4512724 Dimmer 2 400W

This describes the Z-Wave device 4512724, manufactured by Namron with the thing type UID of namron_4512724_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

4512724 product image

The 4512724 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Z-wave in-wall dimmer v2 with power consumption monitoring. 400W 1 channel.

Inclusion Information

  1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).
  2.  Power on the in-wall dimmer and set it into inclusion mode. There are two methods to set the in-wall dimmer into inclusion mode:
    1. Repower on the dimmer, it will be set into inclusion mode automatically, and waiting to be included.
    2. Triple press the action button on the dimmer, it will set the dimmer into inclusion mode.

The connected light will stay solid on for 3 seconds to indicate successful inclusion.

Exclusion Information

There are two exclusion methods:

Method 1: Exclusion from the primary controller/gateway as follows:

  1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion).
  2. Triple press the action button, the dimmer will be set to exclusion mode, and waiting to be excluded, then the dimmer will be excluded from the network.

Method 2: Factory reset the dimmer will force it to be excluded from a network. (please refer to the part “Factory Reset” of this manual)

Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable.

General Usage Information

Channels

The following table summarises the channels available for the 4512724 -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (kVAh) meter_kvah meter_kvah Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Alarm (power) alarm_power alarm_power Energy Switch
Alarm (system) alarm_system alarm_system Switch

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kVAh)

Indicates the energy consumption (kVAh).

The meter_kvah channel is of type meter_kvah and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (system)

Indicates if a system alarm is triggered.

The alarm_system channel is of type alarm_system and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 19 configuration parameters available in the 4512724. Detailed information on each parameter can be found in the sections below.

Param Name Description
2 State after Power Failure State after Power Failure
3 Enable/disable to send the basic report Enable/disable to send the basic report
4 Default fade time Default fade time
5 Setting minimum Brightness value Setting minimum Brightness value
6 Setting maximum brightness value Setting maximum brightness value
7 Choose MOSFET driving type Choose MOSFET driving type
8 External switch type External switch type
9 Added/removed through external switch Added to and removed from a network through external switch
11 Wiring type Wiring type
12 Load type Load type
13 Enable/disable over current protection Enable/disable over current protection (over 2.1A for 20 seconds continuously)
14 Power automatic report absolute threshold Power automatic report absolute threshold
15 Power automatic report percentage threshold Power automatic report percentage threshold
21 Power metering automatic report time cycle Power metering automatic report time cycle
22 Energy metering automatic report time cycle Energy metering automatic report time cycle
23 Voltage metering automatic report time cycle Voltage metering automatic report time cycle
24 Current metering automatic report time cycle Current metering automatic report time cycle
31 Setting dimming curve Setting dimming curve
32 Setting startup brightness of the load Setting startup brightness of the load

Parameter 2: State after Power Failure

State after Power Failure Determines what the load stats should be after a device power failure. Values in the range 0 to 2 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Enable/disable to send the basic report

Enable/disable to send the basic report Enable/disable to send the basic report to the Lifeline when the load state changed.(When value set as 1, re-power on the dimmer, it will send basic report automatically) Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Default fade time

Default fade time Default fade time (unit is second, this value has the same function as Duration of Multilevel)

Valid value: 0~127 Values in the range 0 to 127 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Setting minimum Brightness value

Setting minimum Brightness value Setting minimum brightness value. Valid value: 0~50, the bigger the value is, the higher the loads minimum brightness is. Values in the range 0 to 50 may be set.

The manufacturer defined default value is 15.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Setting maximum brightness value

Setting maximum brightness value Setting maximum brightness value. Valid value: 0~100. Values in the range 0 to 100 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Choose MOSFET driving type

Choose MOSFET driving type Choose MOSFET driving type.

0 trailing edge
1 leading edge Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: External switch type

External switch type External switch type Values in the range 0 to 2 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Added/removed through external switch

Added to and removed from a network through external switch Added to and removed from a network through external switch (when enables this function, triple press the external switch within 1.5 seconds to be added to or removed from a network) Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 11: Wiring type

Wiring type Wiring type Values in the range 0 to 2 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_1 and is of type INTEGER. This is a read only parameter.

Parameter 12: Load type

Load type Load type Values in the range 0 to 3 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_1 and is of type INTEGER. This is a read only parameter.

Parameter 13: Enable/disable over current protection

Enable/disable over current protection (over 2.1A for 20 seconds continuously) Enable/disable over current protection (over 2.1A for 20 seconds continuously) Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Power automatic report absolute threshold

Power automatic report absolute threshold Power automatic report absolute threshold, unit is W. When power changes above the absolute threshold, immediately report current power value. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_14_2 and is of type INTEGER.

Parameter 15: Power automatic report percentage threshold

Power automatic report percentage threshold Power automatic report percentage threshold, unit is % When power changes above the percentage threshold, immediately report current power value Values in the range 0 to 100 may be set.

The manufacturer defined default value is 20.

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 21: Power metering automatic report time cycle

Power metering automatic report time cycle Power metering automatic report time cycle, unit is second. Valid time cycle value: 5~2678400, when set as 0, report function disabled. Values in the range 5 to 2678400 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_21_4 and is of type INTEGER.

Parameter 22: Energy metering automatic report time cycle

Energy metering automatic report time cycle Energy metering automatic report time cycle, unit is second. Valid time cycle value: 5~2678400, when set as 0, report function disabled. Values in the range 5 to 2678400 may be set.

The manufacturer defined default value is 1800.

This parameter has the configuration ID config_22_4 and is of type INTEGER.

Parameter 23: Voltage metering automatic report time cycle

Voltage metering automatic report time cycle Voltage metering automatic report time cycle, unit is second. Valid time cycle value: 5~2678400, when set as 0, report function disabled. Values in the range 5 to 2678400 may be set.

The manufacturer defined default value is 3600.

This parameter has the configuration ID config_23_4 and is of type INTEGER.

Parameter 24: Current metering automatic report time cycle

Current metering automatic report time cycle Current metering automatic report time cycle, unit is second. Valid time cycle value: 5~2678400, when set as 0, report function disabled. Values in the range 5 to 2678400 may be set.

The manufacturer defined default value is 3600.

This parameter has the configuration ID config_24_4 and is of type INTEGER.

Parameter 31: Setting dimming curve

Setting dimming curve

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_31_1 and is of type INTEGER.

Parameter 32: Setting startup brightness of the load

Setting startup brightness of the load Setting startup brightness of the load. Valid value: 0~99. 

Note: every time when turn on the load from OFF status, if the target brightness is lower than the startup brightness, the brightness will first go to the startup brightness value then fall down to the target brightness Values in the range 0 to 99 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_32_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 4512724 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

  1. When press and hold down “Reset” button for 10S to reset the dimmer, send "Device Reset Locally Notification CC" to associated devices of this group to report factory reset information.

  2. When load state changes, send "Basic Report CC" to associated devices of this group.

  3. When a load over current is detected, send "Over-current detected" to Lifeline.

  4. When a mains voltage drop is detected, send "Voltage drop/drift" to Lifeline.

  5. When over temperature is detected, send “Emergency shutoff status" to Lifeline.

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_TRANSPORT_SERVICE_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.