--- layout: documentation title: PAT02-B - ZWave --- {% include base.html %} # PAT02-B Z-Wave room sensor This describes the Z-Wave device *PAT02-B*, manufactured by *[Philio Technology Corp](http://www.philio-tech.com/)* with the thing type UID of ```philio_pat02b_00_000```. The device is in the category of *Sensor*, defining Device used to measure something. ![PAT02-B product image](https://opensmarthouse.org/zwavedatabase/533/image/) The PAT02-B supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices. The PAT02-B does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the *Wakeup Information* section below for further information. ## Overview The flood multisensor PAT02 has flood, temperature and humidity, 3 sensors function in one, based on Z-WaveTM technology ### Inclusion Information Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode. ### Exclusion Information Pressing tamper key three times within 1.5 seconds to enter the exclusion mode ### Wakeup Information The PAT02-B does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device. Press the tamper key once. The device will wake-up 10 seconds. ## Channels The following table summarises the channels available for the PAT02-B -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Binary Sensor | sensor_binary | sensor_binary | | Switch | | Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature | | Sensor (relative humidity) | sensor_relhumidity | sensor_relhumidity | Humidity | Number | | Alarm (burglar) | alarm_burglar | alarm_burglar | Door | Switch | | Battery Level | battery-level | system.battery_level | Battery | Number | ### Binary Sensor Indicates if a sensor has triggered. The ```sensor_binary``` channel is of type ```sensor_binary``` and supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | ON | Triggered | | OFF | Untriggered | ### Sensor (temperature) Indicates the current temperature. The ```sensor_temperature``` channel is of type ```sensor_temperature``` and supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Sensor (relative humidity) Indicates the current relative humidity. The ```sensor_relhumidity``` channel is of type ```sensor_relhumidity``` and supports the ```Number``` item and is in the ```Humidity``` category. This is a read only channel so will only be updated following state changes from the device. ### Alarm (burglar) Indicates if the burglar alarm is triggered. The ```alarm_burglar``` channel is of type ```alarm_burglar``` and supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```system.battery-level``` channel is of type ```system.battery-level``` and supports the ```Number``` item and is in the ```Battery``` category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%. ## Device Configuration The following table provides a summary of the 8 configuration parameters available in the PAT02-B. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 5 | Operation Mode | set Operation Mode using bit to control | | 7 | Customer Function | Customer Function switch using bit control | | 10 | Auto Report Battery Time | The interval time for auto reporting the battery level. | | 13 | Auto Report Temperature Time | The interval time for auto reporting the temperature state. | | 14 | Auto Report Humidity Time | The interval time for auto reporting the humidity state. | | 20 | Auto Report Tick Interval | The interval time for auto report each tick. | | 21 | Temperature Differential Report | The temperature differential to report. | | 23 | Humidity Differential Report | The humidity differential to report. | | | Wakeup Interval | Sets the interval at which the device will accept commands from the controller | | | Wakeup Node | Sets the node ID of the device to receive the wakeup notifications | ### Parameter 5: Operation Mode set Operation Mode using bit to control set Operation Mode using bit to control * Bit 0: Reserve * Bit 1: Reserve * Bit 2: Reserve * Bit 3: Setting temperature scale * 0: Fahrenheit * 1: Celsius * Bit 4: Reserve * Bit 5: Reserve * Bit 6: Reserve * Bit 7: Reserve Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 7: Customer Function Customer Function switch using bit control Customer Function switch using bit control * Bit 0: Reserve * Bit 1: Reserve * Bit 2: Reserve * Bit 3: not applicable for this device variant, set to 0 * Bit 4: Notification Type * 0: Using Notification Report * 1: Using Sensor Binary Report * Bit 5: Disable Multi CC in auto report * 0: Enable * 1: Disable * Bit 6: not applicable for this device variant, set to 0 * Bit 7: Reserve Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 10: Auto Report Battery Time The interval time for auto reporting the battery level. The interval time for auto reporting the battery level. * 0 = Turn off auto report battery. * 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 1 to 127 may be set. The manufacturer defined default value is ```12```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 13: Auto Report Temperature Time The interval time for auto reporting the temperature state. The interval time for auto reporting the temperature state. * 0 = Turn off auto report temperature. * 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 1 to 127 may be set. The manufacturer defined default value is ```12```. This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 14: Auto Report Humidity Time The interval time for auto reporting the humidity state. The interval time for auto reporting the humidity state. * 0 = Turn off auto report. * 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_14_1``` and is of type ```INTEGER```. ### Parameter 20: Auto Report Tick Interval The interval time for auto report each tick. The interval time for auto report each tick. Units of one minute. Setting configuration will affect configuration no. 10, 13, 14 and 15. * Caution1: Setting to 0 means turn off all auto report function. * Caution2: The value is unsigned byte. Values in the range 0 to 255 may be set. The manufacturer defined default value is ```30```. This parameter has the configuration ID ```config_20_1``` and is of type ```INTEGER```. ### Parameter 21: Temperature Differential Report The temperature differential to report. The temperature differential to report. * The unit is Fahrenheit. * Enable this function the device will detect every 10 seconds. Values in the range 0 to 127 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_21_1``` and is of type ```INTEGER```. ### Parameter 23: Humidity Differential Report The humidity differential to report. The humidity differential to report. * The unit is percentage. * Enable this function the device will detect every 10 seconds. Values in the range 0 to 60 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_23_1``` and is of type ```INTEGER```. ### Wakeup Interval The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications. This setting is defined in *seconds*. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances. Note that this setting does not affect the devices ability to send sensor data, or notification events. This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```. ### Wakeup Node When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact. This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The PAT02-B supports 2 association groups. ### Group 1: Reports Association group 1 supports 7 nodes. ### Group 2: Light Control Association group 2 supports 7 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_BINARY_V2| Linked to BASIC| | COMMAND_CLASS_SENSOR_MULTILEVEL_V5| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V4| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_WAKE_UP_V2| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CMD_V1| | | COMMAND_CLASS_SECURITY_V1| | ### Documentation Links * [Philio PAT02 A/B/C manual](https://opensmarthouse.org/zwavedatabase/533/reference/philio---pat02---manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/533).