--- id: dscalarm label: DSC Alarm title: DSC Alarm - Actions type: action description: "This bundle exposes openHAB rule extensions to be used with the DSC Alarm Binding (1.x binding). It allows the sending of DSC Alarm specific commands from within rules." source: https://github.com/openhab/openhab1-addons/blob/master/bundles/action/org.openhab.action.dscalarm/README.md since: 1x logo: images/addons/dscalarm.png install: manual --- {% include base.html %} # DSC Alarm Actions This bundle exposes openHAB rule extensions to be used with the DSC Alarm Binding (1.x binding). It allows the sending of DSC Alarm specific commands from within rules. ## Prerequisites The DSC Alarm Action bundle relies on the DSC Alarm Binding (1.x) being installed and configured. ## Actions * `sendDSCAlarmCommand(String command)` - sends a DSC Alarm command. * `sendDSCAlarmCommand(String command, String data)` - same as above but with command specific required data. The `command` parameter is a string numeric code. The following table shows which commands are supported: | DSC Alarm Command Code | Description | Data | Supported Interface | |------------------------|-------------|------|---------------------| | `000` | Poll | NONE | Envisalink, IT100 | | `001` | Status Report | NONE | Envisalink, IT100 | | `002` | Labels Request | NONE | IT100 | | `005` | Network Login | 1-6 Character - [Password] | Envisalink | | `008` | Dump Zone Timers | NONE | Envisalink | | `010` | Set Time and Date | NONE | Envisalink, IT100 | | `020` | Command Output Control | 2 Characters - [Partition # (1-8)][PGM # (1-4)] | Envisalink, IT100 | | `030` | Partition Arm Control - Away | 1 Character - [Partition # (1-8)] | Envisalink, IT100 | | `031` | Partition Arm Control - Stay | 1 Character - [Partition # (1-8)] | Envisalink, IT100 | | `032` | Partition Arm Control - No Entry Delay | 1 Character - [Partition # (1-8)] | Envisalink, IT100 | | `033` | Partition Arm Control - With User Code | 5-7 Characters - [Partition # (1-8)][User Code (4-6)] | Envisalink, IT100 | | `040` | Partition Disarm Control - With User Code | 5-7 Characters - [Partition # (1-8)][User Code (4-6)] | Envisalink, IT100 | | `055` | Time Stamp Control | 1 Character - [On/Off (1,0)] | Envisalink, IT100 | | `056` | Time/Date Broadcast Control | 1 Character - [On/Off (1,0)] | Envisalink, IT100 | | `057` | Temperature Broadcast Control | 1 Character - [On/Off (1,0)] | Envisalink, IT100 | | `058` | Virtual Keypad Control | 1 Character - [On/Off (1,0)] | IT100 | | `060` | Trigger Panic Alarm | 1 Character - [1=Fire, 2=Ambulance, 3=Police] | Envisalink, IT100 | | `070` | Single Keystroke | 1 Character - [Single ASCII Character] | Envisalink, IT100 | | `071` | Keystroke String | 1-6 Characters - [1-6 ASCII Character String] | Envisalink | | `074` | Keep Alive | 1 Character - [Partition # (1-8)] | Envisalink | | `200` | Code Send | 4-6 Characters - [User Code (4-6)] | Envisalink, IT100 | ## Examples To invoke the action see the examples below: Add an item to your items file such as a switch: ``` Switch PollCommand "Send a poll command to the DSC Alarm System" ``` The following rule will trigger whenever the switch is turned ON: ``` rule "PollCommand" when Item PollCommand received command ON then sendDSCAlarmCommand("000") end ``` Again add an item to your items file: ``` Switch BypassZone1 "Bypass Zone 1" ``` This rule triggers when the switch is turned ON: ``` rule "BypassZone1" when Item BypassZone1 received command ON then sendDSCAlarmCommand("071","*101#") end ```