openhab-docs/_addons_bindings/sallegra1
Thomas Dietrich 826ef4abb4 Distinguish collections, improve update process (#514)
* Rename collection folders

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Change all occurences of addons and repos

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Add further corrections

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Remove temporary directories after processing

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Reduce addons menus, show current uncond.

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Fix typo

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Remove redundant addons from permalinks

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Sort UI menu entries correctly

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>

* Split maven command

Signed-off-by: Thomas Dietrich <Thomas.Dietrich@tu-ilmenau.de>
2017-09-22 21:05:09 +02:00
..
readme.md Distinguish collections, improve update process (#514) 2017-09-22 21:05:09 +02:00

readme.md

id label title type description source since install
sallegra Sallegra Sallegra - Bindings binding The Sallegra binding supports the Sallegra Dimmer DA-ET-4, Sallegra Relay R-ET-4 and Sallegra Input ADI-ET-8/8. https://github.com/openhab/openhab1-addons/blob/master/bundles/binding/org.openhab.binding.sallegra/README.md 1x manual

{% include base.html %}

Sallegra Binding

The Sallegra binding supports the Sallegra Dimmer DA-ET-4, Sallegra Relay R-ET-4 and Sallegra Input ADI-ET-8/8.

This binding syncs the openHAB status with the actual status on the Sallegra Module.

Prerequisites

A supported Sallegra device with the corresponding IP address, password and access to it via HTTP/Port 80.

Binding Configuration

This binding can be configured in the file services/sallegra.cfg.

Property Default Required Description
<modulename>.hostname Yes hostname or IP address of the Sallegra module
<modulename>.password Yes password of the Sallegra module

where <modulename> is a simple name you choose, like bedroom, to identify the specific module in items.

Item Configuration

The syntax is:

sallegra="<modulename>:<modulespecific>:<port>"

where:

  • <modulename> defines the name of the module. This is the name you earlier set for the module in the binding configuration.
  • <port> defines the hardware port on the Sallegra module. On dimmer and relay modules, this is exactly 1:1 the relay/dimmer port number you can find on the Device Sign. On the input module you have to use the complete string of the input. You can find them in the xml file of the input module.
  • <modulespecific> is a specific value to kind of specifiy the module. You should use the following strings according to the device:
Module <modulespecific>
R-ET-4 relay
ADI-ET-8/8 input
DA-ET-4 dimmer

Examples

You can use the following parameters in the item configuration to control a Sallegra module with the Openhab binding.

Switch Light_Livingroom   "Light_Livingroom"  { sallegra="livingroom:relay:1" }
String Input1             "Input1 [%s]"       { sallegra="inputmodule:input:DI8" }