openhab-docs/_addons_bindings/digitalstrom
Thomas Dietrich 826ef4abb4 Distinguish collections, improve update process (#514)
* Rename collection folders

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Change all occurences of addons and repos

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Add further corrections

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Remove temporary directories after processing

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Reduce addons menus, show current uncond.

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Fix typo

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Remove redundant addons from permalinks

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Sort UI menu entries correctly

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Split maven command

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>
2017-09-22 21:05:09 +02:00
..
doc Distinguish collections, improve update process (#514) 2017-09-22 21:05:09 +02:00
readme.md Distinguish collections, improve update process (#514) 2017-09-22 21:05:09 +02:00

readme.md

id label title type description since logo install
digitalstrom digitalSTROM digitalSTROM - Bindings binding This binding integrates the [digitalSTROM-System](http://www.digitalstrom.de/). 2x images/addons/digitalstrom.png auto

{% include base.html %}

digitalSTROM Binding

This binding integrates the digitalSTROM-System. The integration happens through the digitalSTROM-Server, which acts as a gateway to connect the digitalSTROM-Devices. The digitalSTROM-Server communicates through the digitalSTROM-Meters with the digitalSTROM-Devices, which are directly connected to the power-line.

Note: All was tested with digitalSTROM-Server firmware version 1.9.3 to 1.10.3.

various_digitalSTROM_clamps

Supported Things

digitalSTROM-Server

The digitalSTROM-Server is required for accessing any other digitalSTROM-Devices. It acts like a "bridge".

digitalSTROM-Devices

At this point almost all available GE, SW and GR digitalSTROM-Devices with a set output-mode, unequal disabled or PWM, are supported by this binding.
For that there are identically named thing types. Only the GR type has a channel (shade), which cannot be changed. The other two types add their channels dynamically affected by the set color-group and output-mode. They also automatically change or add the channels, if the color-group or output-mode has changed through the dSS-web-configuration or the configured sensor priorities of the thing have changed.

The following table shows all tested digitalSTROM-Devices with their output-modes.

HW-Type Output-Mode Tested color group
GE-KL200 switched yellow
GE-KM200 switched, dimmed yellow
GE-TKM210 switched, dimmed yellow
GE-SDM200 switched, dimmed yellow
GE-UMV200 1-10V dimmed yellow
GR-KL200 standard output-mode grey
GR-KL210 standard output-mode grey
GR-KL220 standard output-mode grey
SW-KL200 switch, powersave, wipe black, yellow
SW-UMR200 single switched, combined switch, combined 2 stage switch, combined 3 stage switch yellow , black
SW-ZWS200 switch, powersave, wipe black, yellow

digitalSTROM-Scenes

Furthermore the digitalSTROM-Scene concept is part of the digitalSTROM-Binding. These scenes are implemented as virtual things. The different scene thing types are listed in the following table.

Thing-Type-ID Label Description
appScene Apartment-Scene Represents a digitalSTROM Apartment-Scene.
zoneScene Zone-Scene Represents a digitalSTROM Zone-Scene.
groupScene Group-Scene Represents a digitalSTROM Group-Scene.
namedScene Named-Scene Represents a digitalSTROM Scene, which has a user-defined name.

Discovery

The digitalSTROM-Server is discovered by mDNS or dss.local. at the local network. Once the server is added as a thing, you have to set a user name and password or insert a valid Application-Token to authenticate with the server. If the binding is authorized, it automatically reads all supported devices, that are set up on the digitalSTROM-System and puts them into the inbox.

digitalSTROM-Scenes can be discovered, too. The background scene-discovery is deactivated by default to not flood the inbox. Otherwise it will discover so many scenes, that it can be difficult to find the searched devices.

Discoverable scenes are all user named scenes, group scenes that are reachable by local push-buttons, zone scenes and apartment scenes. The discovery also will discover all called scenes, if they aren't automatically discovered yet.

If you only want to discover one of the thing types, you can start a discovery scan on the thing type you wish have discovered. You can use the command line command, e.g.: smarthome:discovery start digitalstrom:namedScene to start the scan. To find out what thing types this binding supports please have a look at the Supported Things section.

digitalSTROM-Scenes

General

The device scene configuration will be saved persistently to the things to update the device state faster. For that each scene configuration of each device has to read out first, because of the digitalSTROM-rule 9 that requires a waiting period of one minute, that take some time so that at the first start a scene call can take some time to read it out and update the device state. To read it out faster only the discovered or called scenes will be read out.

Note: Because the digitalSTROM-Server can't inform the binding about save scene events at this time, the persistently saved scene configurations can't be updated. The current troubleshooting to read out the new scene configuration after a save scene action at the digitalSTROM-Server is the following:

  1. delete the thing to delete the persistently saved scene configuration
  2. restart the server to delete the temporary saved scene configuration
  3. add the thing again to read out the scene configuration again.

Thing Configuration

digitalSTROM-Server

The digitalSTROM-Server thing has the following configuration parameter groups: Connection configuration, Server information and General configurations.

Connection configuration

If the digitalSTROM-Server isnt found automatically, e.g. because the server isnt placed at the local network or the mDNS-service is deactivated, you have to insert the network address or URL and the authentication data manually through the graphical user interface or type it into the *.thing with textual configuration.

Parameter Label Parameter ID Description Required Advanced
Network address ipAddress Network address of the digitalSTROM-Server. true false
User name userName Name of a registered user to authenticate to the digitalSTROM-Server. user name and password or Application-Token false
Password password Password of a registered user to authenticate to the digitalSTROM-Server. user name and password or Application-Token false
Application-Token applicationToken The Application-Token to authenticate to the digitalSTROM-Server. user name and password or Application-Token false

Server information

The parameter group Server information only includes informative parameters, which have no special functionality.

Parameter Label Parameter ID Description Required Advanced
dSID dSID The unique identifier of a digitalSTOM-server. false false
digitalSTROM-Installation name dsName The user defined name of the digitalSTROM-Installation. false false

General configuration:

Here you can set general binding configuration parameters, which are shown in following table:

Parameter Label Parameter ID Description Required Advanced default
Sensor update interval sensorDataUpdateInterval Sets the seconds after the digitalSTROM-Device sensor data will be updated. If the priority is higher than 'never'. false false 60
Total power update interval totalPowerUpdateInterval Sets the interval in seconds, after the digitalSTROM total power consumption and total electric meter sensor data will be updated. false false 30
Days to be slaked trash bin devices defaultTrashBinDeleateTime Sets the days after the temporary saved digitalSTROM-Device configuration from not reachable digitalSTROM-Devices get permanently deleted. false false 7
Wait time sensor reading sensorWaitTime Waiting time between the evaluation of the sensor values and the reading of the scenes in seconds. ATTENTION: digitalSTROM rule 8 and 9 require a waiting period of 1 minute. Values less than 60 seconds could affect the digitalSTROM system. false true 60

At the thing file, a manual configuration looks e.g. like

Bridge digitalstrom:dssBridge:dssBridge1 [ ipAddress="dss.local.",  userName="dssadmin", password=“dssadmin", sensorDataUpdateIntervall="180"]

digitalSTROM-Devices

The digitalSTROM-Device things have the following configuration parameter groups Device information and Sensor setup.

Device information

Each digitalSTROM-Device needs the device ID named dSID as a configuration parameter. The device ID is printed as a serial number at the digitalSTOM-Device and can also be found within the web-interface of the digitalSTROM-Server. Furthermore a supported digitalSTROM-Device has only informative parameter at this point. The following table shows all parameters:

Parameter Label Parameter ID Description Required Advanced
ID dSID The unique identifier of a digitalSTOM-device. true false
UID dSUID The unique identifier of a digitalSTOM-device with virtual devices. false false
Name deviceName The name of a digitalSTROM-Device. false false
Meter dSID meterDSID Identifier of the meter to which the device is connected. false false
Device hardware type hwInfo The hardware type from this digitalSTROM-Device. false false
Zone ID zoneID The digitalSTROM-Device is part of this zone. false false
Group ID's groups The digitalSTROM-Device is part of this user-defined or functional groups. false false
Output mode output mode The current digitalSTROM-Device output mode e.g. 22 = dimmable. false false
Functional color group funcColorGroup The current digitalSTROM-Device functional color group e.g. yellow = light. false false

Sensor setup

The GE and SW digitalSTROM-Devices usually have sensors to capture power consumption data. So these devices have the following parameters to read them out.

Parameter Label Parameter ID Description Required Advanced Default
Active power refresh priority activePowerRefreshPriority Sets the refresh priority for the active power sensor value. Can be never, low priority, medium priority or high priority. false false never
Electric meter refresh priority electricMeterRefreshPriority Sets the refresh priority for the electric meter sensor value. Can be never, low priority, medium priority or high priority. false false never
Output current refresh priority outputCurrentRefreshPriority Sets the refresh priority for the output current sensor value. Can be never, low priority, medium priority or high priority. false false never

digitalSTROM-Scenes

The digitalSTROM-Scenes can be defined with following parameters.

Parameter Label Parameter ID Description Required Advanced
Scene name sceneName The name of a digitalSTROM scene. false false
Zone ID or name zoneID The zone ID or zone name of the called scene. 0 or empty is broadcast to all. false false
Group ID or name groupID The group ID or group name of the called scene. 0 or empty is broadcast to all. false false
Scene ID or name sceneID The call scene ID or scene name, e.g. preset 1 for scene ID 5. Callable scenes are from 0 to 126. false false

The Scene-Thing-Type Named-Scene and Group-Scene have all parameters. The Apartment-Scene only has the parameters Scene name and Scene ID an the Zone-Scene has all parameters without Group ID or name.

Usually the discovery works reliably, so that a manual configuration is not needed.

However, at the thing file, a manual configuration looks e.g. like

Thing digitalstrom:GE:GE-KM200 [ dSID="´3504175fe0000000000043d4",  activePowerRefreshPriority="low", electricMeterRefreshPriority=“medium", outputCurrentRefreshPriority="high"]

Thing digitalstrom:GR:GR-KM200 [ dSID="3504175fe0000000000043d5"]

Channels

All devices support some of the following channels:

Channel Type ID Item Type Description supported device type
brightness Dimmer The brightness channel allows to dimm a light device. GE, SW
lightSwitch Switch The light switch channel allows to turn a light device on or off. GE, SW
combined2StageSwitch String The 2 stage light switch channel allows to turn both light devices on or off or switch only 1 of the both light devices on or off. SW-UMR200
combined3StageSwitch String The 3 stage light switch channel allows to turn both light devices on or off or switch both light devices separated from each other on or off. SW-UMR200
shade Rollershutter The shade control channel allows to control shade device e.g. a roller shutter or awnings. GR
shadeAngle Dimmer The slat control channel allows to control the relative slat position in percent of blinds. GR
generalDimm Dimmer The device power control channel allows to control the power of a device e.g. a ceiling fan. SW
generalSwitch Switch The device switch channel allows to turn a device on or off e.g. a HIFI-System. SW
generalCombined3StageSwitch String The 2 stage device switch channel allows to turn both relays of the device on or off or switch only 1 of the both relais on or off. SW-UMR200
generalCombined3StageSwitch String The 3 stage device channel allows to turn both relays of the device on or off or switch both relais of the device separated from each other on or off. SW-UMR200
activePower Number The active power channel indicates the current active power in watt (W) of the device. GE, SW
outputCurrent Number The output current channel indicates the current output current in ampere (A) of the device. GE, SW
electricMeter Number The electric meter channel indicates the current electric meter value in kilowatts hours (kWh) of the device. GE, SW
totalActivePower The total power consumption channel indicates the current consumption power in watt (W) of all connected circuits to the digitalSTROM-System. dssBridge
totalElectricMeter Number The total electric meter channel indicates the current electric meter value in killowatt hours of all connected circuits to the digitalSTROM-System. dssBridge
scene Switch The scene channel allows to call or undo a scene from digitalSTROM. Scene

Notes:

Channels with accepted command type increase and decrease:

  • digitalSTROM will only evaluate increase and decrease commands, if a scene was called before which turn the device on.

Blinds:

  • Increase, decrease and up, down commands of the shade channel changes the angle in digitalSTROM, too. If you want to set only the position, you have to set the value directly.
  • To protect the slats digitalSTROM changes the position by setting the angle, too, if the position is very high or low. So if you want to see the correct position, you have to send a refresh or stop command, if the blind is ready.

Full Example

demo.things:

Bridge digitalstrom:dssBridge:1 [ ipAddress="dss.local.",  userName="dssadmin", password="dssadmin", sensorDataUpdateIntervall=180] {
    GE GE-KM200 [ dSID="3504175fe0000000000043d4",  ActivePowerRefreshPriority="low", ElectricMeterRefreshPriority="medium", OutputCurrentRefreshPriority="high"]
    GR GR-KM200 [ dSID="3504175fe0000000000043d5"]
    namedScene scene1 [zoneID="0", groupID="0", sceneID="5"]
}

demo.items:

Dimmer Brightness { channel="digitalstrom:GE:GE-KM200-1:brightness" }
Number ActivePower { channel="digitalstrom:GE:GE-KM200-1:activePower" }
Number OutputCurrent { channel="digitalstrom:GE:GE-KM200-1:outputCurrent" }
Number ElectricMeter { channel="digitalstrom:GE:GE-KM200-1:electricMeter" }

Number TotalActivePower { channel="digitalstrom:dssBridge:dssBridge1:totalActivePower" }
Number TotalElectricMeter { channel="digitalstrom:dssBridge:dssBridge1:totalElectricMeter" }


Rollershutter Shade { channel="digitalstrom:GR:GR-KM200-1:shade" }

Switch Scene { channel="digitalstrom:namedScene:scene1:scene" }

demo.sitemap:

sitemap demo label="Main Menu"
{
    Frame {
        Slider item=Brightness 
        Switch item=Brightness
        Text item=ActivePower 
        Text item=OutputCurrent 
        Text item=ElectricMeter 
    }
    Frame {
        Text item=TotalActivePower 
        Text item=TotalElectricMeter 
    }
    Frame {
        Switch item=Scene 
    }
    Frame {
        Slider item=Shade 
    }
}