--- layout: documentation title: ZV2835RAC - ZWave --- {% include base.html %} # ZV2835RAC Knob Smart Dimmer This describes the Z-Wave device *ZV2835RAC*, manufactured by *[Sunricher](www.sunricher.com)* with the thing type UID of ```sunricher_zv2835rac_00_000```. This version of the device is limited to firmware versions below 1.23 The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![ZV2835RAC product image](https://opensmarthouse.org/zwavedatabase/1177/image/) The ZV2835RAC supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview The knob smart dimmer is a Z-Wave device designed to work with various types of light sources. It may be connected to two-wire or three-wire configuration so it can operate with or without neutral lead. The dimmer can switch or dim connected light source either through Z-Wave devices or through the rotary knob directly. The smart dimmer is equipped with an algorithm of smart light source detection which makes configuration easier and ensures high compatibility of the device. It may be used as a switch with non-dimmable light sources (in 3-wire connection). Main Features: * Advanced microprocessor control, * Implemented algorithm of smart light source detection, * Auto-adjustment of the appropriate control mode to connected load, * Active power and energy metering functionality, * Soft start function, * Memory of the last lighting level settings It operates under the following loads: * Conventional incandescent and HV halogen light sources * ELV halogen lamps and dimmable LED bulbs (with electronic transformers) * MLV halogen lamps (with ferromagnetic transformers) * Dimmable LED bulbs * Dimmable compact fluorescent CFL tube lamps It can be configured to use “Trailing edge” or “Leading edge” to control following load types: * "Trailing edge" for resistive loads * "Trailing edge" for capacitive loads * "Leading edge" for inductive loa ### Inclusion Information There are two methods to set the dimmer into inclusion mode: 1. Repower on the dimmer, it will be set into inclusion mode automatically, and waiting to be included. 2. Triple press reset button on the dimmer, it will set the dimmer into inclusion mode. ### Exclusion Information There are two exclusion methods: Method 1: Exclusion from the primary controller/gateway as follows: 1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion). 2. Triple press reset button, the dimmer will be set to exclusion mode, and waiting to be excluded, then the dimmer will be excluded from the network. Method 2: Factory reset the dimmer will force it to be excluded from a network. Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable. Factory Reset: Press and hold down the reset button for over 10 seconds, the dimmer will be reset to factory defaults, the load brightness will be restored to 50% and will flash slowly. ### General Usage Information ## Channels The following table summarises the channels available for the ZV2835RAC -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer | | Scene Number | scene_number | scene_number | | Number | | Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number | | Electric meter (amps) | meter_current | meter_current | Energy | Number | | Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number | | Electric meter (watts) | meter_watts | meter_watts | Energy | Number | | Alarm (power) | alarm_power | alarm_power | Energy | Switch | | Alarm (system) | alarm_system | alarm_system | | Switch | ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel is of type ```switch_dimmer``` and supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. ### Electric meter (volts) Indicates the instantaneous voltage. The ```meter_voltage``` channel is of type ```meter_voltage``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) Indicates the instantaneous current consumption. The ```meter_current``` channel is of type ```meter_current``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel is of type ```meter_kwh``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel is of type ```meter_watts``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Alarm (power) Indicates if a power alarm is triggered. The ```alarm_power``` channel is of type ```alarm_power``` and supports the ```Switch``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Alarm (system) Indicates if a system alarm is triggered. The ```alarm_system``` channel is of type ```alarm_system``` and supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ## Device Configuration The following table provides a summary of the 20 configuration parameters available in the ZV2835RAC. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 2 | Saving load state | Saving load state before power failure | | 3 | Basic report | Send the basic report to the Lifeline when the load state changed | | 4 | Default fade time | Default fade time | | 5 | Minimum brightness | Minimum brightness | | 6 | Maximum brightness | Maximum brightness | | 7 | MOSFET driving type | MOSFET driving type | | 8 | Step setting | Step setting of the knob | | 9 | Add and remove through switch | Add and remove through switch | | 10 | Load detection | Load detection | | 11 | Wiring type | Wiring type | | 12 | Load type | Load type | | 13 | Overcurrect Protection | Overcurrect Protection | | 14 | Power absolute threshold | Power automatic report absolute threshold | | 15 | Power percentage threshold | Power automatic report percentage threshold | | 21 | Power report cycle | Power metering automatic report time cycle | | 22 | Energy report cycle | Energy metering automatic report time cycle | | 23 | Voltage report cycle | Voltage metering automatic report time cycle | | 24 | Current report cycle | Current metering automatic report time cycle | | 31 | Dimming curve | Dimming Curve | | 32 | Startup brightness | Startup brightness | ### Parameter 2: Saving load state Saving load state before power failure Info: Saving load state before power failure 0 - shutoff load 1 - turn on load 2 - save load state before power failure The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Shutoff load | | 1 | turn on load | | 2 | Save load state | The manufacturer defined default value is ```2``` (Save load state ). This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Basic report Send the basic report to the Lifeline when the load state changed Info: Enable/disable to send the basic report to the Lifeline when the load state changed(When value set as 1, re-power on the dimmer, it will send Basic report automatically) 0 - Disable to send Basic report 1 - Enable to send Basic report The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable Basic report | | 1 | Enable Basic report | The manufacturer defined default value is ```1``` (Enable Basic report). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Default fade time Default fade time Default fade time (unit is second, this value has the same function as Duration of Multilevel) 0: Instantly 1-127: 1 to 127 seconds in 1 second resolution Values in the range 0 to 127 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: Minimum brightness Minimum brightness Values in the range 0 to 50 may be set. The manufacturer defined default value is ```15```. This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 6: Maximum brightness Maximum brightness Values in the range 0 to 100 may be set. The manufacturer defined default value is ```100```. This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Parameter 7: MOSFET driving type MOSFET driving type MOSFET driving type: 0 - trailing edge 1 - leading edge The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Trailing edge | | 1 | Leading edge | The manufacturer defined default value is ```0``` (Trailing edge). This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: Step setting Step setting of the knob Setting step of the knob Corresponding dimming stepping level for each rotation of the knob (a full dimming stepping level is 99) Valid value: 1-50 Values in the range 1 to 50 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 9: Add and remove through switch Add and remove through switch Added to and removed from a network through external switch (when enables this function, triple press the external switch within 1.5 seconds to be added to or removed from a network) 0 - disable 1 - enable The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable | | 1 | Enable | The manufacturer defined default value is ```0``` (Disable). This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Parameter 10: Load detection Load detection Enable/disable to detect load after re-power on (detect load type, minimum brightness, maximum brightness) 0 - disable 1 - enable to detect every time after re-power on 2 - enable to detect only after first re-power on Note: When the device does not belong to any network, load detection will be enabled every time after re-power on. When the device has already been added to a network, load detection will be disabled. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable | | 1 | Enable after each power on | | 2 | Enable after first power on | The manufacturer defined default value is ```0``` (Disable). This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 11: Wiring type Wiring type Wiring type 0 - unknown 1 - 2 Wire With No Neutral 2 - 3 Wire With Neutral The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Unknown | | 1 | 2 Wire with no Neutral | | 2 | 3 Wire with Neutral | The manufacturer defined default value is ```0``` (Unknown). This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. This is a read only parameter. ### Parameter 12: Load type Load type Load type 0 - unknown 1 - resistive 2 - inductive 3 - capacitive The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Unknown | | 1 | Resistive | | 2 | Inductive | | 3 | Capacitive | The manufacturer defined default value is ```0``` (Unknown). This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. This is a read only parameter. ### Parameter 13: Overcurrect Protection Overcurrect Protection Enable/disable over current protection (over 3.2A for 20 seconds continuously) 0 – disable 1 – enable The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable | | 1 | Enable | The manufacturer defined default value is ```1``` (Enable). This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 14: Power absolute threshold Power automatic report absolute threshold Power automatic report absolute threshold, unit is W When power changes above the absolute threshold, immediately report current power value Values in the range 0 to 600 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_14_2``` and is of type ```INTEGER```. ### Parameter 15: Power percentage threshold Power automatic report percentage threshold Power automatic report percentage threshold, unit is % When power changes above the percentage threshold, immediately report current power value Values in the range 0 to 100 may be set. The manufacturer defined default value is ```20```. This parameter has the configuration ID ```config_15_1``` and is of type ```INTEGER```. ### Parameter 21: Power report cycle Power metering automatic report time cycle Power metering automatic report time cycle, unit is second Valid time cycle value: 5~2678400 Default is 600 seconds (10 minutes) Values in the range 5 to 2678400 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_21_4``` and is of type ```INTEGER```. ### Parameter 22: Energy report cycle Energy metering automatic report time cycle Energy metering automatic report time cycle, unit is second Valid time cycle value: 5~2678400 Default is 1800 seconds (30 minutes) Values in the range 5 to 2678400 may be set. The manufacturer defined default value is ```1800```. This parameter has the configuration ID ```config_22_4``` and is of type ```INTEGER```. ### Parameter 23: Voltage report cycle Voltage metering automatic report time cycle Voltage metering automatic report time cycle, unit is second Valid time cycle value: 5~267840 Values in the range 5 to 2678400 may be set. The manufacturer defined default value is ```3600```. This parameter has the configuration ID ```config_23_4``` and is of type ```INTEGER```. ### Parameter 24: Current report cycle Current metering automatic report time cycle Current metering automatic report time cycle, unit is second Valid time cycle value: 5~2678400 Values in the range 5 to 2678400 may be set. The manufacturer defined default value is ```3600```. This parameter has the configuration ID ```config_24_4``` and is of type ```INTEGER```. ### Parameter 31: Dimming curve Dimming Curve The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Linear dimming | | 1 | Logarithmic dimming | The manufacturer defined default value is ```0``` (Linear dimming). This parameter has the configuration ID ```config_31_1``` and is of type ```INTEGER```. ### Parameter 32: Startup brightness Startup brightness Setting startup brightness of the load Valid value: 0~99 Note: every time when turn on the load from OFF status, if the target brightness is lower than the startup brightness, the brightness will first go to the startup brightness value then fall down to the target brightness Values in the range 0 to 99 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_32_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The ZV2835RAC supports 2 association groups. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 5 nodes. ### Group 2: Launch 1 Association group 2 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| Linked to BASIC| | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V8| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_SECURITY_V1| | ### Documentation Links * [Manual](https://opensmarthouse.org/zwavedatabase/1177/reference/ROBB-SMARRT-Z-wave-dimmer-manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1177).