time when kubelet is setting that condition on its Node via the API, the kubelet also begins
|
||||
terminating any Pods that are running locally.
|
||||
-->
|
||||
同时,当 kubelet 通过 API 在其 Node 上设置该状况时,kubelet
|
||||
也开始终止在本地运行的所有 Pod。
|
||||
|
||||
<!--
|
||||
During a graceful shutdown, kubelet terminates pods in two phases:
|
||||
|
||||
1. Terminate regular pods running on the node.
|
||||
2. Terminate [critical pods](/docs/tasks/administer-cluster/guaranteed-scheduling-critical-addon-pods/#marking-pod-as-critical)
|
||||
running on the node.
|
||||
-->
|
||||
在体面关闭节点过程中,kubelet 分两个阶段来终止 Pod:
|
||||
|
||||
1. 终止在节点上运行的常规 Pod。
|
||||
2. 终止在节点上运行的[关键 Pod](/zh-cn/docs/tasks/administer-cluster/guaranteed-scheduling-critical-addon-pods/#marking-pod-as-critical)。
|
||||
|
||||
<!--
|
||||
Graceful node shutdown feature is configured with two
|
||||
[`KubeletConfiguration`](/docs/tasks/administer-cluster/kubelet-config-file/) options:
|
||||
* `shutdownGracePeriod`:
|
||||
* Specifies the total duration that the node should delay the shutdown by. This is the total
|
||||
grace period for pod termination for both regular and
|
||||
[critical pods](/docs/tasks/administer-cluster/guaranteed-scheduling-critical-addon-pods/#marking-pod-as-critical).
|
||||
* `shutdownGracePeriodCriticalPods`:
|
||||
* Specifies the duration used to terminate
|
||||
[critical pods](/docs/tasks/administer-cluster/guaranteed-scheduling-critical-addon-pods/#marking-pod-as-critical)
|
||||
during a node shutdown. This value should be less than `shutdownGracePeriod`.
|
||||
-->
|
||||
节点体面关闭的特性对应两个
|
||||
[`KubeletConfiguration`](/zh-cn/docs/tasks/administer-cluster/kubelet-config-file/) 选项:
|
||||
|
||||
* `shutdownGracePeriod`:
|
||||
* 指定节点应延迟关闭的总持续时间。这是 Pod 体面终止的时间总和,不区分常规 Pod
|
||||
还是[关键 Pod](/zh-cn/docs/tasks/administer-cluster/guaranteed-scheduling-critical-addon-pods/#marking-pod-as-critical)。
|
||||
* `shutdownGracePeriodCriticalPods`:
|
||||
* 在节点关闭期间指定用于终止[关键 Pod](/zh-cn/docs/tasks/administer-cluster/guaranteed-scheduling-critical-addon-pods/#marking-pod-as-critical)
|
||||
的持续时间。该值应小于 `shutdownGracePeriod`。
|
||||
|
||||
{{< note >}}
|
||||
<!--
|
||||
There are cases when Node termination was cancelled by the system (or perhaps manually
|
||||
by an administrator). In either of those situations the
|
||||
Node will return to the `Ready` state. However Pods which already started the process
|
||||
of termination
|
||||
will not be restored by kubelet and will need to be re-scheduled.
|
||||
-->
|
||||
在某些情况下,节点终止过程会被系统取消(或者可能由管理员手动取消)。
|
||||
无论哪种情况下,节点都将返回到 `Ready` 状态。然而,已经开始终止进程的
|
||||
Pod 将不会被 kubelet 恢复,需要被重新调度。
|
||||
{{< /note >}}
|
||||
|
||||
<!--
|
||||
For example, if `shutdownGracePeriod=30s`, and
|
||||
`shutdownGracePeriodCriticalPods=10s`, kubelet will delay the node shutdown by
|
||||
30 seconds. During the shutdown, the first 20 (30-10) seconds would be reserved
|
||||
for gracefully terminating normal pods, and the last 10 seconds would be
|
||||
reserved for terminating [critical pods](/docs/tasks/administer-cluster/guaranteed-scheduling-critical-addon-pods/#marking-pod-as-critical).
|
||||
-->
|
||||
例如,如果设置了 `shutdownGracePeriod=30s` 和 `shutdownGracePeriodCriticalPods=10s`,
|
||||
则 kubelet 将延迟 30 秒关闭节点。
|
||||
在关闭期间,将保留前 20(30 - 10)秒用于体面终止常规 Pod,
|
||||
而保留最后 10 秒用于终止[关键 Pod](/zh-cn/docs/tasks/administer-cluster/guaranteed-scheduling-critical-addon-pods/#marking-pod-as-critical)。
|
||||
|
||||
{{< note >}}
|
||||
<!--
|
||||
When pods were evicted during the graceful node shutdown, they are marked as shutdown.
|
||||
Running `kubectl get pods` shows the status of the evicted pods as `Terminated`.
|
||||
And `kubectl describe pod` indicates that the pod was evicted because of node shutdown:
|
||||
-->
|
||||
当 Pod 在正常节点关闭期间被驱逐时,它们会被标记为关闭。
|
||||
运行 `kubectl get pods` 时,被驱逐的 Pod 的状态显示为 `Terminated`。
|
||||
并且 `kubectl describe pod` 表示 Pod 因节点关闭而被驱逐:
|
||||
|
||||
```
|
||||
Reason: Terminated
|
||||
Message: Pod was terminated in response to imminent node shutdown.
|
||||
```
|
||||
{{< /note >}}
|
||||
|
||||
<!--
|
||||
### Pod Priority based graceful node shutdown {#pod-priority-graceful-node-shutdown}
|
||||
-->
|
||||
### 基于 Pod 优先级的节点体面关闭 {#pod-priority-graceful-node-shutdown}
|
||||
|
||||
{{< feature-state feature_gate_name="GracefulNodeShutdownBasedOnPodPriority" >}}
|
||||
|
||||
<!--
|
||||
To provide more flexibility during graceful node shutdown around the ordering
|
||||
of pods during shutdown, graceful node shutdown honors the PriorityClass for
|
||||
Pods, provided that you enabled this feature in your cluster. The feature
|
||||
allows cluster administers to explicitly define the ordering of pods
|
||||
during graceful node shutdown based on
|
||||
[priority classes](/docs/concepts/scheduling-eviction/pod-priority-preemption/#priorityclass).
|
||||
-->
|
||||
为了在节点体面关闭期间提供更多的灵活性,尤其是处理关闭期间的 Pod 排序问题,
|
||||
节点体面关闭机制能够关注 Pod 的 PriorityClass 设置,前提是你已经在集群中启用了此功能特性。
|
||||
此特性允许集群管理员基于 Pod
|
||||
的[优先级类(Priority Class)](/zh-cn/docs/concepts/scheduling-eviction/pod-priority-preemption/#priorityclass)
|
||||
显式地定义节点体面关闭期间 Pod 的处理顺序。
|
||||
|
||||
<!--
|
||||
The [Graceful Node Shutdown](#graceful-node-shutdown) feature, as described
|
||||
above, shuts down pods in two phases, non-critical pods, followed by critical
|
||||
pods. If additional flexibility is needed to explicitly define the ordering of
|
||||
pods during shutdown in a more granular way, pod priority based graceful
|
||||
shutdown can be used.
|
||||
-->
|
||||
前文所述的[节点体面关闭](#graceful-node-shutdown)特性能够分两个阶段关闭 Pod,
|
||||
首先关闭的是非关键的 Pod,之后再处理关键 Pod。
|
||||
如果需要显式地以更细粒度定义关闭期间 Pod 的处理顺序,需要一定的灵活度,
|
||||
这时可以使用基于 Pod 优先级的体面关闭机制。
|
||||
|
||||
<!--
|
||||
When graceful node shutdown honors pod priorities, this makes it possible to do
|
||||
graceful node shutdown in multiple phases, each phase shutting down a
|
||||
particular priority class of pods. The kubelet can be configured with the exact
|
||||
phases and shutdown time per phase.
|
||||
-->
|
||||
当节点体面关闭能够处理 Pod 优先级时,节点体面关闭的处理可以分为多个阶段,
|
||||
每个阶段关闭特定优先级类的 Pod。可以配置 kubelet 按确切的阶段处理 Pod,
|
||||
且每个阶段可以独立设置关闭时间。
|
||||
|
||||
<!--
|
||||
Assuming the following custom pod
|
||||
[priority classes](/docs/concepts/scheduling-eviction/pod-priority-preemption/#priorityclass)
|
||||
in a cluster,
|
||||
-->
|
||||
假设集群中存在以下自定义的 Pod
|
||||
[优先级类](/zh-cn/docs/concepts/scheduling-eviction/pod-priority-preemption/#priorityclass)。
|
||||
|
||||
<!--
|
||||
|Pod priority class name|Pod priority class value|
|
||||
|-------------------------|------------------------|
|
||||
|`custom-class-a` | 100000 |
|
||||
|`custom-class-b` | 10000 |
|
||||
|`custom-class-c` | 1000 |
|
||||
|`regular/unset` | 0 |
|
||||
-->
|
||||
| Pod 优先级类名称 | Pod 优先级类数值 |
|
||||
|-------------------------|------------------------|
|
||||
|`custom-class-a` | 100000 |
|
||||
|`custom-class-b` | 10000 |
|
||||
|`custom-class-c` | 1000 |
|
||||
|`regular/unset` | 0 |
|
||||
|
||||
<!--
|
||||
Within the [kubelet configuration](/docs/reference/config-api/kubelet-config.v1beta1/)
|
||||
the settings for `shutdownGracePeriodByPodPriority` could look like:
|
||||
-->
|
||||
在 [kubelet 配置](/zh-cn/docs/reference/config-api/kubelet-config.v1beta1/)中,
|
||||
`shutdownGracePeriodByPodPriority` 看起来可能是这样:
|
||||
|
||||
<!--
|
||||
|Pod priority class value|Shutdown period|
|
||||
|------------------------|---------------|
|
||||
| 100000 |10 seconds |
|
||||
| 10000 |180 seconds |
|
||||
| 1000 |120 seconds |
|
||||
| 0 |60 seconds |
|
||||
-->
|
||||
| Pod 优先级类数值 | 关闭期限 |
|
||||
|------------------------|-----------|
|
||||
| 100000 | 10 秒 |
|
||||
| 10000 | 180 秒 |
|
||||
| 1000 | 120 秒 |
|
||||
| 0 | 60 秒 |
|
||||
|
||||
<!--
|
||||
The corresponding kubelet config YAML configuration would be:
|
||||
-->
|
||||
对应的 kubelet 配置 YAML 将会是:
|
||||
|
||||
```yaml
|
||||
shutdownGracePeriodByPodPriority:
|
||||
- priority: 100000
|
||||
shutdownGracePeriodSeconds: 10
|
||||
- priority: 10000
|
||||
shutdownGracePeriodSeconds: 180
|
||||
- priority: 1000
|
||||
shutdownGracePeriodSeconds: 120
|
||||
- priority: 0
|
||||
shutdownGracePeriodSeconds: 60
|
||||
```
|
||||
|
||||
<!--
|
||||
The above table implies that any pod with `priority` value >= 100000 will get
|
||||
just 10 seconds to stop, any pod with value >= 10000 and < 100000 will get 180
|
||||
seconds to stop, any pod with value >= 1000 and < 10000 will get 120 seconds to stop.
|
||||
Finally, all other pods will get 60 seconds to stop.
|
||||
|
||||
One doesn't have to specify values corresponding to all of the classes. For
|
||||
example, you could instead use these settings:
|
||||
-->
|
||||
上面的表格表明,所有 `priority` 值大于等于 100000 的 Pod 停止期限只有 10 秒,
|
||||
所有 `priority` 值介于 10000 和 100000 之间的 Pod 停止期限是 180 秒,
|
||||
所有 `priority` 值介于 1000 和 10000 之间的 Pod 停止期限是 120 秒,
|
||||
其他所有 Pod 停止期限是 60 秒。
|
||||
|
||||
用户不需要为所有的优先级类都设置数值。例如,你也可以使用下面这种配置:
|
||||
|
||||
<!--
|
||||
|Pod priority class value|Shutdown period|
|
||||
|------------------------|---------------|
|
||||
| 100000 |300 seconds |
|
||||
| 1000 |120 seconds |
|
||||
| 0 |60 seconds |
|
||||
-->
|
||||
| Pod 优先级类数值 | 关闭期限 |
|
||||
|------------------------|-----------|
|
||||
| 100000 | 300 秒 |
|
||||
| 1000 | 120 秒 |
|
||||
| 0 | 60 秒 |
|
||||
|
||||
<!--
|
||||
In the above case, the pods with `custom-class-b` will go into the same bucket
|
||||
as `custom-class-c` for shutdown.
|
||||
|
||||
If there are no pods in a particular range, then the kubelet does not wait
|
||||
for pods in that priority range. Instead, the kubelet immediately skips to the
|
||||
next priority class value range.
|
||||
-->
|
||||
在上面这个场景中,优先级类为 `custom-class-b` 的 Pod 会与优先级类为 `custom-class-c`
|
||||
的 Pod 在关闭时按相同期限处理。
|
||||
|
||||
如果在特定的范围内不存在 Pod,则 kubelet 不会等待对应优先级范围的 Pod。
|
||||
kubelet 会直接跳到下一个优先级数值范围进行处理。
|
||||
|
||||
<!--
|
||||
If this feature is enabled and no configuration is provided, then no ordering
|
||||
action will be taken.
|
||||
|
||||
Using this feature requires enabling the `GracefulNodeShutdownBasedOnPodPriority`
|
||||
[feature gate](/docs/reference/command-line-tools-reference/feature-gates/)
|
||||
, and setting `ShutdownGracePeriodByPodPriority` in the
|
||||
[kubelet config](/docs/reference/config-api/kubelet-config.v1beta1/)
|
||||
to the desired configuration containing the pod priority class values and
|
||||
their respective shutdown periods.
|
||||
-->
|
||||
如果此功能特性被启用,但没有提供配置数据,则不会出现排序操作。
|
||||
|
||||
使用此功能特性需要启用 `GracefulNodeShutdownBasedOnPodPriority`
|
||||
[特性门控](/zh-cn/docs/reference/command-line-tools-reference/feature-gates/),
|
||||
并将 [kubelet 配置](/zh-cn/docs/reference/config-api/kubelet-config.v1beta1/)
|
||||
中的 `shutdownGracePeriodByPodPriority` 设置为期望的配置,
|
||||
其中包含 Pod 的优先级类数值以及对应的关闭期限。
|
||||
|
||||
{{< note >}}
|
||||
<!--
|
||||
The ability to take Pod priority into account during graceful node shutdown was introduced
|
||||
as an Alpha feature in Kubernetes v1.23. In Kubernetes {{< skew currentVersion >}}
|
||||
the feature is Beta and is enabled by default.
|
||||
-->
|
||||
在节点体面关闭期间考虑 Pod 优先级的能力是作为 Kubernetes v1.23 中的 Alpha 功能引入的。
|
||||
在 Kubernetes {{< skew currentVersion >}} 中该功能是 Beta 版,默认启用。
|
||||
{{< /note >}}
|
||||
|
||||
<!--
|
||||
Metrics `graceful_shutdown_start_time_seconds` and `graceful_shutdown_end_time_seconds`
|
||||
are emitted under the kubelet subsystem to monitor node shutdowns.
|
||||
-->
|
||||
kubelet 子系统中会生成 `graceful_shutdown_start_time_seconds` 和
|
||||
`graceful_shutdown_end_time_seconds` 度量指标以便监视节点关闭行为。
|
||||
|
||||
<!--
|
||||
## Non-graceful node shutdown handling {#non-graceful-node-shutdown}
|
||||
-->
|
||||
## 处理节点非体面关闭 {#non-graceful-node-shutdown}
|
||||
|
||||
{{< feature-state feature_gate_name="NodeOutOfServiceVolumeDetach" >}}
|
||||
|
||||
<!--
|
||||
A node shutdown action may not be detected by kubelet's Node Shutdown Manager,
|
||||
either because the command does not trigger the inhibitor locks mechanism used by
|
||||
kubelet or because of a user error, i.e., the ShutdownGracePeriod and
|
||||
ShutdownGracePeriodCriticalPods are not configured properly. Please refer to above
|
||||
section [Graceful Node Shutdown](#graceful-node-shutdown) for more details.
|
||||
-->
|
||||
节点关闭的操作可能无法被 kubelet 的节点关闭管理器检测到,
|
||||
或是因为该命令没有触发 kubelet 所使用的抑制器锁机制,或是因为用户错误,
|
||||
即 ShutdownGracePeriod 和 ShutdownGracePeriodCriticalPod 配置不正确。
|
||||
请参考以上[节点体面关闭](#graceful-node-shutdown)部分了解更多详细信息。
|
||||
|
||||
<!--
|
||||
When a node is shutdown but not detected by kubelet's Node Shutdown Manager, the pods
|
||||
that are part of a {{< glossary_tooltip text="StatefulSet" term_id="statefulset" >}} will be stuck in terminating status on
|
||||
the shutdown node and cannot move to a new running node. This is because kubelet on
|
||||
the shutdown node is not available to delete the pods so the StatefulSet cannot
|
||||
create a new pod with the same name. If there are volumes used by the pods, the
|
||||
VolumeAttachments will not be deleted from the original shutdown node so the volumes
|
||||
used by these pods cannot be attached to a new running node. As a result, the
|
||||
application running on the StatefulSet cannot function properly. If the original
|
||||
shutdown node comes up, the pods will be deleted by kubelet and new pods will be
|
||||
created on a different running node. If the original shutdown node does not come up,
|
||||
these pods will be stuck in terminating status on the shutdown node forever.
|
||||
-->
|
||||
当某节点关闭但 kubelet 的节点关闭管理器未检测到这一事件时,
|
||||
在那个已关闭节点上、属于 {{< glossary_tooltip text="StatefulSet" term_id="statefulset" >}}
|
||||
的 Pod 将停滞于终止状态,并且不能移动到新的运行节点上。
|
||||
这是因为已关闭节点上的 kubelet 已不存在,亦无法删除 Pod,
|
||||
因此 StatefulSet 无法创建同名的新 Pod。
|
||||
如果 Pod 使用了卷,则 VolumeAttachments 无法从原来的已关闭节点上删除,
|
||||
因此这些 Pod 所使用的卷也无法挂接到新的运行节点上。
|
||||
最终,那些以 StatefulSet 形式运行的应用无法正常工作。
|
||||
如果原来的已关闭节点被恢复,kubelet 将删除 Pod,新的 Pod 将被在不同的运行节点上创建。
|
||||
如果原来的已关闭节点没有被恢复,那些在已关闭节点上的 Pod 将永远滞留在终止状态。
|
||||
|
||||
<!--
|
||||
To mitigate the above situation, a user can manually add the taint `node.kubernetes.io/out-of-service` with either `NoExecute`
|
||||
or `NoSchedule` effect to a Node marking it out-of-service.
|
||||
If the `NodeOutOfServiceVolumeDetach`[feature gate](/docs/reference/command-line-tools-reference/feature-gates/)
|
||||
is enabled on {{< glossary_tooltip text="kube-controller-manager" term_id="kube-controller-manager" >}}, and a Node is marked out-of-service with this taint, the
|
||||
pods on the node will be forcefully deleted if there are no matching tolerations on it and volume
|
||||
detach operations for the pods terminating on the node will happen immediately. This allows the
|
||||
Pods on the out-of-service node to recover quickly on a different node.
|
||||
-->
|
||||
为了缓解上述情况,用户可以手动将具有 `NoExecute` 或 `NoSchedule` 效果的
|
||||
`node.kubernetes.io/out-of-service` 污点添加到节点上,标记其无法提供服务。
|
||||
如果在 {{< glossary_tooltip text="kube-controller-manager" term_id="kube-controller-manager" >}}
|
||||
上启用了 `NodeOutOfServiceVolumeDetach`
|
||||
[特性门控](/zh-cn/docs/reference/command-line-tools-reference/feature-gates/),
|
||||
并且节点被污点标记为无法提供服务,如果节点 Pod 上没有设置对应的容忍度,
|
||||
那么这样的 Pod 将被强制删除,并且该在节点上被终止的 Pod 将立即进行卷分离操作。
|
||||
这样就允许那些在无法提供服务节点上的 Pod 能在其他节点上快速恢复。
|
||||
|
||||
<!--
|
||||
During a non-graceful shutdown, Pods are terminated in the two phases:
|
||||
|
||||
1. Force delete the Pods that do not have matching `out-of-service` tolerations.
|
||||
2. Immediately perform detach volume operation for such pods.
|
||||
-->
|
||||
在非体面关闭期间,Pod 分两个阶段终止:
|
||||
|
||||
1. 强制删除没有匹配的 `out-of-service` 容忍度的 Pod。
|
||||
2. 立即对此类 Pod 执行分离卷操作。
|
||||
|
||||
{{< note >}}
|
||||
<!--
|
||||
- Before adding the taint `node.kubernetes.io/out-of-service` , it should be verified
|
||||
that the node is already in shutdown or power off state (not in the middle of
|
||||
restarting).
|
||||
- The user is required to manually remove the out-of-service taint after the pods are
|
||||
moved to a new node and the user has checked that the shutdown node has been
|
||||
recovered since the user was the one who originally added the taint.
|
||||
-->
|
||||
- 在添加 `node.kubernetes.io/out-of-service` 污点之前,
|
||||
应该验证节点已经处于关闭或断电状态(而不是在重新启动中)。
|
||||
- 将 Pod 移动到新节点后,用户需要手动移除停止服务的污点,
|
||||
并且用户要检查关闭节点是否已恢复,因为该用户是最初添加污点的用户。
|
||||
{{< /note >}}
|
||||
|
||||
<!--
|
||||
### Forced storage detach on timeout {#storage-force-detach-on-timeout}
|
||||
|
||||
In any situation where a pod deletion has not succeeded for 6 minutes, kubernetes will
|
||||
force detach volumes being unmounted if the node is unhealthy at that instant. Any
|
||||
workload still running on the node that uses a force-detached volume will cause a
|
||||
violation of the
|
||||
[CSI specification](https://github.com/container-storage-interface/spec/blob/master/spec.md#controllerunpublishvolume),
|
||||
which states that `ControllerUnpublishVolume` "**must** be called after all
|
||||
`NodeUnstageVolume` and `NodeUnpublishVolume` on the volume are called and succeed".
|
||||
In such circumstances, volumes on the node in question might encounter data corruption.
|
||||
-->
|
||||
### 存储超时强制解除挂接 {#storage-force-detach-on-timeout}
|
||||
|
||||
在任何情况下,当 Pod 未能在 6 分钟内删除成功,如果节点当时不健康,
|
||||
Kubernetes 将强制解除挂接正在被卸载的卷。
|
||||
任何运行在使用了强制解除挂接卷的节点之上的工作负载,
|
||||
都将违反 [CSI 规范](https://github.com/container-storage-interface/spec/blob/master/spec.md#controllerunpublishvolume),
|
||||
该规范指出 `ControllerUnpublishVolume`
|
||||
"**必须**在调用卷上的所有 `NodeUnstageVolume` 和 `NodeUnpublishVolume` 执行且成功后被调用"。
|
||||
在这种情况下,相关节点上的卷可能会遇到数据损坏。
|
||||
|
||||
<!--
|
||||
The forced storage detach behaviour is optional; users might opt to use the "Non-graceful
|
||||
node shutdown" feature instead.
|
||||
-->
|
||||
强制存储解除挂接行为是可选的;用户可以选择使用"非体面节点关闭"特性。
|
||||
|
||||
<!--
|
||||
Force storage detach on timeout can be disabled by setting the `disable-force-detach-on-timeout`
|
||||
config field in `kube-controller-manager`. Disabling the force detach on timeout feature means
|
||||
that a volume that is hosted on a node that is unhealthy for more than 6 minutes will not have
|
||||
its associated
|
||||
[VolumeAttachment](/docs/reference/kubernetes-api/config-and-storage-resources/volume-attachment-v1/)
|
||||
deleted.
|
||||
-->
|
||||
可以通过在 `kube-controller-manager` 中设置 `disable-force-detach-on-timeout`
|
||||
配置字段来禁用超时时存储强制解除挂接。
|
||||
禁用超时强制解除挂接特性意味着,托管在异常超过 6 分钟的节点上的卷将不会保留其关联的
|
||||
[VolumeAttachment](/zh-cn/docs/reference/kubernetes-api/config-and-storage-resources/volume-attachment-v1/)。
|
||||
|
||||
<!--
|
||||
After this setting has been applied, unhealthy pods still attached to a volumes must be recovered
|
||||
via the [Non-Graceful Node Shutdown](#non-graceful-node-shutdown) procedure mentioned above.
|
||||
-->
|
||||
应用此设置后,仍然关联卷到不健康 Pod 必须通过上述[非体面节点关闭](#non-graceful-node-shutdown)过程进行恢复。
|
||||
|
||||
{{< note >}}
|
||||
<!--
|
||||
- Caution must be taken while using the [Non-Graceful Node Shutdown](#non-graceful-node-shutdown) procedure.
|
||||
- Deviation from the steps documented above can result in data corruption.
|
||||
-->
|
||||
- 使用[非体面节点关闭](#non-graceful-node-shutdown)过程时必须小心。
|
||||
- 偏离上述步骤可能会导致数据损坏。
|
||||
{{< /note >}}
|
||||
|
||||
## {{% heading "whatsnext" %}}
|
||||
|
||||
<!--
|
||||
Learn more about the following:
|
||||
* Blog: [Non-Graceful Node Shutdown](/blog/2023/08/16/kubernetes-1-28-non-graceful-node-shutdown-ga/).
|
||||
* Cluster Architecture: [Nodes](/docs/concepts/architecture/nodes/).
|
||||
-->
|
||||
了解更多以下信息:
|
||||
|
||||
- 博客:[非体面节点关闭](/zh-cn/blog/2023/08/16/kubernetes-1-28-non-graceful-node-shutdown-ga/)。
|
||||
- 集群架构:[节点](/zh-cn/docs/concepts/architecture/nodes/)。
|